background image

Oil-Fired BCS

Page 11

COMPANY’S RESPONSIBILITY

The company’s responsibility is to repair or replace, at our option, with the prevailing compa-
rable Bock model, any part of the equipment, including the tank, sold by the company which
proves to be defective in material or workmanship during the warranty period, when installed
in accordance with applicable codes and ordinances, and operated and maintained in accor-
dance with our instructions, subject to the conditions and exceptions indicated below. Our lia-
bility, in the event of leakage or other malfunction, is strictly limited to repair or replacement
of the defective heater or part, as provided herein. We are not responsible hereunder for inci-
dental property damage or personal injury, consequential costs or damage. Equipment that is
repaired or replaced will carry the unexpired portion of the original equipment warranty.

BURNER AND CONTROLS

Any burner and/or controls used on a Bock water heater other than the ones recommended by
Bock Water Heaters, 

and listed by Underwriters Laboratories, Inc., will void the water

heater warranty

. Bock Water Heaters specifies burners and controls on the basis of safety, re-

liability and performance. Only the following burners and controls have been tested and ap-
proved by Bock Water Heaters and Underwriters Laboratories, Inc., to meet the stringent
standards required by both: 

20e-BCS: Carlin 0.4 x 60A; 32E-BCS: Carlin 0.75 x 70A; 

40E-BCS: Carlin 0.85 x 70A; 51E-BCS and 120E-BCS: Carlin 1.1 x 70A; 
190E-BCS: Carlin 1.35 x 70B.

The only controls acceptable for use with these models are as follows:

For normal household applications:

Burner: Carlin EZ1 with 15-minute post-purge and nozzle heater.

Temperature Control (aquastat): 20, 32, 40, 51E-BCS—Carlin EZ-Temp 90000B

120E-BCS—Carlin EZ-Temp 90000C, 90300B
190E-BCS—Carlin EZ-Temp 90300B

OWNER’S RESPONSIBILITY

At the company’s request, the owner is to return to the factory at Madison, WI, any part, in-
cluding the tank, defective in material or workmanship, and pay all transportation charges for
such return parts and for replacement parts sent from the factory to the owner. The owner will
pay all labor charges for the removal and installation of such parts, including the tank. Any
replacement water heater furnished under this warranty shall remain in warranty only for the
unexpired portion of the original warranty. The owner will have annual inspections of the
anode rods. Bock Water Heaters requires paid receipts to show maintenance of anodes on glass
lined tank claims.

EXCEPTIONS

This warranty will not apply to tanks or parts subject to misuse, abuse, neglect, alteration,
accident, excessive temperature, excessive pressure, lime, silt or sediment accumulation,
corrosive atmosphere, the removal of the magnesium anode rods, noise, odor, rusty water, 
the installation of an insulation blanket, installation outside of the United States (excluding
Canada), or on which the serial numbers have been altered. The warranty also does not apply
when the water heater is installed without a new temperature and pressure relief valve and is
not installed in accordance with local codes and ordinances.

Содержание Oil-Fired

Страница 1: ...ter temperature is needed in part of the water system automatic temperature limiting devices must be used on all lines to water taps WARNING Flammable vapors may be drawn to this water heater from oth...

Страница 2: ...40 126 9 3 4 3 4 1 90 136 61 20 6 54 18 120 60 305 51E BCS 50 152 1 1 1 1 1 90 161 59 24 6 11 18 120 60 345 120E BCS 113 155 1 1 1 2 2 90 163 67 311 2 6 19 22 120 60 705 190E BCS 113 190 1 35 1 2 2 90...

Страница 3: ...ally out of the west or north is the preferred wall for installa tion This reduces the likelihood that the Balanced Flue application will be operating against high winds and severe cold when it is cyc...

Страница 4: ...EMENT NOTE Locate the heater so it is not subject to physical damage from moving vehicles or flooding DO NOT INSTALL THE WATER HEATER ON COM BUSTIBLE FLOORING Place on noncombustible flooring and main...

Страница 5: ...d up in the water heater and result in tank failure If this water heater is installed in a closed system or if backflow preventers and pressure regulators are installed a properly sized expansion tank...

Страница 6: ...astat with immersion well is packed with the burner The thermostat is factory set at 120 F for residential use The maximum setting for 20 32 40 and 51E BCS models is 160 F for 120 and 190E BCS models...

Страница 7: ...eturn line should stop slightly above the suction line Use a minimum of fittings Make tubing bends with as large a radius as possible DO NOT USE COMPRESSION FITTINGS Use caution in the final connectio...

Страница 8: ...to see that the burner control locks out in the time specified on the control Reattach the wire and reset the control The burner should restart Note You may have to wait a minute before resetting the...

Страница 9: ...lter and have the oil tank checked for sediment Clean the tank if necessary 4 The system should be checked with combustion instruments for safe and efficient operation 5 Keep the oil tank full to prev...

Страница 10: ...tes runs for a short time 10 20 seconds and then goes out on safety replace the flame detector If the burner still runs only a short time replace the control 6 If you smell oil or combustion products...

Страница 11: ...120E BCS Carlin 1 1 x 70A 190E BCS Carlin 1 35 x 70B The only controls acceptable for use with these models are as follows For normal household applications Burner Carlin EZ1 with 15 minute post purge...

Страница 12: ...ntal or consequential damages so the above limitations or exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to stat...

Страница 13: ...Oil Fired BCS Page 13 BOCK OIL FIRED WATER HEATER...

Страница 14: ...Page 14 Oil Fired BCS Balanced Flue BURNER WIRE DIAGRAM Models 20 32 40 51 120 190E BCS Carlin EZ Temp Control...

Страница 15: ...Oil Fired BCS Page 15 EXPANSION TANK OPTIONAL IF ANY OF THESE DEVICES ARE USED A PROPERLY SIZED EXPANSION TANK MUST BE INSTALLED...

Страница 16: ...h space and water Bock Radiant uses functional hot water and avoids boiler type overheating that wastes energy Bock Radiant eliminates using a boiler during warm months and lets ecomonic domestic hot...

Отзывы: