Operating Manual

 

 

Digital Gauge DM 10, DM 17 

READ THOROUGHLY BE FORE USING THE DEVICE 

KEEP FOR FUTURE REFERENCE 

ID: BA_DM1X_E | Version: 03.2022.0 

1. General and safety-related information on  
   this operating manual 

This operating manual enables safe and proper handling of the 
product, and forms part of the device. It should be kept in close 
proximity to the place of use, accessible for staff members at 
any time. 

All persons entrusted with the mounting, installation, putting into 
service, operation, maintenance, removal from service, and 
disposal of the device must have read and understood the 
operating manual and in particular the safety-related information.  

Complementary to this operating manual the current data 
sheet has to be adhered to. 

Download the data sheet by accessing 

www.bdsensors.de 

or 

request it: [email protected] | phone: +49 (0) 92 35 / 98 11 0  

In addition, the applicable accident prevention regulations, 
safety requirements, and country-specific installation standards 
as well as the accepted engineering standards must be 
observed. 

1.1 Symbols Used 

 

Warning word

 

-  Type and source of danger 
-  Measures to avoid the danger 

 

Warning word

 

Meaning

 

 

DANGER

 

-  Imminent danger! 
-  Non-compliance 

will result in

 

death or serious injury. 

WARNING

 

-  Possible danger! 
-  Non-compliance 

may result in

 

death or serious injury. 

 

CAUTION

 

-  Hazardous situation! 
-  Non-compliance 

may result in

 

minor or moderate injury. 

NOTE

 - draws attention to a possibly hazardous situation that 

may result in property damage in case of non-compliance.  

 

Precondition of an action 

1.2 Staff qualification 

Qualified persons

 are persons that are familiar with the 

mounting, installation, putting into service, operation, 
maintenance, removal from service, and disposal of the product 
and have the appropriate qualification for their activity.  

This includes persons that meet at least one of the following 
three requirements: 

They know the safety concepts of metrology and 
automation technology and are familiar therewith as 
project staff. 

They are operating staff of the measuring and 
automation systems and have been instructed in the 
handling of the systems. They are familiar with the 
operation of the devices and technologies described in 
this documentation. 

They are operating staff of the measuring and 
automation systems and have been instructed in the 
handling of the systems. They are familiar with the 
operation of the devices and technologies described in 
this documentation. 

All work with this product must be carried out by qualified 
persons! 

1.3 Intended use 

The battery powered digital pressure gauge DM 1X has been 
designed for applications in hydraulics and pneumatics as well 
as for mechanical engineering. It can be easily and quickly 
installed in situ. 

The user must check whether the device is suited for the 
selected use. In case of doubt, please contact our sales 
department ([email protected] | Phone: +49 (0) 9235 9811 0). 
BD|SENSORS assumes no liability for any wrong selection and 
the consequences thereof! 

Permissible media are gases or liquids, which are compatible 
with the media wetted parts described in the data sheet. In 
addition, it has to be ensured, that this medium is compatible 
with the media wetted parts. 

1.4 Limitation of liability and warranty 

Failure to observe the instructions or technical regulations, 
improper use and use not as intended, and alteration of or 
damage to the device will result in the forfeiture of warranty and 
liability claims. 

1.5 Incorrect use 

 

WARNING 

Danger through incorrect use 

-  Only use the device in permissible 

media and in accordance with its 
intended use.  

-  Do not use the device as a ladder or 

climbing aid. 

-  The device must not be altered or 

modified in any way. 

-  BD|SENSORS is not liable for damage 

caused by improper or incorrect use.

 

1.6 Safe handling 

NOTE -

 

Do not use any force when installing the device to 

prevent damage of the device and the plant!

 

NOTE

 -

 Treat the device with care both in the packed and 

unpacked condition! 

NOTE

 - 

Do not throw or drop the device! 

NOTE

 - 

Excessive dust accumulation and complete coverage 

with dust must be prevented! 

NOTE

 - 

The device is state-of-the-art and is operationally 

reliable. Residual hazards may originate from the device if it is 
used or operated improperly. 

1.7 Scope of delivery 

Check that all parts listed in the scope of delivery are included 
free of damage, and have been delivered according to your 
purchase order: 

-  digital gauge  

-  this operating manual 

1.8 UL approval (for devices with UL marking) 

The UL approval was affected by applying the US standards, 
which also conform to the applicable Canadian standards on 
safety.  

Observe the following points so that the device meets the 
requirements of the UL approval: 

-  only indoor use  
-  maximum operating voltage: see technical data 
-  use only batteries with UL certification 

2. Product identification 

The device can be identified by its manufacturing label. It 
provides the most important data. By the ordering code the 
product can be clearly identified.

