BEA Eagle 10 Скачать руководство пользователя страница 1

75.5185.04  20070727                                                                                              

 

Page 1 of 8 

 

 

EAGLE 

USER GUIDE 

 

 

 

 
 
 

 
 
 

          

 

 

 
 

NOTE: For mounting heights between 10’ and 16’, use BEA model 10EAGLEHM (high mount). 

 

 

 

DESCRIPTION 

SPECIFICATION 

Frequency:    

24.125 GHz 

Supply voltage: 

12 to 24 V AC: 

±

 10%:  

12 to 24 V DC: -10% / +30%:  

Mounting height: 

Normal: 7’;   Maximum: 10’-0” 

Tilt angle: 

0

°

 to 90

°

 vertical 

-15

°

 to +15

°

 lateral 

Detection area:   
Wide 
Narrow 

 
13ft (W) x 6.5ft (D) 
6.5ft (W) x 8.2ft (D) (supplied as optional) 

Minimum detection speed: 

2 in/sec.  (measured in axis) 

Power consumption: 

< 2 W 

Standard output relay: 
Max contact voltage 
Max contact current 
Max switching power 

 
60 VDC / 125 VAC 
1 A (resistive) 
30W (DC) / 60VA (AC) 

Hold time: 

0.5 sec. to 9 sec. (adjustable) 

Temperature range: 

-4°F to 131°F 

Dimensions: 4.75in 

(W) 

3.15in (H) x 2.0in (D) 

Weight: 

0.5lbs 

Material: ABS 
Housing color: 

Black. Can be painted with non-metallic paint 

Cable length: 

6ft 

 
 
 
 

1 Description 

2 Technical 

Specifications 

Terminal 
Block

 

Narrow Antenna Storage

 

Manual Set-Up Buttons

 

Wire Passage Hole

 

Planar Antenna

 

Lateral and Angle 
Adj. For Antenna

 

Opening Tab

 

Wire Opening Knockout 
(inside the cover)

 

Front Cover

 

LED

 

Содержание Eagle 10

Страница 1: ...in sec measured in axis Power consumption 2 W Standard output relay Max contact voltage Max contact current Max switching power 60 VDC 125 VAC 1 A resistive 30W DC 60VA AC Hold time 0 5 sec to 9 sec a...

Страница 2: ...e can build up on the human body and then discharge when you touch a board A discharge can be produced when walking across a carpet and touching a board for example Before handling any board make sure...

Страница 3: ...picture Drill as instructed Pass the cable where indicated 4 Electrical Installation Terminal Connection 1 Red 12 to 24 VAC DC 2 Black 12 to 24 VAC DC 3 White Relay Common 4 Green Relay N O 5 Relay N...

Страница 4: ...SENSING FIELDS ACCORDING TO THE VERTICAL TILT ANGLE OF THE ANTENNA The sensing fields on the right correspond to the following adjustments wide sensing field antenna vertical angle of the antenna 0 20...

Страница 5: ...E THE DIMENSIONS WIDTH DEPTH OF THE SENSING FIELD DEPEND ON THE MOUNTING HEIGHT The sensing fields on the right correspond to the following adjustments Wide sensing field antenna Vertical angle of th...

Страница 6: ...following the last detection of motion toward the door At the end of the 2 second time frame if the Eagle does not detect any further motion it switches back to the unidirectional mode Unlock Inquire...

Страница 7: ...one unit Immunity Immunity helps to reduce the chance of unwanted detections due to environmental disturbances 1 Reduced 2 Normal 3 Increased 4 through 9 enhanced immunity for highly reflective enviro...

Страница 8: ...munity In airlock vestibules the sensor sees the movement of the door leaves despite of an increased immunity Make sure the antenna for the narrow sensing field is used In metallic environments the se...

Отзывы: