Bayco Products, Inc. • 640 South Sanden Blvd. • Wylie, TX 75098 • USA • 1-800-233-2155 • 1-469-326-9400 • www.nightstick.com
INS-XPP-5466G2-19
02-22-2019
INSTALLING THE FORTEM ON TO THE HELMET
Image 4
Image 5
y
Choose the side of the helmet you wish to mount the light on.
y
Rotate the mount to orient the clamp with thumbscrew on top.
y
Open the clamp completely and fully seat over helmet brim, ensuring the clamp clears
any rubber helmet trim. (Image 4)
y
Tighten the clamp fi rmly with a fl at-blade screwdriver. (Image 5)
SCAN FOR
MOUNTING
INSTRUCTION
VIDEO
https://youtu.be/UPgCgUDOnH0
SETTING THE ANGLE OF THE LIGHT
y
Twist the light left or right on the vertical pivot until beam pattern is in an ideal position.
y
The tension on the mount is meant to be fi rm to maintain the aim.
y
Once aimed, the mount allows the user to position light above or below the brim by
rotating up or down as needed.
OPERATION
The FORTEM has seven lighting modes:
y
Constant-on high-brightness fl ashlight
y
Medium-brightness fl ashlight
y
Low-brightness fl ashlight
y
Constant-on high-brightness fl oodlight
y
Medium-brightness fl oodlight
y
Low-brightness fl oodlight
y
Constant-on Dual-Light mode
The FORTEM has two switches, the fl ashlight switch (closest to the front of the light)
and the fl oodlight switch (closest to the rear of the light) providing access to all modes.
CONSTANT-ON FLASHLIGHT
Press the fl ashlight switch (closest to the front of the light) until it clicks and then release
for constant-on fl ashlight in high-brightness mode. Press and release this same switch
again to turn the light off.
SELECT FLASHLIGHT BRIGHTNESS LEVEL
Press and hold down the fl ashlight switch. The fl ashlight will cycle from high to medium
to low and then back up again at a rate of approximately one mode per second. The light will
continue to cycle up and down through the various modes as long as the fl ashlight switch
is held down. When the desired brightness level is reached, simply release the fl ashlight
switch, and the light will remain in that brightness mode. Pressing and holding the fl ashlight
switch again will cause the light to cycle from whatever mode it is currently in. Press and
release the fl ashlight switch to turn the light off.
CONSTANT-ON FLOODLIGHT
Press the fl oodlight switch (closest to the rear of the light) until it clicks and then release
for constant-on fl oodlight in high-brightness mode. Press and release this same switch
again to turn the light off.
Instruction Manual
FORTEM™ XPP-5466
US PATENT 9,713,217
THE XPP-5466 IS APPROVED FOR USE
CLASS I DIV 1 GRPS A-D T4
CLASS II & III DIV 1 GRPS E-G T135°C
CLASS I ZONE 0 AEx ia IIC T4 Ga
CLASS I ZONE 0 Ex ia IIC T4
-20ºC ≤ Tamb ≤ +40ºC
3.0V/Cell / Energizer 123
0359
E 467756
INTRINSICALLY SAFE
SECURITE INTRINSEQUE
Conforms to:
ANSI/UL STD 913, ANSI/UL 60079-0
Certified to:
CAN/CSA STD C22.2 No 157
CAN/CSA STD C22.2 No 60079-0
CAN/CSA STD C22.2 No 60079-11
CSA STD C22.2 No 25
Bayco Products, Inc. XPP-5466
WARNINGS:
Do not change batteries in hazardous location.
Use only Energizer 123 Batteries
ID 4001184
WARNINGS - INTRINSICALLY SAFE
y
Warning: Use only the approved non-rechargeable batteries listed below.
y
Warning: Do NOT attempt to use rechargeable CR123A batteries with this light.
y
Warning: To prevent ignition of a hazardous atmosphere, do not open the battery
compartment in the hazardous environment. This task must ONLY be performed in an
area known to be non-hazardous.
y
Warning: When exchanging batteries, use only ENERGIZER CR123A BATTERIES.
y
Warning: To prevent ignition of a hazardous atmosphere, the CR123A batteries must
only be exchanged in an area known to be non-hazardous.
y
Warning: To reduce the risk of explosion, do not mix new non-rechargeable batteries
with used non-rechargeable batteries, or mix non-rechargeable batteries from different
manufacturers.
y
Warning: Substitution of components may impair intrinsic safety.
STROBE WARNING
Exposure to strobing lights may cause dizziness, disorientation, and nausea. A very
small percentage of people suffer from photosensitive epilepsy and may experience
seizures or blackouts triggered by strobing lights. For more information from the EPILEPSY
FOUNDATION about photosensitivity and seizures, please visit
www.epilepsy.com
.
Anyone who has had symptoms linked to this condition should consult a doctor before
using this product.
SPECIAL INSTRUCTIONS FOR INTRINSIC SAFETY
For personal safety, always confi rm the rating of any known hazardous or potentially
hazardous location where the light is to be used.
INSTALLING BATTERIES INTO THE FORTEM
Image 1
Image 2
Image 3
y
To install the included CR123A Lithium Batteries in the FORTEM, begin by unscrewing
the screw on the battery compartment door. (Image 1)
y
Insert both batteries into the battery compartment paying attention to the battery
orientation marked on the back of the battery compartment door. (Image 2)
y
Re-install the battery compartment screw by pressing the door fully closed and then
tightening the screw until it is hand tight. CAUTION: Do not cross-tread or strip the screw
threads. (Image 3)
y
Test the operation of the light (see OPERATION below).