background image

 

 

Industry 30 

Weighing indicator 

 

                                     

 

 

 

USER MANUAL 

 

 

 

 

 

Edition:10052001A

Содержание Industry 30

Страница 1: ...Industry 30 Weighing indicator USER MANUAL Edition 10052001A...

Страница 2: ...of the indicator is prohibited by Non professional staff WARNING Pls make sure the weighing display have good ground in using WARNING The indicator is the static and sensitive equipment cut off the po...

Страница 3: ...nction 11 3 5 Total function 11 3 6 Print function 13 3 7 Hold function 13 4 Calibartion and Technical parameter setting 13 4 1 Enter calibartion 13 4 2 Caliaration 14 4 3 Technical parameter setting...

Страница 4: ...format S N G W N W Tare Date Time Options Pinter RS232 RS485 serial interface or second display I O 4 20mA 1 2 technical parameter Accuracy class 5000 e Resolution display 30 000 ADC 2 000 000 Zero st...

Страница 5: ...2 1 3 Outline mm...

Страница 6: ...means low battery pls charge it in time 3 the light turns to red during charging 4 when the light turns to green means fully charged 5 if battery is not used for long time take it out to avoid the lea...

Страница 7: ...wo methods connection between load cell and indicator A quick disconnect as below B Terminal trip connection inner connection 1 the exciting voltage for the load cell is 5VDC the largest output curren...

Страница 8: ...IN EXC EXC voltage 2 3 Communication interface RS232 DB9 Pin or 3 Pin DB9 definition 5 4 3 2 1 9 8 7 6 Pin function and definition as bellows DB9 joint Definition Function 2 TXD Sending data 3 RXD Re...

Страница 9: ...5 output A port B RS485 output B port 2 4 4 20mA output Technical parameters Resolutions 1 1000 Outside Load 100 350 Connection 1 Inside connection 4 20mA load input port connect with I of J2 Ground p...

Страница 10: ...elay output signal function The indicator can output 4 signal connect with the outside equipment the indicator can perform automatic control function and upper limit and lower limit alarm function Per...

Страница 11: ...light on And can connect with buzzer There would be alarm remind when overload C33 2 Feeding control application For hopper scales The target is between is 50 500kg the Output card can perform open an...

Страница 12: ...1 st output signal pin Out1 6 pin 1 st output signal pin Out1 2 pin 2 nd output signal pin Out2 7 pin 2 nd output signal pin Out2 3 pin 3 rd output signal pin Out3 8 pin 3 rd output signal pin Out3 4...

Страница 13: ...10 3 Basic operation 3 1 keypad LED instruction Weighing data kg kg lb lb...

Страница 14: ...counting status TOTAL Go to accumulation mode Keys function keys Key name Key function Print 1 work with ZERO TARE ON OFF key to perform many functions 2 Print Zero Zero the weight within tolerance T...

Страница 15: ...off after power on the indicator show 000000 999999 After self inspection It go to the weighing mode Pls check it whether 6 bits LED LCD display and the status light is good or not 3 3 Zero operation...

Страница 16: ...AL key display n it is the accumulating times then show total weight there are 8 digits totally It shows the first 4 digits then the last 4 digits For example the first 4 digits is 0012 the last 4 dig...

Страница 17: ...ighing mode 4 If you want to weigh different goods at weighing mode put the sample on the platform scales press Count the indicator show 0 Press Count hold it and then press ON OFF the indicator show...

Страница 18: ...CK EXIT CALIBRATION POWER 4 2 Step of calibration operation According to the second method which can enter setting menu C01 C39 step Method of operation display Remark 1 C01 After you enter calibratio...

Страница 19: ...g 0100 00 6 press press press press C05 C05 0 C05 1 CAL 9 0000 00 Zero calibration Option 0 no need zero calibration 1 need zero calibration calibration zero please choose 1 and ensure scale is empty...

Страница 20: ...ter the above parameters setting finish please do not set default parameters to avoid the original setting parameters is lost 4 3 Application function parameters setting chart Function Setting Item pa...

Страница 21: ...pplication for materials testing such as tension and pulling force Date hold it shows current weight value Mainly application for animal weighing Kg lb conversion C12 Kg lb conversion C12 0 stop kg lb...

Страница 22: ...g format connect computer 5 PC second display continuous sending format C19 Baud rate option 0 1200 1 2400 2 4800 3 9600 Zero range C20 Manually zero range Option 0 close manually zero setting 1 1 max...

Страница 23: ...ero tracking time Options 0 close zero tracking time 1 1 second 2 2 seconds 3 3 seconds Overload range C24 Overload range option 00 close overload range 01d 99d remark d division Negative display C25...

Страница 24: ...s setting dynamic filter strength carefully the No is bigger more stable if the loaded weight shake not too much The setting is less than 3 C29 Noise filter option 0 close noise filter 1 1 digital fil...

Страница 25: ...add C34 Communication add C34 0 99 Add Code Wireless communication C35 C35 0 99 signal Gravity of calibration location C36 C36 9 7000 9 9999 Gravity of destination C37 C37 9 7000 9 9999 Version No C3...

Страница 26: ...K S 1 2 3 4 5 6 State A Bits0 1 2 0 1 2 Decimal point position 1 0 0 XXXXXX0 0 1 0 XXXXXXX 1 1 0 XXXXX X 0 0 1 XXXX XX 1 0 1 XXX XXX Bits3 4 Division 0 1 X1 1 0 X2 State B BitsS function Bits0 gross 0...

Страница 27: ...us ST standstill US not standstill OL overload S2 weight mode GS gross mode NT net mode S3 weight of positive and negative or S4 kg or lb Data weight value including decimal point CR carriage return L...

Страница 28: ...conversion G G W Check gross weight at net weight mode R command receive data format 5 4 Print format ID NO 004 Serial No Date XX XX XX yy mm dd Time XX XX XX hh mm ss GROSS 8 88kg gross weight TARE 2...

Страница 29: ...sted or not foot is kept level or not 2 check load cell connection 3 checking load cell check input and output resistance to judge it is good or not ERR1 During calibration not input the weights or th...

Страница 30: ...ator firstly before plug and unplug 6 3 Restore default parameter Enter to calibration Set C07 1 Press PRINT then press COUNT to exit saving setting All parameter will back to default Note Pls do not...

Страница 31: ...l zero 10 C22 Zero tracking range 0 5 C23 Zero tracking time 1 C24 Overload range 9 C25 Negative range 10 C26 Standstill time 1 C27 Standstill range 2 C28 Dynamic filter 0 C29 Noisy filter 2 C30 Print...

Страница 32: ...hina DC9V PCS 1 US DC9V PCS 1 UK DC 9V PCS 1 EU DC9V PCS 1 AU DC9V PCS 1 OTHERS PCS 1 5 USER MANUAL PCS 1 6 RS232 3 PIN OR DB9 PCS 1 7 LOADCELL PLUG 5 PIN Quick disconnect PCS 1 8 Signal cable 5 3 cor...