4.6.11. Diagnostics
After the device interface has been enabled
, the “
Diagnostics
” button
is available. If you
click on the „Diagnos
tics
“ button, the diagnosis window appears.
The diagnosis cannot be
performed simultaneously with the range function.
NOTICE:
A correct diagnosis requires an adaption of data between function chart and equipment
configuration. A missing logic plan or inconsistencies between the existing logic plan and the
equipment configuration only allow a restricted diagnosis.
In this case, the function “Function
Module Diagnostics
”
is not available.
Figure 78 Diagnostics window of functional module
The diagnosis window consists of the following sheets:
Process image:
Shows the statuses of all addresses of the input image and the output image in
the SCU module. The CRC of the active configuration is displayed together with the status of the
internal transmission meter. The meter reading increases with every transmission to the SCU
module and, can serve as reference for documentation purposes.
System info
: System information on the SCU module:
Parameter
Description
General information
–
CRC
CRC signature for theprogramme and the parameter
data
Configuration
–
CRC
CRC signature fort he parameters
Programme-CRC
CRC for the Programme
Transmission meter
Status of the internal transmission meter. The meter
reading increases with every transmission to the SCU
module,and can serve as reference for documentation
purposes.
Serial number
Current serial number of the equipment
Version number
Version number of the firmware