 

 

 

Fig. 1 Example of manufacturing label

 

NOTE

 - 

The manufacturing label must not be removed!

 

3. Mounting 

3.1 Mounting and safety instructions 

 

DANGER 

Danger of death from airborne parts, 
leaking fluid, electric shock  

Always mount the device in a 
depressurized condition! 

 

WARNING

 

Danger of death from improper 
installation 

This device may only be installed by 
qualified technical personnel who has 
read and understood the operating 
manual!

 

Do not use the display to tighten or 
solve to the mechanical connection!

 

NOTE 

-

 Handle this electronic precision measuring device 

carefully in packed as well as in unpacked condition! 

NOTE

 -

 Handle the unprotected diaphragm very carefully - it is 

very sensitive and may be easily damaged. 

NOTE

 - 

The device may not be thrown! 

NOTE

 -

 To avoid damaging the diaphragm, remove packaging 

and protective cap only directly before starting up the device. A 
delivered protective cap must be stored! 

NOTE

 -

 Place the protective cap on the pressure port again 

immediately after disassembling. 

NOTE

 - 

Never use the display as a mounting / dismounting 

aid, otherwise the device or the plug-in connections will be 
irreparably damaged. For mounting or dismounting the device, 
only use the hexagon on the pressure port. 

NOTE

 -

 Take note that no inadmissibly high mechanical 

stresses occur at the pressure port as a result of the installation, 
since this may cause a shifting of the characteristic curve or to 
the demage. 

NOTE

 - The permissible tightening torque depends on the 

conditions on site (material and geometry of the mounting point). 
The specified tightening torques for the device must not be 
exceeded! 

NOTE

 -

 In hydraulic systems, position the device in such a 

way that the pressure port points upward (venting). 

NOTE

 -

 Provide a cooling line when using the device in steam 

lines. 

NOTES - 

for mounting outdoors or in a moist  

 

environment:

  

-  Please note that your application does not show a dew point, 

which causes condensation and can damage the device. 
There are specially protected pressure measuring devices for 
these operating conditions. Please contact us in such case. 

-  Select the mounting position such that splashed and 

condensed water can drain off. Stationary liquid on sealing 
surfaces must be excluded! 

-  Mount the device such that it is protected from direct solar 

radiation. In the most unfavourable case, direct solar radiation 
leads to the exceeding of the permissible operating 
temperature. This must be excluded if the device is used in 
any explosion-hazardous area! 

-  A device with gauge reference in the housing (small hole next 

to the electrical connection) must be mounted such that the 
gauge reference is protected against dirt and humidity. If the 
transducer is exposed to liquid admission, the gauge 
reference will be blocked, and the equalization of air pressure 
will be prevented. In this condition, a precise measurement is 
impossible and damage to the transducer may occur.  

3.2 Conditions for oxygen applications 

 

DANGER 

Danger of death from explosion 

when used improperly 

Make sure that your device was ordered for oxygen applications 
and delivered accordingly. (see manufacturing label - ordering 
code ends with the numbers "007") 

Unpack the device directly prior to the installation.  

Skin contact during unpacking and installation must be avoided 
to prevent fatty residues remaining on the device.  
Wear safety gloves! 

The entire system must meet the requirements of BAM  
(DIN 19247)! 

For oxygen applications > 25 bar, devices without seals are 
recommended. 

Device with o-rings of FKM (Vi 567):  
permissible maximum values: 25 bar / 150° C (BAM approval) 

3.3 Mounting steps for connections according  
 

to DIN 3852 

NOTE 

- Do not use any additional sealing material such as 

yarn, hemp, or Teflon tape! 

 

The O-ring is undamaged and seated in the designated 
groove. 

 

The sealing face of the mating component has a flawless 
surface. (R

3.2)

 

Screw the device into the mating thread by hand. 

Devices equipped with a knurled ring:  
only tighten by hand 

Devices with a wrench flat must be tightened using a 
suitable open-end wrench. Permissible tightening torques 
for digital gauge: 

  

  G1/4": approx. 5 Nm 
  G1/2": approx. 10 Nm 

3.4 Mounting steps for connections according  
 

to EN 837 

 

A suitable seal for the measured fluid and the pressure to 
be measured is available. (e.g. a copper seal) 

 

The sealing face of the mating component has a flawless 
surface. (R

Z

 6.3) 

Screw the device into the mating thread by hand. 

Then tighten it using an open-end wrench.  
Permissible tightening torques for digital gauge:  
  G1/4": approx. 20 Nm 
  G1/2": approx. 50 Nm 

3.5 Mounting steps for NPT connections 

 

Suitable fluid-compatible sealing material, e.g. PTFE tape, is 
available.  

