background image

 

1

User Manual for C1100M8-12GX

 

(

PCB

C11M8-Z01B

)

 

 

 

Before Operation: 

Before issuing MF1 keys, please choose Free-use Key or Assigned-use Key operating mode 
and Manual or Automatic locking mode first, that depends on 2 switches’ position as below: 

Assign-use Key Mode: S1 = S 

(under this mode, the guest key can be used for only 1 specified locker) 

Free-use Key Mode:    S1 = D 

(under this mode, the guest key can be used for any unoccupied locker)

 

Manual Locking Mode: S2 = M 
Automatic Locking Mode: S2 = A; 

 

Set New Keys: 

A. 

Set Owner Key

 (1 Owner key for 1 lock) 

After loading the batteries into battery holder, touch the first MF1 key on the receptor, the key 
set as owner key. 

Change Owner Key

:  

Press the “Reset” button and hold for 1 second, blue light will on, after 3 beeps sound, touch 
a MF1 key on the receptor, the key set as new owner key (all the existing keys will be 
deleted). 
Note: Only one owner key is allowed for a lock, the owner key is used to issue or delete 
master key, BUT not used to unlock. 
 
B. 

Set Master Key

(1 Master Key for 1 lock) 

Touch owner key on the receptor, after a "beep" sound, blue light slowly blink, touch a MF1 
key, after a "beep" sound, blue light will off, and the key set as master key. 
Note: Only one master key is allowed for a lock, the master key is used to unlock and 
program service key and guest key (based on Assigned-use Key mode) 
 