BD Sensors EP 500 Скачать руководство пользователя страница 1

Operating Manual 

Pressure Transmitter for Shipbuilding and Offshore  
Applications 

EP 500 

 

Headquarters 

BD SENSORS GmbH 
BD-Sensors-Str. 1 
D - 95199 Thierstein 
Germany 
Tel.: +49 (0) 9235-9811-0 
Fax: +49 (0) 9235-9811-
11 

Eastern Europe 

BD SENSORS s.r.o. 
Hradištská 817 
CZ - 687 08 Buchlovice 
Czech Republic 
Tel.: +42 (0) 572-4110 11 
Fax: +42 (0) 572-4114 97 

Russia  

BD SENSORS RUS 
39a, Varshavskoe shosse 
RU - Moscow 117105 
 
Russia 
Tel.: +7 (0) 95-380 1683 
Fax: +7 (0) 95-380 1681 

China  

BD SENSORS China Co, Ltd. 
Room B, 2nd Floor, Building 10, 
No. 1188 Lianhang Rd. 
201112 Shanghai,  
China 
Tel.: +86 (0) 21-51600 190 
Fax: +86 (0) 21-33600 613 

further agencies in: 

EUROPE

 

  Belgium 

  Denmark 

  France 

  Greece 

  Italy 

  Lithuania 

  Luxemburg 

  Netherlands 

  Norway 

 

  Poland 

  Romania 

  Sweden 

  Switzerland 

  Slovakia 

  Spain 

  Turkey 

  UK 

  Ukraine 

ASIA 

  Iran 

  Israel 

  Kazakhstan 

  Taiwan 

  Thailand 

AUSTRALIA 

The  addresses  of  our  distribution  partners  are  listed  on  our 
homepage 

www.bdsensors.com

. It is possible to download 

data  sheets,  operating  manuals,  ordering  codes  and  certifi-
cates, as well. 

1. General information 

1.1 Information on the operating manual 

This  operating  manual  contains  important  information  on 
proper  usage  of  the  device.  Read  this  operating  manual 
carefully  before  installing  and  starting  up  the  pressure 
measuring device. 

Adhere to the safety  notes and  operating instructions which 
are  given  in  the  operating  manual.  Additionally  applicable 
regulations  regarding  occupational  safety,  accident  preven-
tion  as  well  as  national  installation  standards  and  engineer-
ing rules must be complied with! 

This  operating  manual  is  part  of  the  device,  must  be  kept 
nearest its location, always accessible to all employees. 

This  operating  manual  is  copyrighted.  The  contents  of  this 
operating manual reflect the version available at the time of 
printing. It has been issued to our best knowledge. However, 
errors  may  have  occurred.  BD  SENSORS  is  not  liable  for 
any incorrect statements and their effects. 

– Technical modifications reserved – 

1.2 Symbols used 

 

DANGER!  –  dangerous  situation,  which  may  result  in 
death or serious injuries 

 

WARNING!  –  potentially  dangerous  situation,  which 
may result in death or serious injuries 

 

CAUTION! – potentially dangerous situation, which may 
result in minor injuries 

!

 

CAUTION! – potentially dangerous situation, which may 
result in physical damage  

 

NOTE  –  tips  and  information  to  ensure  a  failure-free 
operation 

1.3 Target group 

 

WARNING! To avoid operator hazards and damages of 
the device, the following instructions have to be worked 
out by qualified technical personnel. 

1.4 Limitation of liability 

By  non-observance  of  the  operating  manual,  inappropriate 
use,  modification  or  damage,  no  liability  is  assumed  and 
warranty claims will be excluded. 

The  conformity  of  the  produced  end  device  has  to  be  en-
sured by the responsible design engineer or developer. 

1.5 Intended use 

-  The pressure transmitter EP 500 has been designed for 

hard  conditions  especially  in  shipbuilding  and  offshore 
applications. The EP 500 is intended, depending on the 
ordered pressure range, for the pressure  measurement 
of  gauge  or  absolute  pressure.  A

 

typical  application  is 

e.g. level measurement via air bubbling. The EP 500 ful-
fil  the  requirements  of  Germanischer  Lloyd  (GL)  as 
standard.  The  certificate  is  available  for  download  on 
our 

homepage: 

http://www.bdsensors.com/proucts/ 

download/certificates 

-  It is the operator's responsibility to check and verify the 

suitability  of  the  device  for  the  intended  application.  If 
any doubts remain, please contact our sales department 
in  order  to  ensure  proper  usage.  BD  SENSORS  is  not 
liable for any incorrect selections and their effects! 

-  Permissible media are gases or liquids, which are com-

patible with the media, wetted parts of the device. 

-  The  technical  data  listed  in  the  current  data  sheet  are 

engaging and must be complied with. If the data sheet is 
not  available,  please  order  or  download  it  from  our 
homepage:  http://www.bdsensors.com/products/down-
load/datasheets 

 

WARNING!

 

Danger through improper usage!  

1.6 Package contents 

Please verify that all listed parts are undamaged included in 
the  delivery  and  check  for  consistency  specified  in  your 
order: 

-  pressure transmitter EP 500 

-  mounting instructions 

2. Product identification 

The  device  can  be  identified  by  its  manufacturing  label.  It 
provides  the  most  important  data.  By  the  ordering  code  the 
product can be clearly identified.

 

Fig. 1 manufacturing label 

!

 

The manufacturing label must not be removed from the 
device! 

3. Mechanical installation 

3.1 Mounting and safety instructions 

 

WARNING!  Install  the  device  only  when  depressurized 
and currentless! 

 

WARNING!  This  device  may  only  be  installed  by 
qualified  technical  personnel  who  has  read  and  under-
stood the operating manual! 

!

 

Handle 

this 

high-sensitive 

electronic 

precision 

measuring  device  with  care,  both  in  packed  and 
unpacked condition! 

!

 

There are no modifications/changes to be made on the 
device.  

!

 

Do not throw the package/device! 

!

 

To  avoid  damaging  the  diaphragm,  remove  packaging 
and  protective  cap  directly  before  starting  assembly. 
The delivered protective cap has to be stored! 

!

 

Place  the  protective  cap  on  the  pressure  port  again 
immediately after disassembling. 

!

 

Handle  the  unprotected  diaphragm  very  carefully  - it is 
very sensitive and may be easily damaged. 

!

 

Do  not  use  any  force  when  installing  the  device  to 
prevent damage of the device and the plant! 

!

 

For  the  installation  following  points  have  to  be  ob-
served: 

-  By factory, the device has an ingress protection of 

IP  00.  Therefore  the  mounting  /  installation  has  to 
be performed carefully. Additionally the device has 
to  be  protected  from  the  environmental  effects  by 
the installation in a ventilated housing, with a much 
higher ingress protection than the device. Check, if 
the  desired  ingress  protection  is  sufficiently  for 
your application. (recommendation: IP 65 at least) 

-  Install the device in such a way that it is protected 

from direct solar irradiation. Direct solar irradiation 
can  lead  to  the  permissible  operating  temperature 
being overstepped in the worst case. Through this, 
the  operability  of  the  device  can  be  affected  or 
damaged. If the internal pressure increases due to 
solar  irradiation,  temporary  measurement  errors 
may occur. 

-  Install  the  device  in  such  a  way,  that  the  gauge 

reference,  which  is  necessary  for  measuring,  is 
protected from dirt and moisture.  

-  Take  note  that  no  assembly  stress  occurs  at  the 

pressure  port,  since  this  may  cause  a  shifting  of 
the characteristic curve.  

 

Provide  a  cooling  line  when  using  the  device  in  steam 
piping. 

 

If  there  is  any  danger  of  damage  by  lightning  or 
overpressure  when  the  device  is  installed  outdoor,  we 
suggest putting a sufficiently dimensioned overpressure 
protection between the supply or switch cabinet and the 
device. 

3.2 General installation steps 

-  Carefully  remove  the  pressure  measuring  device  from 

the package and dispose of the package properly. 

-  Go ahead as detailed in the specific instructions below.  

3.3 Installation steps for tube nozzle 

-  Slip your flexible tubes (

4 mm) onto the tube  nozzles 

as far as possible. 

3.4 Installation steps for G 1/4" acc. to EN 837 

-  Use  a  suitable  seal,  corresponding  to  the  medium  and 

the pressure input (e. g. a cooper gasket). 

-  Ensure  that  the  sealing  surface  of  the  taking  part  is 

perfectly smooth and clean. 

-  Screw  the  device  into  the  corresponding  thread  by 

hand. 

-  Tighten it with a wrench (approx. 20 Nm). 

4. Electrical installation 

 

WARNING!

 

Install  the  device  in  currentless  environ-

ments only! 

Establish the electrical connection of the device according to 
the  technical  data  shown  on  the  manufacturing  label,  the 
following table and the wiring diagram. 

Pin configuration: 

Electrical 
connections 

Terminal 

clamps

 

M12x1 (8-polig), 

metal

 

Supply 

+

Supply - 

Tx 

Rx 

GND 

NC 









Shield 

Figure 

 

 
 
 
 
 

 

 

Wiring diagram: 

 

For  the  electrical  connection  a  shielded  and  twisted 
multicore cable has to be used. 

 

ordering code 

connector pinout 

type designation 

supply 

nominal 

pressure 

range 

signal 

serial 

number 

 

supply – 

 

V

S

 

 

 

www.bdsensors.com 

EN 

Option EP 500 - 500 