BEA Eagle5 Скачать руководство пользователя страница 1

1/2 

EAGLE 5&6 

USER’S GUIDE

 

 

 

 

 

 
 
 

UNIVERSAL MOTION SENSORS FOR AUTOMATIC DOORS 

 

 

 

 

 

 

JST-connector 

 

Brown 
Green

 

Power supply

 

White

 

Relay (COM)

 

Yellow

 

Relay (NO)

 

 

 

Sensitivity potentiometer 

 

 

 

LED   

- flashes after power-on 

- lights up during detection 

 
 

 

Dip switch 

 

 
Planar antenna  

for wide detection field 

 

Dip switch settings

 

 

 

EAGLE 5 

 

DIP SWITCH 1 

Detection mode 

DIP SWITCH 2 

Relay configuration 

DIP SWITCH 3 

MTF-mode 

DIP SWITCH 4 

Immunity 

 

OFF

 

Bidirectional mode 

Active output 

Unidirectional without MTF 

Normal immunity 

 

ON

 

Unidirectional mode 

Passive output 

Unidirectional with MTF 

Increased immunity 

 

EAGLE 6 

 

DIP SWITCH 1 

Detection mode 

DIP SWITCH 2 

Relay configuration 

DIP SWITCH 3 

MTF-mode 

DIP SWITCH 4 

Immunity 

 

OFF

 

Bidirectional mode 

Active output 

Normal immunity 

 

ON

 

Passive output 

Increased immunity 

 

 

 

 
 

The sensitivity settings determine the size of the sensing field

 

 

 
 

MIN

MAX

MIDDLE

                                    

 

vertical angle: 30°, mounting height: 2.2m

 

 

 

 

 

 

 

The lateral angle of the planar antenna determines the position of the sensing field

 

 

                    

               

    

 

 
 
 

 

 

 

The vertical angle of the planar antenna determines the depth of the sensing field

 

 

                   

15° 30° 45°

30°

45°

15°

        

2

1

0

1

2

1

2

3

1

2

3

15

30

45

   

sensitivity: maximum

 

 
 

1 General 

information 

2 Adjustments 