LED 1

Wireless single channel signal transmission system for safety edges 

Original operating instructions

Intended use: Monitoring safety edges on doors and gates

1

Safety instructions

ENGLISH

404169E

10/20

Receiver (Rx)

•  Read these operating instructions thoroughly before putting the device into 

operation and keep them for future reference.

•  The assembly, commissioning, modifications and extensions may only be comple-

ted by an experienced electrician.

•  Before commencing work, remove the power supply from the device/installations!

•  During the operation of electrical components 

– e. g. in the case of a short circuit hot and ionised gases can be

 

emitted 

– protection covers must not to be removed.

•  Pay attention to all local relevant electrical safety regulations.

•  Disregard of the safety regulations can cause death, severe injuries or extensive 

damage.

•  Devices that are classified as Category 2 according to EN ISO 13849-1 must be 

tested regularly – at least once per cycle.

•  It is the responsibility of the equipment manufacturer to carry out a risk assess-

ment and to install both the detector and the equipment in compliance with 

applicable national and international regulations and safety standards, as well as 

the Machinery Directive 2006/42/EC, should this apply.

Receiver 

Tx1

Tx2

Before commencing the installation or assembly complete the following safety 

precautions:

•  Check the voltage data on the label of the switching device.

•  Ensure that the device/installations can not be switched on.

•  Determine that the power supply is disconnected.

•  Protect the device with a housing against contamination or aggressive 

environments.

•  Connect all operating and switching voltages to the same fuse. 

•  Connect the operating voltage to the same circuit as the industrial door controller. 

•  Disconnect device from mains in the event of a fault.

This equipment is not suitable for use in locations where children are likely to be 

present.

Limited protection against accidental contact!

Receiver

Output 

1

Transmitter Tx1

 (input 1) corresponds to receiver output 

Transmitter Tx2 

(input 1) corresponds to receiver output 

Push button

Space 

to open cover

LED SYS

DIP-switch

Buzzer

visible through 

cover

2