background image

1

XRF-T.2

LED

 50 

 121 

 23 

5

i

 50 

 121 

 23 

 4.2 

 5.7 

 4.2 

 22 

 106 

8k2

i

1 2

ON

1 2

ON

1 2

ON

1 2

ON

IN1

IN2

1)

IN1

IN2

1)

8k2

8k2

IN1

IN2

1)

8k2

IN1

IN2

1)

8k2

1  2 3  4

1  2 3  4

1  2 3  4

1  2 3  4

 

 

Transmitter to XRF wireless transmission system

Original operating instructions

Intended use: Monitoring 1 or 2 safety edges and switches on doors and gates, in combination with a receiver XRF

1

Installation 

(Cable routing, strain relief)

ENGLISH

404300E

01/21

Transmitter (Tx)

Opening cover
(lift, then slide)

Battery

CR2450N

DIP-

switch

Push

button

Space 

to open cover

  Determine the cable routing

   Break out the respective part of the cover 

if necessary

  

Punch hole into the grommet

  

Insert cable

…  or use holes 

in the base plate 

Break out … 

Hint:

Cable Ø: 3.1 – 5.2 mm

or

Saftey instructions

•   Read these operating instructions thoroughly before putting the device into 

operation and keep them for future reference. 

•   Do not use this product other than for its specified application.

•  Only trained and qualified personnel may install and initialize the device.

•   Only authorized factory personnel may perform hardware/software changes or 

repairs to the product. 

•   Failure to follow these safety precautions may cause damage to sensor or objects, 

serious personal injury, or death. 

•   It is the responsibility of the equipment manufacturer to carry out a risk assess-

ment and to install the system, in compliance with applicable local, national and 

international regulations, safety standards, codes and laws as well as the 

Machinery Directive 2006/42/EC, should this apply.

•   Always consider the safety functions of your applications as a whole, never just in 

relation to one individual section of the system.

•   The installer is responsible for testing the system to ensure it meets all applicable 

safety standards.

•   Safety devices that are classified as Category 2 according to EN ISO 13849-1 must 

be tested regularly – at least once per cycle.

•   If the safety device is not requested operationally at least once a year, it must be 

checked manually by the operator at least once a year.

•   Pay attention to all local relevant electrical safety regulations.

•   Protect the device with a housing against contamination or harsh environments.

•  This device contains batteries.

•  Observe the local regulations for battery disposal.

•   After accessing the inside of the device, ensure the cover/protection seal is 

closed tightly to achieve designated protection rating.

= safety edge

(factory setting)

= switch       (NO or NC: see 2.2)

DIP switch setting according to sensors (safety edge, switch)
a change of the DIP switch will be confirmed by a (slightly delayed) flash of the LED

2.1  DIP switch setting

1)

  

IN2 is only active when used with dual channel receiver (see receiver manual)

2

Wiring / set-up

Wire cross section 0.25 – 0.75 mm

2

Отзывы: