background image

 

Part No. 117236-B Rev. 00
March 1998

 
 
 
  

Nautica 200 
Installation Guide

Содержание Nautica 200

Страница 1: ...Part No 117236 B Rev 00 March 1998 Nautica 200 Installation Guide ...

Страница 2: ...e information in this document is proprietary to Bay Networks Inc Trademarks Bay Networks and Nautica are registered trademarks and BCC and the Bay Networks logo are trademarks of Bay Networks Inc Microsoft Windows and Windows NT are registered trademarks of Microsoft Corporation All other trademarks and registered trademarks are the property of their respective owners Statement of Conditions In t...

Страница 3: ...can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced rad...

Страница 4: ...ry Control Council for Interference VCCI Statement Voluntary Control Council for Interference VCCI Statement This is a Class B product based on the standard of the Voluntary Control Council for Interference from Information Technology Equipment VCCI If this is used near a radio or television receiver in a domestic environment it may cause radio interference Install and use the equipment according ...

Страница 5: ...ay not prevent the degradation of service in some situations Repairs to certified equipment should be made by a representative designated by the supplier Any repairs or alterations made by the user to this equipment or equipment malfunctions may give the telecommunications company cause to request the user to disconnect the equipment Users should ensure for their own protection that the electrical...

Страница 6: ...vis Veuillez prendre note que pour tout appareillage supportant des lignes de type loopstart vous pouvez utiliser le Ringer Equivalence Number REN attribué à chaque terminal pour déterminer le nombre maximal de terminaux qui peuvent être branchés à votre interface de téléphones Le raccordement à l interface pourra se composer de toute combinaison de terminaux pour autant que la somme des RENs ne d...

Страница 7: ...facilities equipment operations or procedures that could affect the proper functioning of your equipment The telephone company will notify you in advance of such changes to give you an opportunity to maintain uninterrupted telephone service 3 If the unit causes harm to the telephone network the telephone company may temporarily discontinue your service If possible they will notify you in advance b...

Страница 8: ...n all title and ownership in both the Software and user manuals including any revisions made by Bay Networks or its licensors The copyright notice must be reproduced and included with any copy of any portion of the Software or user manuals Licensee may not modify translate decompile disassemble use for any competitive analysis reverse engineer distribute or create derivative works from the Softwar...

Страница 9: ...Y OR FITNESS FOR A PARTICULAR PURPOSE Licensee is responsible for the security of its own data and information and for maintaining adequate procedures apart from the Software to reconstruct lost or altered files data or programs 4 Limitation of liability IN NO EVENT WILL BAY NETWORKS OR ITS LICENSORS BE LIABLE FOR ANY COST OF SUBSTITUTE PROCUREMENT SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMA...

Страница 10: ...Without limiting the foregoing Licensee on behalf of itself and its subsidiaries and affiliates agrees that it will not without first obtaining all export licenses and approvals required by the U S Government i export re export transfer or divert any such Software or technical data or any direct product thereof to any country to which such exports or re exports are restricted or embargoed under Un...

Страница 11: ...Installation Assistant by loading the setup software on the accompanying CD see page 8 Nautica Wizard a Microsoft Windows 95 Windows NT application is used to perform configuration tasks Experienced network users can troubleshoot the Nautica 200 using a command line interface which is available via Telnet or HyperTerminal see step 5 on page 7 This guide contains the following sections Checklist pa...

Страница 12: ...autica 200 package includes the following items The Nautica 200 router One power supply unit PSU of the correct voltage rating See Table 1 One ISDN cable black labelled 119071 A or one ISDN cable red labelled 117238 One Installation CD One Manager cable labelled 117239 One Ethernet Local Area Network LAN cable gray labelled 118314 One RJ 45 to RJ 11 ISDN cable labelled 119068 A U S only Two Britis...

Страница 13: ...e Table 1 Table 1 lists the operating requirements for correct installation of the Nautica 200 Table 1 Operating Requirements Parameter Specification Power supply Europe 220 to 240 VAC 50 Hz nominal Power supply North America 110 VAC 60 Hz Power supply current 41 mA 240 VAC 90 mA 110 VAC Power consumption 10 W nominal Operating temperature 10o to 40oC 50o to 104oF Humidity 5 to 95 nonconducting LA...

Страница 14: ...you to monitor the activity on your router The green LED will flash continuously when the router is in use If this happens when you are not actively using your PC then the PC or an application on the PC is connecting to a remote network resource If you are in any doubt at all about any of the following points or the operation of your router contact your local ISDN supplier for advice The remainder...

Страница 15: ...ider Ensure that you have the local directory numbers assigned to the line by your ISDN service provider Ensure that you have the Service Profile Identifiers SPIDs for the local directory numbers also assigned by your ISDN service provider Hardware Installation This section describes the physical installation of the Nautica 200 For safety follow all of the steps in the order presented Connecting t...

Страница 16: ...6 117236 B Rev 00 Nautica 200 Installation Guide Figure 1 Nautica 200 Cabling Options All countries except Australia Figure 2 Nautica 200 Cabling Options Australia ...

Страница 17: ...onnect one telephony device telephone facsimile or modem to each telephone port If you are in the UK you must use the telephone adapters supplied with your Nautica 200 In other countries you may need to supply your own telephone adapters 4 Connect the power cable to the port labelled 9v DC The Nautica 200 has no on off switch it turns on immediately when you plug the power adapter into the power o...

Страница 18: ...d the Nautica 200 has powered up load the Nautica 200 configuration software onto your PC 1 Insert the CD that came with the Nautica 200 package into your CD ROM drive 2 If auto start is enabled on your PC the setup program starts automatically 3 If the setup program does not start automatically launch Windows Explorer change to the CD ROM drive then double click on the program icon called setup e...

Страница 19: ...ighlights operational features that you need to be aware of before using the Nautica 200 Setting up e mail Most TCP IP based e mail clients can be configured to check the mail server for new mail at set intervals This is known as polling Note The Nautica Configuration Wizard CD auto run feature causes the installation software to run every time the CD is inserted If you do not want to re install t...

Страница 20: ...4 calls every day even if you have no new e mail Remotely Mapped Drives In most popular PC operating systems it is possible to map virtual drives such as J to file servers on the network If you map network drives over a remote ISDN connection problems can occur Every time you open a file or move into a new folder it is likely that the PC may request the current status of all drives and bring up an...

Страница 21: ... Click on OK in the Networks window 8 Close the Control Panel 9 It may be necessary to reboot your PC at this time Graphical FTP Using Keep Alive Traditionally FTP servers time out or end an FTP session if there is no activity after a few minutes Most command line FTP clients take no steps to avoid this timeout Some of the new graphical FTP clients however make frequent read or keepalive requests ...

Страница 22: ... PC in order to update sound and graphic files continuously Using a remote router such sites will keep your ISDN connection open Other Web sites cause your browser to refresh the screen at regular intervals for example every 30 seconds Again this can cause a link to stay open In order to minimize the effect of these data streams do not leave your PC unattended when you have a Web site oen and clos...

Отзывы: