2. Install the heat pump's indoor module on a solid, stable structure
capable of bearing the weight of the heat pump when full of water and
fitted with its various accessories.
3. Install the indoor module as close as possible to the draw-off points in
order to minimise energy losses through the pipes.
5.5.2
Allowing sufficient space for the indoor module
Allow sufficient space around the heat pump indoor module to ensure
adequate access and facilitate maintenance.
Important
The ceiling height must be at least 2.20 m. If the space between
the ceiling and the top of the product is less than 250 mm, it will
not be possible to remove the anode for maintenance operations.
In this case, replace the magnesium anode with the impressed
current anode option (package EH921) before positioning the
product.
5.5.3
Install the indoor module in a cupboard
The indoor module can be installed in a cupboard.
Observe the overall dimensions (including hinges) of 564 x 580 mm.
5.5.4
Removing the appliance's front panel
During installation and for easier handling of the appliance, remove the
front panel of the indoor module.