Screw the device into the mating thread by hand 

Then tighten it using an open-end wrench.  
Permissible tightening torques for digital gauge:  
  1/4" NPT: approx. 30 Nm 
  1/2" NPT: approx. 70 Nm 

3.6 Mounting steps for 7/16"-20 UNF (DM 17) 

NOTE 

- Do not use any additional sealing material such as 

yarn, hemp, or Teflon tape! 

Screw the device into the corresponding thread by hand. 

Tighten it with a wrench. Permissible tightening torques for 
digital gauge: 
  approx. 20 Nm 

3.7 Positioning of the display module 

The display module of the pressure gauge is rotatable so that 
clear readability is guaranteed even on unusual installation 
positions.

 

Fig. 2 Rotatability 

4. Supply / changing the battery 

The  digital  pressure  gauge  is  supplied  by  a  3  V  lithium-battery 
(type  CR  2450).  Stored  values  /  parameters  are  also  kept  after 
changing the battery. 

As soon as in the display the announcement of "battery" is shown, 
a  battery  change  is  necessary  This  has  only  to  be  done  in 
switched-off condition. 

The battery case is located in the removable display of the 
digital pressure gauge DM 10 / DM 17. 

To change the battery go ahead as follows: 

Remove the cap and change the battery. 

Make sure that the wires are not damaged when 
changing the battery. Prevent twisting as well as tensile 
stress. 

Cap and the housing are sealed by an o-ring 55x1.5. 
Check the sealing surfaces - these must be clean and 
free of scratches. Make sure that the o-ring is seated in 
the designated groove in the cap and is not squeezed.  

Lock the device after that properly.  

Fig. 3 battery case 

NOTE  -

 An incorrect usage may cause a leak out of batteries 

and so a damage the device! 

NOTE -

 Only use a battery of type CR 2450. 

NOTE -

 Make sure that the battery is connected correctly with 

the corresponding contacts in the battery tray. 

NOTE -

 Never try to charge battery, demount or short-circuit it. 

NOTE -

 Use only batteries with UL certification. 

NOTE -

 Keep the battery away from heat and unshielded 

flame. 

5. Commissioning 

 

The device has been installed properly. 

 

The device does not have any visible defect. 

 

The device is operated within the specification  
(according to the data sheet).  

6. Operation 

6.1 Operating and display elements 

Fig. 4 Touch pad 

Select / ON-button:

 

- switch-on of the device 
- choosing of the pressure units 
- calibration of starting point 
- configuration of the switch-off automatic 

Function / OFF-button

- switch-off of the device 
- scrolling in the menu system 

The indication of the measured value as well as the configuration 
of  the  individual  parameters  occurs  menu-driven  via  the  LC 
display. The individual functions can be set with the help of two 
miniature push buttons located in the front. 

The  menu  system  is  a  closed  system  allowing  you  to  scroll 
forward  through  the  individual  set-up  menus  to  navigate  to  the 
desired  setting  item.  All  settings  are  permanently  stored  in  an 
Flash-EPROM and therefore available again even after a battery 
change. 

6.2 Structure of the menu system 

6.3 Menu list 

1 MIN

 

Minimum pressure display 

The minimum pressure during the 
measurement process will be shown in the 
display. 
To delete the stored value push the 
Select/ON-button. It appears 

 in 

the display, the value has been recessed. 

2 MAX

 

Maximum pressure display 

The maximum pressure during the 
measurement process will be shown in the 
display. 
To delete the stored value push the 
Select/ON-button. It appears 

 in 

the display, the value has been recessed. 

3 UNIT

 

Setting of the pressure unit 

Possible units are: bar, mbar, psi, MPa, 
mH

2

The desired unit may be selected and 
activated with the Select/ON-button. 

 

Depending on the nominal pressure 
range and the accuracy of the device, 
perhaps not all available units could 
be used. 

4 ZERO

 

Zero point 

If you detect a shifting of the measured 
value deviating from the offset, the display 
can be re-calibrated via pushing the 
Select/ON-button. The display shows 

, the value has been recessed. 

Differs the zero point from the ambient 
pressure, it is a pressure reference 
necessary. 

5 SW OFF

 

Configuration of the switch-off 
automatic 

The desired switch-off automatic may be 
selected through the Select/ON-button. 
Allocation of the programmable values: 
"0": switch-off automatic is not active 
"1" 

– "5": switch-off automatic after 1 up to 

5 minutes 

The menu system will be leaved automatically after 10 
seconds; the last sett value has been saved. If you scroll all 
menu points you will leave the menu system after 

SW OFF

 

After configuring the unit, the conversion of the pressure 
range into the new unit will only occur after leaving the 
menu system. Depending on the pressure range, 
probably not all available units can be used. 

 

  Type designation 

Ordering code 

Serial number 

 

 

 

Display 

Function /  

Select /  

OFF-button 

ON-button 

Отзывы: