Oil-Fired BCS

Page 13

BOCK OIL-FIRED WATER HEATER

Содержание Oil-Fired

Страница 1: ...ter temperature is needed in part of the water system automatic temperature limiting devices must be used on all lines to water taps WARNING Flammable vapors may be drawn to this water heater from oth...

Страница 2: ...40 126 9 3 4 3 4 1 90 136 61 20 6 54 18 120 60 305 51E BCS 50 152 1 1 1 1 1 90 161 59 24 6 11 18 120 60 345 120E BCS 113 155 1 1 1 2 2 90 163 67 311 2 6 19 22 120 60 705 190E BCS 113 190 1 35 1 2 2 90...

Страница 3: ...ally out of the west or north is the preferred wall for installa tion This reduces the likelihood that the Balanced Flue application will be operating against high winds and severe cold when it is cyc...

Страница 4: ...EMENT NOTE Locate the heater so it is not subject to physical damage from moving vehicles or flooding DO NOT INSTALL THE WATER HEATER ON COM BUSTIBLE FLOORING Place on noncombustible flooring and main...

Страница 5: ...d up in the water heater and result in tank failure If this water heater is installed in a closed system or if backflow preventers and pressure regulators are installed a properly sized expansion tank...

Страница 6: ...astat with immersion well is packed with the burner The thermostat is factory set at 120 F for residential use The maximum setting for 20 32 40 and 51E BCS models is 160 F for 120 and 190E BCS models...

Страница 7: ...eturn line should stop slightly above the suction line Use a minimum of fittings Make tubing bends with as large a radius as possible DO NOT USE COMPRESSION FITTINGS Use caution in the final connectio...

Страница 8: ...to see that the burner control locks out in the time specified on the control Reattach the wire and reset the control The burner should restart Note You may have to wait a minute before resetting the...

Страница 9: ...lter and have the oil tank checked for sediment Clean the tank if necessary 4 The system should be checked with combustion instruments for safe and efficient operation 5 Keep the oil tank full to prev...

Страница 10: ...tes runs for a short time 10 20 seconds and then goes out on safety replace the flame detector If the burner still runs only a short time replace the control 6 If you smell oil or combustion products...

Страница 11: ...120E BCS Carlin 1 1 x 70A 190E BCS Carlin 1 35 x 70B The only controls acceptable for use with these models are as follows For normal household applications Burner Carlin EZ1 with 15 minute post purge...

Страница 12: ...ntal or consequential damages so the above limitations or exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to stat...

Страница 13: ...Oil Fired BCS Page 13 BOCK OIL FIRED WATER HEATER...

Страница 14: ...Page 14 Oil Fired BCS Balanced Flue BURNER WIRE DIAGRAM Models 20 32 40 51 120 190E BCS Carlin EZ Temp Control...

Страница 15: ...Oil Fired BCS Page 15 EXPANSION TANK OPTIONAL IF ANY OF THESE DEVICES ARE USED A PROPERLY SIZED EXPANSION TANK MUST BE INSTALLED...

Страница 16: ...h space and water Bock Radiant uses functional hot water and avoids boiler type overheating that wastes energy Bock Radiant eliminates using a boiler during warm months and lets ecomonic domestic hot...