U N I V E R S A L R E M O T E C O N T R O L | L Z R - I 3 0 / S 6 0 0
L Z R - I 3 0 / S 6 0 0 PA R A M E T E R S
A - NO
P - NC
A - NO
P - NC
P - NC
A - NO
P - NC
A - NO
R1
R2
A = active
P = passive
NO = normally open
NC = normally closed
O U T P U T C O N F I G U R AT I O N
M I N I M U M O B J E C T S I Z E
The distances between the curtains depends on the mounting height and side.
When mounted on the left, the distance between curtain C1 and curtain C4 is approximately 4 in. for every 3 ft (mounting height).
EXAMPLE:
At 15 ft. mounting height, the distance between C1 and C4 is 20 in.
L Z R T I P S
T H E L Z R - I 3 0 R E Q U I R E S 1 0 - 3 5 V C L E A N D C P O W E R
( N O N - R E C T I F I E D )
A F T E R 3 0 M I N U T E S , T H E S E N S O R L O C K S A C C E S S T O
T H E R E M O T E C O N T R O L S E S S I O N . P O W E R C Y C L E T H E
S E N S O R T O R E C O N F I G U R E .
A B E A U N I V E R S A L R E M O T E I S R E Q U I R E D T O
C O N F I G U R E T H E L Z R - I 3 0 .
U N I V E R S A L R E M O T E C O N T R O L T I P S
T O Q U E S T I O N A PA R A M E T E R , P R E S S
A F T E R U N L O C K I N G A N D C H O O S I N G A
PA R A M E T E R . C O U N T T H E L E D F L A S H E S .
C O N S I D E R U S I N G A N A C C E S S C O D E
TO SET AN ACCESS CODE:
TO DELETE AN ACCESS CODE:
V I R T U A L P U S H P L AT E :
F A C T O RY D E F A U LT S :
A LWAY S F I N I S H A N A D J U S T M E N T S E S S I O N
B Y L A U N C H I N G A S E T U P :
T O T U R N T H E L E D s O N / O F F :
F O R V I S I B L E L A S E R B E A M S :
T O C H A N G E O R Q U E S T I O N A PA R A M E T E R ,
S TA R T B Y P R E S S I N G T H E A N D F I N I S H
T H E S E S S I O N B Y P R E S S I N G
# O F A C T I V E D E T E C T I O N C U R TA I N S
Increase in case of snow, dead leaves, etc.
U N C O V E R E D Z O N E
2 i n
4 i n
6 i n
8 i n
10 i n
M O U N T I N G S I D E
left
right
left
center
WITH BACKGROUND
WITHOUT BACKGROUND
right
indoor
outdoor
low
outdoor
med
outdoor
high
Choose between environment or object.
I M M U N I T Y F I LT E R
FOR CRITICAL ENVIRONMENTS
(RAIN, SNOW, FOG)
indoor
outdoor
low
outdoor
med
outdoor
high
FOR CRITICAL OBJECTS
(BLACK CARS)
O F F
3 i n
4 i n
6 i n
8 i n
O U T P U T A C T I VAT I O N D E L AY
O F F
100ms
200ms
300ms
400ms
500ms
600ms
700ms
800ms
900ms
The relays are triggered when the detection duration ≥ the selected time.
CURTAIN
C1 C2 C3 C4
CURTAIN IS INACTIVE ON BOTH FIELDS
CURTAIN IS ACTIVE ON OPTIONAL FIELD
CURTAIN IS ACTIVE ON SAFETY FIELD
CURTAIN IS ACTIVE ON BOTH FIELDS
C1 + C2 ARE ACTIVE ON SAFETY FIELD
C3 + C4 ARE ACTIVE ON OPTIONAL FIELD
C1 IS ACTIVE ON BOTH FIELDS
C2 + C3 ARE ACTIVE ON SAFETY FIELD
C4 IS INACTIVE
ALL CURTAINS ARE ACTIVE ON BOTH FIELDS
E X A M P L E C O N F I G U R AT I O N S
O P T I O N A L F I E L D W I D T H
O P T I O N A L F I E L D H E I G H T
S A F E T Y F I E L D W I D T H
S A F E T Y F I E L D H E I G H T