background image

2

1

5

6

7

8

4

9

3

1. 

LCD

2. 

radar antenna (narrow field)

3. 

radar antenna (wide field)

4. 

IR-curtain width adjustment

5. 

IR-lenses

DESCRIPTION

6. 

cover

7. 

main connector 

8. 

main adjustment knob

9. 

IR-curtain angle adjustment knob

Opening & safety sensor 

for automatic sliding doors 

User’s Guide for product version 0400 and higher
See product label for serial number

ACCESSORIES

BA: Bracket accessory

CA: Ceiling accessory

CDA: Curved door accessory

(according to EN 16005 and DIN 18650)

RA: Rain accessory

Download the BEA DECODER app 

for a quick overview 

of settings

9 V battery

ENGLISH

Содержание IXIO-DP1

Страница 1: ...nob 9 IR curtain angle adjustment knob Opening safety sensor for automatic sliding doors User s Guide for product version 0400 and higher See product label for serial number ACCESSORIES BA Bracket accessory CA Ceiling accessory CDA Curved door accessory according to EN 16005 and DIN 18650 RA Rain accessory Download the BEA DECODER app for a quick overview of settings 9 V battery ENGLISH ...

Страница 2: ...L FUNCTIONING FACTORY VALUE VS SAVED VALUE NAVIGATING IN MENUS Scroll menu items Push to enter the LCD menu new value is displayed more values are displayed current value is displayed displayed value saved value displayed value factory value Opening impulse Safety 6 6 Enter password if necessary Not during the first minute after power on of the sensor CHANGING A ZIP CODE Password X X X X ZIP code ...

Страница 3: ... size 9 immunity 2 field size 9 immunity 2 field size 9 immunity 2 The size of the detection field varies according to the mounting height of the sensor from 15 to 45 default 30 from 15 to 15 default 0 ENGLISH IXIO DP1 INSTALLATION GUIDE GREEN BROWN YELLOW WHITE PINK GREY POWER SUPPLY POWER SUPPLY OPENING INPUT SAFETY OUTPUT SAFETY INPUT Output status when sensor is operational SENSOR Do not inver...

Страница 4: ...utside door sensor should always be smaller than 20 cm The distance to the door leaf depends therefore on the thickness of the door leaf The size of the detection field varies according to the mounting height and the settings of the sensor The full door width must be covered OR STANDARD standard in and outdoor installations CRITICAL ENVIRONMENT critical installations due to surroundings or weather...

Страница 5: ...se to each other should have a different frequency increased immunities 1 curtain increased immunities redirection motion and presence factory values for radar immunity IR immunity IR number and redirection small large bi uni uni AWAY low 0 5 s 1 s 2 s 3 s 4 s 5 s 6 s 7 s 8 s 9 s uni PRM bi auto uni auto PRM auto PRM for persons with reduced mobility AWAY unidirectional motion away from sensor aut...

Страница 6: ...ened firmly Check position of cable and cover Increase the IR immunity filter to value 3 Select presetting 2 or 3 Select presetting 2 or 3 Increase radar immunity filter Change radar field angle Check if the sensor and door cover is fastened firmly Check position of cable and cover Change radar field size or angle Remove the objects if possible Launch an assisted setup and adjust the IR angle Repl...

Страница 7: ...e for carrying out a risk assessment and installing the sensor and the door system in compliance with applicable national and international regulations and standards on door safety The manufacturer of the sensor cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor Only trained and qualified personnel may install and setup the sensor The warranty is inva...

Страница 8: ... 5 cm typ Number of spots max 24 per curtain Number of curtains 2 Input Pulse polarity positive or negative adjustable Impedance Positive pulse 2 K to ground Negative pulse 470 R to sensor power supply Pulse voltage 6 V to 30 V Pulse duration 4 µs to 500 µs Duty cycle max 50 Output Pulse polarity negative Level Standby Pulse from V to ground Detection V Supply Topology op collector with 4 7 K to 3...