41
Step 3:
Connect the High Level Sensor Assembly to the Hopper top (pre-drilled holes).
• Use a crescent wrench to remove the plastic plug on the side of the Hopper.
• Thread in the Low Level Sensor.
• Carefully connect the High and Low Level Sensor Cables to the end of each Sensor.
HIGH SENSOR
LOW SENSOR
Step 4:
Connect the High and Low level Sensor Cables to the bottom of the Conveyor Control.
• Ensure
HIGH SENSOR
(located on top of the inlet) is connected to the sensor connec-
tion on the bottom of the control box marked:
BIN HIGH SENSOR
.
• Connect
LOW SENSOR
(located on the side of the hopper) is connected to the sensor
connection on the bottom of the control box marked:
BIN LOW SENSOR
.
Continued
LOW Level Sensor
HIGH Level Sensor
Conveyor Control bottom