PRODUCT 
DESCRIPTION

 

TECHNICAL 
SPECIFICATIONS

 

COMPONENT ID

 

SAFETY  
PRECAUTIONS 

 

 

 

 

 
 
 
 

The Crystal Active Infrared presence detector (PN: 10CRYSTALPRE) is ideal for threshold safety and sidelite protection for 

sliding doors, as well as threshold protection on the approach side of a swinging or bi-folding door. It is universally 
compatible with any automatic door control, and is quick and easy to install.  The Crystal technology utilizes  multiplexing, 
which assures that it is constantly scanning the background looking for any changes.  Therefore, if the change in 
background remains constant for a set time (adjustable 1 minute or 10 minutes), the sensor learns it and allows your door 
to return to normal operation.  

 

 

NOTE

:  

The Crystal should not be used as a motion detector.  The Crystal’s detection pattern does not meet 

the minimum motion pattern requirements as stated by ANSI A156.10.

 

 

 

 

 

 
 

 
 
 

                                           

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

• 

Shut off all power going to the header before attempting any wiring procedures. 

• 

Maintain a clean & safe environment when working in public areas. 

• 

Constantly be aware of pedestrian traffic around the door area. 

• 

Always stop pedestrian traffic through the doorway when performing testing that may result in unexpected reactions by 

the door. 

• 

Always check placement of all wiring and components before powering up to insure that moving door parts will not 

catch any wires and cause damage to equipment. 

• 

Ensure compliance with all applicable safety standards (i.e. ANSI A156.10) upon completion of installation. 

 

 

TECHNICAL SPECIFICATIONS 

Installation Height: 

7’ to 10’ 

Detection Zone: 

Wide pattern:  6’  
Narrow pattern:  3’ 
Depth:  4” 

Mounting Angle: 

from 3° to 21° 

Power Supply: 

12 to 30 V DC ± 10% 
12 to 24 V AC ± 10% 

Consumption: 

< 1 W (VA) 

Output - Contact Ratings: 
Max. voltage 
Max. current 
Max. switching power 

Dry Contacts 
60 V DC / 125 V AC 
1 A (resistive) 
30 W (DC) / 60 VA (AC) 

Frequency: 

50 to 60 Hz 

Response Time: 

< 50ms 

Relay hold time:  

1.5 seconds (fixed) 

Auto Learn Time 

1 or 10 minutes 

Temperature range: 

-30° to +131° F 

Dimensions: 

10” L x 2” H x 1.5” D 

Weight: 7 

oz. 

Material:  

Black ABS and polycarbonate 

Length of Cable: 

6’ 

USERS GUIDE

  

CRYSTAL

 

PRESENCE SENSOR 

 

Cover

 

Supply

 

Cable

 

Emitting

 

lens

 

Receiving 
lens

 

LED

 

DIP

 

Switches

 

Connector

 

Learn time

 

Angle 

 

adjustment

 

OBSOLETE

Содержание CRYSTAL

Страница 1: ...ronment when working in public areas Constantly be aware of pedestrian traffic around the door area Always stop pedestrian traffic through the doorway when performing testing that may result in unexpected reactions by the door Always check placement of all wiring and components before powering up to insure that moving door parts will not catch any wires and cause damage to equipment Ensure complia...

Страница 2: ...r and the door control according to the following color code BEA Inc recommends the use of an isolated transformer to power the sensor 2 Where the Crystal is wired to on the door control depends on the specific application For example a If the Crystal is installed to provide additional threshold protection it would normally be connected to the ACTIVATE and COMMON terminals of the door control see ...

Страница 3: ...switch must be wired in parallel with the Crystal in order to allow activation by the motion sensor when the door is other than fully closed and the Crystal is in detection If the Crystal is in detection while the door is fully closed the door will not open When the door is open only the motion sensor when in detection may keep the door open See schematic below Door Control Activation Device Activ...

Страница 4: ...tically learn any permanent changes in its field of detection The time may be set for 1 minute or 10 minutes and begins counting down once a change in the detection zone occurs If the object is removed from the zone before the time delay has expired the Crystal will not save it as part of its memory During the auto learn time the Crystal will stay locked on and once the Crystal has learned the obj...

Страница 5: ...will also decrease as the mounting height of the Crystal is decreased ALWAYS be sure to walk test the door upon completion of all sensor adjustments to insure compliance with applicable safety standards i e ANSI A156 10 3 15 7 11 19 4 4 12 18 26 34 8 2 2 When the installation is complete re install cover Make sure the cable is routed around the plastic post to help prevent water from entering the ...

Страница 6: ...after hours call East Coast 1 866 836 1863 or 1 800 407 4545 Mid West 1 888 308 8843 West Coast 1 888 419 2564 DO NOT leave any problem unresolved If you must wait for the following workday to call B E A leave the door inoperable until satisfactory repairs can be made NEVER sacrifice the safe operation of the automatic door or gate for an incomplete solution Web www beasensors com PN 10URC Univers...

Отзывы: