background image

 

 
                                                      
 

I. Basic Description 

 
The PSW-100 Pressure Sensor is designed to be a direct plug in accessory to all BDI 
DPS-100D and ERI PWR-100D True RMS Power Sensors. The PSW-100 Accepts 5 
VDC and Ground and outputs a D.C. voltage in the range of 0.5-4.5 VDC linearly 
corresponding to 0-15 PSI.  
 

II. Installation Instructions 
 
 

The PSW-100 is supplied with a three position push on connector. 

 

1.  Install the sensor by applying a small amount of Teflon tape to the threads of the 

sensor.  

2.  Screw the sensor into the gas receptacle on the transmission line. Do not 

overtighten the sensor as typically it will be installed into a brass fitting and can 
the brass threads can easily be stripped if overtightened. If Teflon tape has been 
used it should only be necessary to snug the fitting in place.  

3.  Using soapy water in a spray bottle spray the fitting to check for leaks. 
4.  Plug the three position connector into the socket marked “PRES” on top of the 

DPS-100D or PWR-100D sensor.  

5.  Check the pressure indication on the face of the DPS-100D or PWR-100D 

sensor or log into the web page to view all parameters.  

 
Note: 
 
It is possible to use the PSW-100 Pressure Sensor with a remote control without the 
use of a BDI DPS-100D or ERI PWR-100D sensor. 

Please follow the instructions 

below carefully as an error in wiring will cause damage to the sensor and will void 
the warranty.  
 

1.  Remove the three position connector by pressing the orange release button 

under each hole. 

 

2.  Connect the BLACK wire to common-ground

 

3.  Connect the WHITE wire to the metering input of the remote control

 

4.  Connect the Red wire to a +5 VDC source. The ground for the +5 VDC source 

must be common to where the BLACK common-ground wire is connected on the 
remote control

 

5.  Follow your remote control manufacturers instructions for providing a linear read 

out of the PSW-100 sensor. The sensor will indicate 0 – 15 PSI for a  0.5-4.5 
VDC output from the sensor. See Fig. 2 Transducer Specifications for complete 
detail.

 

 

 

 