Страница 1: ...IDS701 Weighing Indicator User manual Manual usuario BBG ref BULL...
Страница 2: ...the the weighing indicator is prohibited by Non professional staff WARNING Pls make sure the weighing display well earthing WARNING The indicator is electrostatic sensitive device pls power off durin...
Страница 3: ...between indicator and load cell 6 2 2 Connection of interface 6 3 Basic operation 6 3 1 Display and key instruction 6 3 2 Power on 8 3 3 Zero function 8 3 4 Tare function 8 3 5 Accumulating function...
Страница 4: ...remind charge and stop charge controlled PC communication Automatically power off 1 2 Optional function accumulating function conversion kg lb animal weighing printing function with time 1 3 Technica...
Страница 5: ...2 when the red battery light is on and flashes it means low battery You should charge battery in time 3 Charge time 10 12 hours And it works 45 hours 4 When the battery light turns green it means full...
Страница 6: ...our pcs 350 load cell at most both four and six wire load cell are ok To make it simple we use quick disconnect Or standard plug As belows Quick disconnect connection 2 2 Connection of interface RS232...
Страница 7: ...01 User Manual Page 6 of 25 3 Basic operation 3 1 Key and display IDS701 Weighing indicator display instruction LED display instruction Weighing data display Total accumulating Manual usuario BBG ref...
Страница 8: ...zero weight Battery Using battery Hi Over setting weight OK Within setting weight Lo Below setting weight Decimal point Key s function Key symbol Key name Key function SET Work together with zero tare...
Страница 9: ...nter calibration and function setting 3 2 Power on Power on and indicator perform self checking and go to weighing mode 3 3 Zero setting Within zero range press zero indicator weighing is cleared When...
Страница 10: ...es then display total weight There are 8 data totally It shows the first 4 digital then the last 4 digital For example the first 4 digital is 0012 the last 4 digital is 34 56 It means the actual weigh...
Страница 11: ...weighing mode Press still then press display the lock weight hold Light is on At that time you load or unload stuff the weight keep still Data hold display the lock weight Press still then press disp...
Страница 12: ...ng menu 1 when the span is not pressed down Press Press still and then press enter C08 C39 setting 2 Take out the sealing screw on the back of indicator then press down the span Press still and then p...
Страница 13: ...imal digits option 0 1 2 3 4 Select decimal digit example two decimal point C02 2 4 press press press or C03 C03 1 C03 5 Set graduation option 1 2 5 10 20 50 Select required graduation example graduat...
Страница 14: ...apacity setting add suitable weight on scale close to the max capacity heavier than 10 max at least For example the weight is 80kg As bellows enter loading calibration count down over indicator shows...
Страница 15: ...eep still within 10 min power off automatically 30 keep still within 30 min power off automatically 60 keep still within 60 min power off automatically Power saving setting C10 Power saving setting op...
Страница 16: ...C15 indicator will show inner code Date and time C16 Date Enter C16 you can direct to set the current date from left to right year month day C17 Time Enter C16 you can direct to set the current date...
Страница 17: ...10 max capacity 20 20 max capacity Automatic zero tracking C22 Automatic zero tracking range option 0 0 close automatic zero tracking 0 5 0 5d 1 0 1 0d 2 0 2 0d 3 0 3 0d 4 0 4 0d 5 0 5 0d remark 1 d...
Страница 18: ...truction Dynamic filter is collecting the data filter before loaded weight stable When loaded weight easily shaking for example animal you can set this filter to make weight display more stable option...
Страница 19: ...C30 1 mm dd yy C30 2 dd mm yy C30 3 yy mm dd 5 Output data format 5 1Computer continuous sending format CR LF S 1 S 2 S 3 Data S 4 S1 weight status ST standstill US not standstill OL overload S2 weigh...
Страница 20: ...K S 1 2 3 4 5 6 State A Bits0 1 2 0 1 2 Decimal point position 1 0 0 XXXXXX0 0 1 0 XXXXXXX 1 1 0 XXXXX X 0 0 1 XXXX XX 1 0 1 XXX XXX Bits3 4 Division 0 1 X1 1 0 X2 State B BitsS function Bits0 gross 0...
Страница 21: ...ace can receive simple ASCII command Command word and role as follows Command name role T Tare off command Save and clear tare Z Zero command Zero the gross weight P Print command Print the weight R R...
Страница 22: ...ax capacity 2 wrong connection with load cell or no connection with it 3 load cell unworkable 1 decrease loaded weight 2 check load cell connection 3 checking load cell check input and output resistan...
Страница 23: ...l wrong pls replace the PCB ERR4 During calibration single is unstable Ensure added weight and scale is stable start calibration ERR5 EEPROM check error change PCB 6 2 Daily maintenance 1 In order to...
Страница 24: ...al and have not scale calibration Default parameter form parameter instruction Default value C01 Calibration unit 1 C02 decimal digits 0 C03 Division value 1 C04 Max capacity 10000 C05 Empty scales ca...
Страница 25: ...19 Serial interface Baud rate 3 9600 C20 Manual zero setting 2 C21 Initical zero setting 10 C22 Automatic zero tracking range 0 5 C23 Automatic zero tracking time 1 C24 Verload range 9 C25 Negative di...
Страница 26: ...s bag PCS 1 4 Power supply GB DC9V PCS 1 US DC9V PCS 1 UK DC 9V PCS 1 EU DC9V PCS 1 AU DC9V PCS 1 others PCS 1 5 User s manual PCS 1 6 RS232 3 core quick connecter PCS 1 7 Load cell joint 5 core quick...