r

CT Injection System

CT Injection System

Operation Manual

Personalized Patient Protocol Technology (P3T)

P3T Pulmonary Angiography (PA) Module

for Certegra® Workstation

Содержание Certegra P3T PA

Страница 1: ...s t a l l a t i o n i n f o r m a t i o n m u s t b e s u p p l i e S e n u m b e r s CT Injection System CT Injection System Operation Manual Personalized Patient Protocol Technology P3T P3T Pulmonar...

Страница 2: ......

Страница 3: ...contact and to your local European competent authority or where applicable to the appropriate regulatory authority of the country in which the incident has occurred Hardware operating specifications...

Страница 4: ...Personalized Patient Protocol Technology P3T P3T Pulmonary Angiography PA Module ii...

Страница 5: ...3 5 4 P3T Preset Setup Options 4 7 4 1 Setup Options 4 7 4 2 Must Review Must Enter 4 11 4 3 DualFlow 4 12 5 Managing Presets 5 13 5 1 Create New Preset 5 13 5 2 Modify a Preset 5 15 5 3 Delete a Pre...

Страница 6: ...Personalized Patient Protocol Technology P3T P3T Pulmonary Angiography PA Module iv...

Страница 7: ...es individual contrast injection protocols and scan timing for individualized dosing P3T PA increases the consistency of individualized injection protocols amongst clinicians 1 3 Intended Use P3T PA i...

Страница 8: ...Personalized Patient Protocol Technology P3T P3T Pulmonary Angiography PA Module 1 2...

Страница 9: ...hat could result in minor or moderate injury to the patient or operator Read and understand the cautions before operating the injection system Indicates that the information is a notice Notices advise...

Страница 10: ...Personalized Patient Protocol Technology P3T P3T Pulmonary Angiography PA Module 2 4...

Страница 11: ...e contrast timing i e flow rate or injection duration Physicians must determine the contrast timing The overall injection protocol consists of two sub protocols an optional Pre Diagnostic Protocol and...

Страница 12: ...Personalized Patient Protocol Technology P3T P3T Pulmonary Angiography PA Module 3 6...

Страница 13: ...Test Inject Volume Sets the volume for the test injection when the Test Inject Delivery Method is set to Volume 10 mL 50 mL in increments of 1 mL 20 mL 6 Test Inject Duration Sets the duration of the...

Страница 14: ...for the first phase of the diagnostic protocol The Duration Adjustment is added to the Scan Duration to determine the injection duration of the first phase Contrast injection durations should be suff...

Страница 15: ...sh phase 0 mL 50 mL in increments of 1 mL 30 mL 16 Protocol Truncation Adjustment Sets the minimum time between when a phase containing contrast ends and when the scan ends Because of the time it take...

Страница 16: ...Method to use Weight Bins a representative weight within the selected range will be used to calculate the contrast dosage As a result the Key Pad weight entry method is more accurate compared to the W...

Страница 17: ...me the P3T Preset is used But there is no Required action Display The parameter will move towards the top of the list and be highlighted in beige X in Must Enter box Action User is Required to enter a...

Страница 18: ...time of injection of the DualFlow phase NOTE Since DualFlow is primarily beneficial for maintaining opacification of the right heart structures it may not be required for pulmonary angiography studies...

Страница 19: ...move presets from one folder to another How to create a copy of a preset Configuration of presets is typically done during initial set up and during injection protocol reviews It is recommended that t...

Страница 20: ...lues for the preset parameters 4 Select OK A preset entry screen displays 5 Select the Region to Save Press SAVE Figure 5 3 Preset Entry Screen 6 Modify a preset a Use the UP or DOWN arrows to scroll...

Страница 21: ...E The System highlights parameters marked as MUST ENTER when the user uses the preset and the user must provide a value to generate a protocol 7 In Select Region to Save select the folder in which to...

Страница 22: ...Modify the desired preset See step 6 in Create New Preset for more information 7 Store the Preset A user can save changes to an existing Preset save an existing preset with a new name or move a preset...

Страница 23: ...confirm the preset name and storage folder 5 3 Delete a Preset 1 From the launch menu select Setup P3T Preset Setup 2 Select Edit Existing Presets 3 Select the folder in which the Preset is stored 4...

Страница 24: ...lmonary Angiography PA Module 5 18 Figure 5 8 Delete Preset 5 4 Rearrange Preset Order 1 Select Setup Protocol Manager Setup 2 Select the desired folder 3 Select the protocol name 4 Select Move Up or...

Страница 25: ...jury or death may result Ensure that the programmed flow rate meets hospital guidelines Patient injury could result if P3T modules are used with patients with compromised renal function or other contr...

Страница 26: ...iew an alphabetical listing of all stored P3T presets 5 Select OK 6 Enter the values for the Must Enter parameters 7 Confirm the values for the Must Review parameters NOTE To view all of the parameter...

Страница 27: ...elect Cancel to exit Protocol Manager without generating a P3T Protocol 10 Select OK The Home screen displays the protocol generated based on the preset and user provided inputs The System is ready to...

Страница 28: ...essary to adjust the diagnostic protocol 4 Optionally select More Parameters to access additional editable parameters 5 Based on the above inputs P3T generates and displays an estimated Scan Delay Thi...

Страница 29: ...played Preset parameter for Minimum Injection Duration Figure 7 1 Select Minimum Injection Duration 6 Enter duration time using the keypad on the right 7 Select SAVE or Save As If selecting Save As a...

Страница 30: ...folder in which to store the preset 9 Select SAVE 10 Enter a name for the Preset and select Enter 11 Select Yes to confirm the Preset name and storage folder 7 3 Bolus Tracking 1 From the launch menu...

Страница 31: ...ect the folder in which to store the preset 9 Select SAVE 10 Enter a name for the Preset and select Enter 11 Select Yes to confirm the Preset name and storage folder 7 4 DualFlow Configuration 1 From...

Страница 32: ...Delivery Method 7 Optionally under MUST REVIEW and or MUST ENTER deselect the box es to remove the confirmation requirement 8 In Select Region to Save select the folder in which to store the preset 9...

Страница 33: ......

Страница 34: ...this publication at any time without prior notice or obligation Please contact your authorized representative from Bayer for the most current information All patient data that appear in this document...