background image

 

 

ENGLISH (US)

 

 

Page 6 of 28 

OTH-SEM250-0356 Rev D

 

2.2.

 

Requirements 

The BBI Webserver Virtual Machine (VM). 
SQL Server installed. 

2.3.

 

Nomenclature 

Virtual Machine: The BBI Webserver VM that is installed on the hospital-provided server and 

provides a working environment for the BBI Web application.  
Pressure ulcers also are called pressure injuries, decubitus ulcers, bed sores or pressure sores. 

2.4.

 

Indications for Use 

The Provizio SEM Scanner and Provizio SEM Scanner S are intended to be used by healthcare 

professionals as an adjunct to the standard of care when assessing the heels and sacrum of 

patients who are at increased risk for pressure ulcers. 

2.5.

 

Contraindications 

Do not use on broken skin.  

2.6.

 

Intended User Profile 

The system is intended for use by healthcare professionals. 

2.7.

 

Adverse Effects 

There are no know adverse effects using the scanner. 

2.8.

 

Warranty and Disclaimer 

This manual is intended to provide instructions on the proper use of the SEM.  It should be 

used in conjunction with the appropriate training.  Bruin Biometrics LLC (BBI) warrants the 

Provizio SEM Scanner against defects in materials and workmanship for three (3) years from the 

date of purchase from BBI or its subsidiaries.  This warranty is given only to the original 

purchaser of the SEM Scanner.  BBI’s obligation under the warranty is to provide for repair, or 

at its option, to provide a replacement product.  No other remedy is obligated by this 

warranty.  All special, incidental, and coincidental damages are excluded.   
There are no conditions associated with varnishing, enameling, oxidation and similar protective 

finishes, as well as covering with sealing compounds that can re-plasticize at temperatures to be 

expected during normal operation. 
To request repair or replacement under this warranty, purchasers should contact their local 

Customer Service provider.   

Содержание Provizio SEM

Страница 1: ...6 Rev D PROVIZIOTM SEM SCANNER SCANNER S GATEWAY SYSTEM SUPPORT MANUAL Bruin Biometrics LLC 10877 Wilshire Blvd Suite 1600 Los Angeles CA 90024 USA Phone 310 268 9494 E mail customerservice bruinbiome...

Страница 2: ...2 8 1 Exclusions 7 2 8 2 Disclaimer of Additional Warranties 7 2 9 Table of Symbols 8 3 SETUP INSTRUCTIONS INSTALL VMWARE PLAYER 9 4 CREATE VIRTUAL MACHINE 10 5 WEB SERVER VIRTUAL MACHINE SETUP 12 6...

Страница 3: ...CONFIGURATION 19 10 1 Install the Webserver 19 10 2 Navigate to the Gateway 19 10 3 Configure the Gateway 19 10 4 Assign roles 20 11 HANDHELD SUPPORT 21 11 1 Electromagnetic Environment 21 11 2 Elect...

Страница 4: ...r of a physician or other licensed health practitioner 1 1 Warnings WARNING The standard of care should be followed for reducing the risk of developing pressure ulcers Readings from the Provizio SEM S...

Страница 5: ...the risk of explosion the Provizio SEM Scanner should not be used in the presence of flammable anesthetic agents WARNING The Provizio SEM Scanner S will not operate correctly without first installing...

Страница 6: ...w adverse effects using the scanner 2 8 Warranty and Disclaimer This manual is intended to provide instructions on the proper use of the SEM It should be used in conjunction with the appropriate train...

Страница 7: ...reof a that have been subject to misuse neglect or accident b that have been damaged by causes external to the Warranted Product c that have been used in violation of the BBI Instructions for Use d on...

Страница 8: ...ed Caution or warning Dispose of this equipment according to local regulations for electrical and electronic waste disposal Manufactured By Drip Proof Equipment IPX1 The Provizio SEM Scanner enclosure...

Страница 9: ...he terms in the License Agreement and then select Next to continue 4 Select the checkbox next to Enhanced Keyboard Driver and then select Next to continue 5 Uncheck both checkboxes on the User Experie...

