BEA Eagle One HM Скачать руководство пользователя страница 1

EAGLE ONE HM

1

2

4

3

* Other use of the device outside of the permitted purpose can not be guaranteed by the manufacturer.

TECHNICAL SPECIFICATIONS

DESCRIPTION

ENGLISH

UNIDIRECTIONAL OPENING SENSOR 

FOR HIGH MOUNTING ON AUTOMATIC DOORS*

1. 

main connector

2. 

antenna

3. 

push buttons

4. 

cover

Technology:
Transmitter frequency:  
Transmitter radiated power:
Transmitter power density:
Detection mode:
Min. detection speed:
Supply voltage:
Mains frequency:
Max power consumption:
Output: 
   Max. contact voltage:
   Max. contact current:
   Max. switching power:
Mounting height: 
Degree of protection:
Temperature range:
Dimensions:
Tilt angles:
Material:
Weight:
Cable lenght:
Conformity:

microwave and microprocessor
24.150 GHz
< 20 dBm EIRP
< 5 mW/cm²
motion
5 cm/s
12V to 24V AC ±10%; 12V to 24V DC +30% / -10%
50 to 60 Hz
< 2 W
relay (free of potential change-over contact)
42V AC/DC
1A (resistive)
30W (DC) / 60VA (AC)
from 4 m to 5 m 
IP54
from -20 °C to + 55 °C
120 mm (L) x 80 mm (H) x 50 mm (W)
0° to 90° vertical; -30° to +30° lateral
ABS
215 g
2.5 m
RED 2014/53/EU, RoHS 2 2011/65/EU

Specifications are subject to changes without prior notice.

Measured in specific conditions.

User’s Guide for product version 0600 and higher
See product label for serial number

Th

is u
se

r’s g
uid

e i

s a
n i

nf

or

m

at

ive d
o

cu

m

en

t a

nd 

ca

n n
ot b
e s
ee

n a
s a c

om

m

itm

en

t o
f r

es

ult

.

Содержание Eagle One HM

Страница 1: ...eight Degree of protection Temperature range Dimensions Tilt angles Material Weight Cable lenght Conformity microwave and microprocessor 24 150 GHz 20 dBm EIRP 5 mW cm motion 5 cm s 12V to 24V AC 10 12V to 24V DC 30 10 50 to 60 Hz 2 W relay free of potential change over contact 42V AC DC 1A resistive 30W DC 60VA AC from 4 m to 5 m IP54 from 20 C to 55 C 120 mm L x 80 mm H x 50 mm W 0 to 90 vertica...

Страница 2: ...icated Fix the sensor firmly Avoid proximity to neon lamps or moving objects Do not cover the sensor Avoid vibrations Do not touch electronical parts APPLICATIONS Connect the wires accordingly 1 BROWN POWER SUPPLY 2 GREEN POWER SUPPLY 3 WHITE COM 4 YELLOW NO 5 YELLOW NC Wall mounting above sliding or revolving door Ceiling mounting in front of door sliding revolving or swing doors Mounting on door...

Страница 3: ...ntact bi uni uni PRM FACTORY VALUES low normal Adjust the lateral antenna angle Adjust the vertical antenna angle OR RESETTING TO FACTORY VALUES ANGLE uni AWAY PRM AWAY uni PRM one way detection also of people with reduced mobility uni AWAY one way detection away from sensor HOLD OPEN TIME MOUNTING HEIGHT DOOR CONTROL 0 5 s 1 s 2 s 3 s 4 s 5 s 6 s 7 s 8 s 9 s auto open closed open the sensor detec...

Страница 4: ...detection mode is unidirectional Increase the antenna angle Increase the immunity filter Reduce the field size Change the antenna angle Decrease the field size Increase the immunity filter Enter the right access code If you forgot the code cut and restore the power supply to access the sensor without access code Change or delete the access code Check and change the batteries if necessary Point the...

Отзывы: