SAFETY SENSOR FOR REVOLVING DOORS

User’s Guide for product version 0202 and higher
See product label for serial number

Содержание LZR-FLATSCAN REV-LZ

Страница 1: ...N 16005 E N A B L E S A C C O R D A N C E W I T H E R L A U B T Z E R T I F I Z I E R U N G N A C H DIN 18650 E N A B L E S A C C O R D A N C E W I T H EN SAFETY SENSOR FOR REVOLVING DOORS User s Guide for product version 0202 and higher See product label for serial number ...

Страница 2: ...lified personnel may install and setup the sensor The warranty is invalid if unauthorized repairs are made or attempted by unauthorized personnel Always test the good functioning of the installation before leaving the premises The door control unit and the door cover profile must be correctly earthed MAINTENANCE TIPS SAFETY TIPS Avoid vibrations Do not cover the laser window Avoid moving objects a...

Страница 3: ...liance with 5 9 3 of EN 16005 depending on the analysis conducted by the door manufacturer LED SIGNALS DESCRIPTION 1 cover 2 push button 3 DIP switch 4 spare connector not used 5 connector 6 angle adjustment screw 7 plug 8 clamp 9 cap and screws flexible kit 10 flexible tube 11 lock screw 12 laser head Relay 2 Relay 1 LED flashes LED flashes slowly LED is off LED flashes x times LED flashes red gr...

Страница 4: ...y When mounting the base make sure the sensor will not hinder the door movement If the sensor isn t correctly positioned it could be crushed during the opening of the door Using a pencil mark the position of the holes to drill into the door frame You can also use the inner surface of the base to fasten the screws Remove the base and pre drill the holes where marked ...

Страница 5: ...Soften the edges using a sheet of sandpaper Take the cable and pass it through the hole Position the cable in the notch of the base and make sure it is firmly fixed Take the sensor and remove the cover put your finger in the hole and pull firmly towards you in one movement Pass the cable through the hole on the back of the sensor and fasten the sensor on the base by sliding it downwards We provide...

Страница 6: ...d within the notch to avoid crushing them with the cover Close the sensor which will not be connected to the door controller using a plug Fasten the lock screw firmly Take the flexible tube and determine how long it should be in order to reach the door controller Cut the surplus to avoid undesired detections caused by the flexible tube ...

Страница 7: ... cable through the flexible tube Connect the plug to the white connector Make a loop with the wires of the power cable and pass them through the notch as indicated Use the other part of the cable to block the wires Take the clamp to fix the flexible tube to the sensor Fasten the 2 screws firmly in order to avoid pulling out the cable Tighten the other side of the flexible tube using the cable cap ...

Страница 8: ...green slowly next the red no need to do anything during this process Make sure you re outside of the detection field wait until the LED is off the teach in is completed Custom Mode The LED starts to flash red then green slowly then move your hand to define the detection field as your request next LED flashes red Make sure you re outside of the detection field wait until the LED is off the teach in...

Страница 9: ...in the notch and pull upwards until the cover comes loose FINAL STEPS If necessary adjust the tilt angle of the laser curtain by turning the tilt angle adjustment screw from 2 to 10 The service mode deactivates the safety detection during 15 minutes and can be useful during an installation a mechanical teach in of the door or maintenance work To enter the service mode push on the button for at lea...

Страница 10: ...ETECTION DIP SWITCH SETTINGS OPTIONAL After changing a DIP switch the orange LED flashes A LONG push on the push button confirms the settings ORANGE OFF GREEN In order to change these settings by remote control adjust DIP switch 4 to ON Switch to CRITICAL when external disturbances are likely to cause unwanted detections min obj size immunity and uncovered zone are increased Switch to OFF when the...

Страница 11: ...llation ANTIMASKING BACKGROUND GENERAL ANTIMASKING BACKGROUND Antimasking protective function which detects an unwanted object nearby the laser window masking the vision field Background reference point in the detection field of the sensor If no background is present switch to off IMMUNITY FILTER Increase to filter out external disturbances The reaction time increases significantly between value 5...

Страница 12: ...he red LED flashes quickly after unlocking you need to enter an access code from 1 to 4 digits If you do not know the access code cut and restore the power supply During 1 minute you can access the sensor without introducing any access code field width 2 35 m To end an adjustment session always lock the sensor Enter the existing code x number of flashes value of the parameter full reset partial re...

Страница 13: ...13 TWO WING REVOLVING DOOR THREE WING REVOLVING DOOR DETECTION FIELDS DOOR WING SAFETY Typ object size 10 cm at 4 m UNCOVERED ZONE Adjustable by remote control factory value 10 cm ...

Страница 14: ... carefully with a damp and clean microfibre cloth if necessary attention the surface of the laser window is delicate 3 Launch a new teach in 4 Switch DIP 2 to off critical environment The sensor does not react at power on Inverted power supply Check wiring green brown Faulty cable Replace cable Faulty sensor Replace sensor The sensor does not react when powered Test error Check voltage between red...

Страница 15: ...between interface card and laser head The ORANGE LED flashes 4 x every 3 seconds The sensor does not see its background Switch DIP 3 to off deactivates background Something close to the sensor is masking part of the detec tion field 1 Make sure the laser window is not scratched If it is replace sensor 2 Remove all masking elements insects spider web flexible tube window protection 3 Verify if the ...

Страница 16: ...g base 7 mm Material Colour PC ASA Black Aluminum White Tilt angles 2 to 10 without mounting base Protection degree IP54 IEC EN 60529 Temperature range 30 C to 60 C if powered Humidity 0 95 non condensing Vibrations 2 G Compliance EN 16005 Chapter 4 6 8 test body CA DIN 18650 1 Chapter 5 7 4 test body CA EN 12978 EN ISO 13849 1 PL d CAT2 IEC EN 60825 1 IEC EN 61000 6 2 IEC EN 61000 6 3 IEC EN 6150...