1
ON
1 2
ON
1 2
XRF-R.1
50
121
23
5
50
121
23
5.7
4.2
4.2
22
106
LED 1
Single channel receiver to XRF wireless transmission system
Original operating instructions
Intended use: Monitoring safety edges and switches on industrial doors and gates
1
Safety instructions
ENGLISH
404169F
01/21
Receiver (Rx)
• Read these operating instructions thoroughly before putting the device into
operation and keep them for future reference.
• Do not use this product other than for its specified application.
• Only trained and qualified personnel may install and initialize the device.
• Only authorized factory personnel may perform hardware/software changes or
repairs to the product.
• Failure to follow these safety precautions may cause damage to sensor or objects,
serious personal injury, or death.
• It is the responsibility of the equipment manufacturer to carry out a risk assess-
ment and to install the system in compliance with applicable local, national and
international regulations, safety standards, codes and laws as well as the
Machinery Directive 2006/42/EC, should this apply.
• Always consider the safety functions of your applications as a whole, never just in
relation to one individual section of the system.
• The installer is responsible for testing the system to ensure it meets all applicable
safety standards.
• Safety devices that are classified as Category 2 according to EN ISO 13849-1 must
be tested regularly – at least once per cycle.
Receiver
Tx1
Tx2
• If the safety device is not requested operationally at least once a year, it must be
checked manually by the operator at least once a year.
• During the operation of electrical components
– e. g. in the case of a short circuit, hot and ionised gases can be emitted;
protection covers must not be removed!
• The sensor should only be operated from a safety extra low voltage (SELV) system
with safe electrical separation according to EN 61558. The wiring must be
protected against mechanical damage.
• Check the voltage data on the label of the switching device.
• Pay attention to all local relevant electrical safety regulations.
• Ensure that the device/installations cannot be switched on.
• Ensure that the power supply is disconnected.
• Protect the device with a housing against contamination or harsh environments.
• Disconnect device from mains in the event of a fault.
• After accessing the inside of the device, ensure the cover/protection seal is closed
tightly to achieve the designated protection rating.
Receiver
Output
1
Transmitter Tx1
(input 1) corresponds to receiver output
Transmitter Tx2
(input 1) corresponds to receiver output
Push button
Space
to open cover
LED SYS
DIP-switch
Buzzer
visible through
cover
2
Common application