background image

1 PWR
2 PWR
3 COM
4 NO
5 NC
6 IN -
7 IN +

RED
BLACK
WHITE
GREEEN

BROWN
BLUE

10 PIN

PCB

BODYGUARD III

QUICK SETUP GUIDE

PRESENCE SENSOR FOR PEDESTRIAN DOORS

The Bodyguard III Quick Setup Guide is for the installation and setup of the Bodyguard III.  This document is provided for experienced installers, 

service personnel & AAADM Certified Inspectors that are familiar with the Bodyguard III.  For those who are not completely familiar with the 

installation and setup of the Bodyguard III, BEA recommends following the detailed installation and setup instructions found in the Bodyguard III 

User’s Guide (75.5134).  Bodyguard performance shall be adjusted and in compliance with all applicable current safety standards (ANSI A156.10).

75.5362.01   20090210 

 

 

 

 

 

 

 

 

 

 

Page 1 of 2

1   Description

2   Installation

1.  The Bodyguard shall be mounted near flush with the bottom of the automatic door header on the swing side.  This is absolutely necessary to allow 

the Bodyguard detection pattern to reach back through the threshold area when the door is in the open position.  If any portion of the door face or 

related hardware on the swing side project beyond the Bodyguard face, a Bodymount must be installed in conjunction with the Bodyguard.

2.  The Bodyguard should be mounted at a height range of 6’ 6” to 8’ (Max. of 9’).

3.  The Bodyguard should be center mounted up above on the header and flush with the bottom of the automatic door header.  This is absolutely 

necessary to allow the detection pattern to reach back through the threshold area with the Bodyguard is in the open door position.

SINGLE DOOR APPLICATIONS

 - The Bodyguard should be mounted overhead at the center of the door opening.  However, if this is not possible, the 

unit may be installed off-center.  In such cases, pattern location will have to be altered for proper placement of the 

field of detection.  Try to avoid mounting locations that may pose potential problems such as directly over a door arm.

DOUBLE-EGRESS APPLICATIONS

 - One Bodyguard shall be mounted overhead on the header over each swing-path.  There should be at least 40” 

of separation between the 2 Bodyguards when measured between the centerline of each sensor.  Most double 

egress applications are knowing act.  Ensure compliance with current ANSI 156.10-2005 Section 9.2.  Most 

double egress installations will require IR frequency and/or open door pattern depth adjustments.  Change IR 

frequency of one Bodyguard to 3 and the other to 4 (See Tech Bulletin #32 or Bodyguard User Guide 75.5134 

for more explicit information regarding double egress applications with respect to location and setting up the 

Bodyguard.  

3   Wiring

Use the cable that is provided for use with the 

10-pin connector as shown or wire the 7-pin 

terminal block.  If wiring the Bodyguard to a 

BEA module (i.e. LO LINX or a version of the 

LO-21), refer to the wiring diagrams for the 

respective module.   For ease of installation, 

wire the terminal before attaching it to the 

Bodyguard.

4   Mechanical Adjustment

5   Setup

1.  Upon completion of mechanical and electrical installation, apply 12 to 24 VAC/VDC +/- 10% to the Bodyguard with the door in the closed position.  

The Bodyguard will flash a green LED at a rate of 2 Hz, then it will expire upon a successful set-up in the door closed position.

NOTE

:  If applying the Bodyguard to a door control that requires a learn cycle upon powering, it is recommended to allow the doors to complete a 

learn cycle before applying power to the Bodyguard.

2.  Activate the door to the full open position.  When using BEA’s lockout relay, the Bodyguard will once again flash the green LED and will 

execute a door-open set-up.  Upon completion of the set-up for the door-open position, the doors will begin closing.  Normal operation should 

resume thereafter.  Proceed with fine-tuning to insure compliance with all current applicable safety standards (i.e. ANSI A 156.10).  If set-up is 

unsuccessful, refer to the Troubleshooting Guide at the end of the Bodyguard User’s Guide (75.5134) and also to the guide located at the end of 
the respective lockout User’s Guide.

HELPFUL HINT

:  After set-up and to confirm the correct motor polarity to the lockout, the correct data and data polarity and to ensure the lockout is 

communicating properly to the Bodyguard.  Activate the door open and perform a door open set-up with the remote by pressing 

Unlock, Magic Wand, #2.  If the Bodyguard flashes green continue with final tune in.  If not, refer to Bodyguard User Guide 

(75.5134).  The most likely cause is the motor lead polarity is reversed at the lockout or data polarity is reversed at Bodyguard.

POS

CONNECTION (7-Pin)

WIRE COLOR 

(10-Pin Cable)

1

12 to 24 VAC/VDC +/- 10%

Red

2 12 to 24 VAC/VDC +/- 10%

Black

3

COM

White

4

NO

Green

5

NC

6

Data -

Brown

7

Data +

Blue

5° Default Angle

NOTE

: Never short the data wires 

when power is applied as this 

will destroy the lockout.

1.  Aside from placement on the header, the only mechanical adjustment that may be made to the sensor is the angle 

adjustment.  The Bodyguard is factory pre-set to the +5° position, but may be reduced to a 0° position or increased to 

a 10° position.  The greater the angle, the farther from the door the pattern will be.  The 0° angle should only be used 

when the Bodyguard is mounted to a Bodymount block or to a soffit above the door that extends out from the face of the 

swing side of the door (in this case, the 0° setting would improve the location of the detection field across the threshold 

area of the doorway).  It is recommended that for most applications, the unit be powered and walk tested at the pre-set 

5° angle.  After walk testing, if the detection field needs to be changed, then proceed with changes as explained next.

2.  To change the angle setting the end caps, lenses, center eye shield and terminal block if it has been wired must be 

removed.  Once removed, release the white clips and rotate outward to remove the PCB.  Once the PCB is completely 

removed from the housing, the angle position may be changed.  There are two clips per Bodyguard and the angle must 

match for each clip on the PCB.