background image

LZR

®

-FLATSCAN 3D SW

E

R

L

A

U

B

T

 

Z

E

R

T I

F I Z

I E R U N G

 

N

A

C

H

EN 1

600

5

E

N

A

B L E

S

 

A C C

O R

D

A

N

C

E

 

W

I

T

H

E

R

L

A

U

B

T

 

Z

E

R

T I

F I Z

I E R U N G

 

N

A

C

H

DIN 1

865

0

E

N

A

B L E

S

 

A C C

O R

D

A

N

C

E

 

W

I

T

H

EN

SAFETY SENSOR 

FOR AUTOMATIC SWING DOORS

User’s Guide for software version SW 0100 and higher 

(refer to tracking label on product)

Содержание LZR-FLATSCAN 3D SW

Страница 1: ...5 E N A B L E S A C C O R D A N C E W I T H E R L A U B T Z E R T I F I Z I E R U N G N A C H DIN 18650 E N A B L E S A C C O R D A N C E W I T H EN SAFETY SENSOR FOR AUTOMATIC SWING DOORS User s Guide for software version SW 0100 and higher refer to tracking label on product ...

Страница 2: ...responsible for incorrect installations or inappropriate adjustments of the sensor Only trained and qualified personnel may install and setup the sensor The warranty is invalid if unauthorized repairs are made or attempted by unauthorized personnel Always test the good functioning of the installation before leaving the premises The door control unit and the door cover profile must be correctly ear...

Страница 3: ...ioning aids 15 mounting base 16 MAIN SECONDARY cable 17 power cable Relay 2 Relay 3 FLATSCAN 3D SW only Relay 1 LED flashes LED flashes slowly LED is off LED flashes x times LED flashes red green LED flashes quickly Calculation in progress Exit the zone and wait The LZR FLATSCAN 3D SW and LZR FLATSCAN SW are safety sensors for automatic swing doors based on laser technology They secure the moving ...

Страница 4: ...rface of the base to fasten the screws When mounting the base make sure the sensor will not hinder the door movement If the sensor isn t correctly positioned it could be crushed during the opening of the door Remove the base and pre drill the holes where marked The FLATSCAN 3D SW can be paired with another FLATSCAN 3D SW or a FLATSCAN SW The installation steps are identical for both product versio...

Страница 5: ...e the MAIN SECONDARY cable and pass it through the hole Position the cable in the notch of the base and make sure it is firmly fixed Sensor connected to other module SECONDARY module Pass the cable through the hole on the back of the sensor and fasten the sensor on the base Connect the black plug to the black connector Make sure that all wires are safely tucked within the notch to avoid crushing t...

Страница 6: ...he flexible tube Pass the power cable through the flexible tube Connect the white plug to the white connector Make a loop with the wires of the power cable and pass them through the notch as indicated Use the other part of the cable to block the wires Take the clamp to fix the flexible tube to the sensor Fasten the 2 screws firmly in order to avoid pulling out the cable Tighten the other side of t...

Страница 7: ...CH 1 After changing a DIP switch the orange LED flashes A LONG push on the push button confirms the settings Afterwards a number of green flashes x indicates the number of connected modules Make sure the setting of DIP 1 is correct on all modules according to the door side GREEN RELAY 1 STOP impulse on the opening side of the door RELAY 2 REOPENING impulse on the closing side of the door 3 sec R3 ...

Страница 8: ...epeat this on the other MAIN module 2 Wait until all main modules flash green Position yourself in front of the door and stretch out your arm in front of you Make an up and down movement at closing edge level in order to mark the limit of the detection zones The LED flashes red while calculating the width of the door wings 3 Wait until all main modules flash green again The Flatscan 3D SW will ope...

Страница 9: ...oller with the cable provided 10 strands VIRTUAL OPENING BUTTONS FLATSCAN 3D SW only Close the cover starting on the narrow side Do not hesitate to push To open the sensor again position a screwdriver in the notch and pull until the cover comes loose OR FINAL STEPS CLOSING OPENING The FLATSCAN 3D SW provides an edge zone safeguarding the leading edge of the door leaf while the door is closing The ...

Страница 10: ...e settings Afterwards a number of green flashes x indicates the number of connected modules ORANGE OFF GREEN DIP 4 HINGE ZONE Switch to CRITICAL when external disturbances are likely to cause unwanted detections min obj size immunity and uncovered zone are increased Switch to OFF when the hinge area does not need to be secured and objects can cause unwanted detections The actual dimensions depend ...

Страница 11: ... on application and installation NO POWER NO DETECTION DETECTION In order to change these settings by remote control adjust DIP switch 2 to ON In order to change these settings by remote control adjust DIP switch 3 to ON OFF OFF ON OFF ON OFF ANTIMASKING BACKGROUND ON ON 1 curtain 2 curtains 3 curtains 4 curtains MAN OFF OPENING FIELD 1 curtain 2 curtains 3 curtains 4 curtains only available with ...

Страница 12: ...ted modules ORANGE OFF GREEN DIP 3 BACKGROUND DIP 4 HINGE ZONE Make a risk analysis to check if the environment requires an additional mechanical protection in the hinge area Switch to CRITICAL when external disturbances are likely to cause unwanted detections min obj size immunity and uncovered zone are increased Switch to OFF when there is no background glass floor footbridge Switch to OFF when ...

Страница 13: ...indow masking the vision field Background reference point in the detection field of the sensor If no background is present switch to off Increase to filter out external disturbances The reaction time increases significantly between value 5 and 9 Increase in case of snow dead leaves etc measured in specific conditions and dependant on application and installation ON ON low high NO POWER NO DETECTIO...

Страница 14: ...ng you need to enter an access code from 1 to 4 digits If you do not know the access code cut and restore the power supply During 1 minute you can access the sensor without introducing any access code field width 2 35 m To end an adjustment session always lock the sensor Enter the existing code x number of flashes value of the parameter It is recommended to use a different access code for each mod...

Страница 15: ...D SW FLATSCAN SW DETECTION FIELDS HINGE ZONE SAFETY DOOR WING SAFETY UNCOVERED ZONE Adjustable by remote control factory value 10 cm Check the detection fields using our online sizer tool https eu beasensors com sizer flatscan ...

Страница 16: ...r 4 Switch DIP 2 to off critical environment The sensor does not react at power on Inverted power supply Check wiring green brown Faulty cable Replace cable Faulty sensor Replace sensor The sensor does not react when powered Test error Check voltage between red and blue wires Press the push button during at least 3 seconds to exit the service mode Opening function does not react at power on The op...

Страница 17: ...close to the sensor is masking part of the detection field 1 Make sure the laser window is not scratched If it is replace sensor 2 Remove all masking elements insects spider web flexible tube window protection 3 Verify if the laser window is dirty and clean it with compressed air Then wipe it carefully with a damp and clean microfibre cloth if necessary attention the surface of the laser window is...

Страница 18: ...18 NOTES ...

Страница 19: ...19 NOTES ...

Страница 20: ... spots 1 7 between spots Curtain 4 40 spots 2 5 between spots Door wing safety 70 spots 1 3 between spots Hinge zone safety 100 spots 0 2 between spots Typ min object size 2cm 4m in curtain C1 Door wing safety 10 cm 4m in proportion to object distance DIP 2 ON Hinge zone safety 2 cm 4m in proportion to object distance DIP 2 ON Testbody 700 mm 300 mm 200 mm testbody CA according to EN 16005 DIN 186...

Отзывы: