Programming manual SCU-series
HB-37500-820-10-12F-EN SCU Programming manual
Page 91 of 252
Status: 19.03.2021
4.6.3. Embedding not pre-defined Slaves
➔
This option will be available in the later versions of the manual.
➔
To embed not pre-defined Slaves, please contact the manufacturer
4.6.4. Adding input elements
The input elements create the digital connection between one or more connected sensors or
further subordinate switching devices in the
system
. Except the selection switch to select the
operating mode, every input element provides one logic output signal
“0” or “1” for further
processing in the SPC.
The input elements are automatically added to the terminal scheme or to the circuit diagram where
they are processed. In the terminal scheme, the input elements are inserted from the browser.
The resource management of the function block elements of the SCU system manages the
available elements whose number can be restricted.
If no further elements are available during the programming of the terminal scheme, no blocks are
available to add the corresponding modules or function blocks. The available blocks are displayed
in the library. These resources can be released again bydeleting the corresponding function
blocks. To delete a block, select the block from the browser or from the work surface. Click on it
with the right mouse button, and select “
Delete
“ or press “Del”.
4.6.5. Inserting output elements
The output elements create the digital connection between one or more external circuit in the
s
ystem
.
This element of the logic plan has direct influence on the drive to be monitored,
Furthermore, it can be determined, how external switching devices shall be monitored. Every
output element is
controlled by a logic input signal “0” or “1” via the function chart.
The output elements are added in the terminal scheme or in the circuit diagram. The output
elements are edited in the function scheme. In the terminal scheme, the output blocks are dragged
from the browser and dropped.
By the automatic monitoring of the resources of the function blocks of the SCU module, only the
available elements are enabled in the programme. If no resources for the monitoring program are
available in the safety module the commands to insert the corresponding components or function
blocks is deenabled (The library functons are not available.). This is the case if p. ex. all digital
outputs of SCU module are occupied. These resources can be released again by deleting the
respective function blocks.