Страница 10: ...o continue 10 Set the Maximum disk size GB to 60 0 GB a Leave the default setting Split virtual disk into multiple files b Select Next to continue 11 Select the Customize Hardware button a Edit the Me...

Страница 11: ...e the CTRL ALT DEL key on VMware Player menu bar to bypass the lock screen 22 Enter the password to continue 23 When the Networks window is displayed select the Yes option 24 Right click the windows s...

Страница 12: ...ework 4 7 ii HTTP Activation found in NET Framework 4 7 WCF Services 1 In the new dialog box Add features that are required for HTTP Activation select the Add Features button iii IIS Hostable Web Core...

Страница 13: ...under Allow in the Permissions for IIS_IUSRS section e Select Apply f Select OK ii Select OK to continue 9 Select the Windows button in the bottom left corner and type inetmgr a Open the Internet Info...

Страница 14: ...of 28 OTH SEM250 0356 Rev D 6 Additional Setup Steps 1 Copy the contents of PN XXXX BBI Socket Installer to the Web VM 2 Launch the BruinSocket Setup install file a Select Next b Select Next c Select...

Страница 15: ...mb drive into the host 3 Navigate to the file location of the saved BBI_SEM250_WEB VM a Ie C Users Host Documents Virtual Machines BBI_SEM250_WEB 4 Copy the BBI_SEM250_WEB folder 5 Paste the BBI_SEM25...

Страница 16: ...ase engine server by right clicking the database engine and selecting Restart 7 Once the restart is complete expand the Security folder in the database engine right click the Logins folder and select...

Страница 17: ...ase Engine as used in the previous steps 4 Select SQL Server Authentication for Authentication 5 Enter the BBI SQL username and password and select Connect 6 If authentication was successful and the B...

Страница 18: ...Active Directory Users and Computers 3 Identify and navigate to the desired forest to contain the new BBI LDAP server roles e g cpx local 4 Right click the Users folder and select New and then Group...

Страница 19: ...dow f Enter the following command g telnet IP of LDAP server port of LDAP Server e g telnet 192 168 1 11 389 h If the command prompt displays a blank command prompt screen with the title Telnet IP of...

Страница 20: ...st LDAP Connection button and verify that a dialog box is displayed that says Connection was successfully established 6 Select Next to continue 7 Confirm the values and select Finish to proceed 8 Logo...

Страница 21: ...ns Test Compliance Electromagnetic Environment Guidance RF emissions CISPR11 Group 1 The Provizio SEM Scanner 250 device uses RF energy only for its internal function Therefore its RF emissions are ve...

Страница 22: ...ltage variations on power supply input lines IEC 61000 4 11 5 UT 95 dip in UT for 0 5 cycle 40 UT 60 dip in UT for 5 cycles 70 UT 30 dip in UT for 30 cycles 5 UT 95 dip in UT for 5s 5 UT 95 dip in UT...

Страница 23: ...where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer and d is recommended separation distance in meters m Field strengths from fixed RF tr...

Страница 24: ...in Table 5 Table 5 Separation Distance Separation distance according to frequency of transmitter meters Rated maximum output power of transmitter W 150 kHz to 80 MHz P d 2 1 80 MHz to 800 MHz P d 2 1...

Страница 25: ...atability 1 0 2 SEM Value units Storage The Provizio SEM Scanner should only be stored at temperatures ranging from 4 F 20 C to 113 F 45 C at 5 to 90 relative humidity non condensing Operating Conditi...

Страница 26: ...ministrator for the correct URL for your institutions installation I cannot save settings to the SQL Server Ensure you have sufficient SQL Server privileges to update settings SQL settings were not ve...

Страница 27: ...ails Re enter the SQL settings and re verify Ensure you have sufficient SQL Server privileges to update settings Telnet connection to the LDAP server fails Re enter the SQL settings and re verify Ensu...

Страница 28: ...ts Refer to https sem scanner com patents for more information 2019 Bruin Biometrics LLC or its affiliates All rights reserved Bruin Biometrics LLC 10877 Wilshire Blvd Suite 1600 Los Angeles CA 90024...