Installation, Commissioning, Service & Repair

1. This appliance must be install in accordance with the
manufacturer’s instructions and the regulations in force. Read
the instructions fully before installing or using the appliance.

2. In GB, this must be carried out by a competent person as
stated in the Gas Safety (Installation & Use) Regulations.

3. 

Definition of competence:

A person who works for a Gas

Safe registered company and holding current certificates in the
relevant ACS modules, is deemed competent.

4. In IE (Eire), this must be carried out by a competent person
as stated in I.S. 813 “Domestic Gas Installations”.

All Gas Safe registered engineers carry an ID card with their
licence number and a photograph. You can check your
engineer is registered by telephoning 0800 408 5500 or online
at www,gassaferegister.co.uk

The boiler meets the requirements of Statutory Instrument
“The Boiler (Efficiency) Regulations 1993 No 3083” and is
deemed to meet the requirements of Directive 92/42/EEC on
the energy efficiency requirements for new hot water boilers
fired with liquid or gaseous fuels:-

Type test for purpose of Regulation 5 certified by:
Notified Body 0087.

Product/Production certified by:
Notified Bodies 0086.

For GB/IE only.

6.2 

Benchmark Commissioning Checklist

1. Please ensure that the installer has fully completed the
Benchmark Checklist on the inside back pages of the
installation instructions supplied with the product and that you
have signed it to say that you have received a full and clear
explanation of its operation. The installer is legally required to
complete a commissioning checklist as a means of complying
with the appropriate Building Regulations (England and Wales).

2. All installations must be notified to Local Area Building
Control either directly or through a Competent Persons
Scheme. A Building Regulations Compliance Certificate will
then be issued to the customer who should, on receipt, write
the Notification Number on the Benchmark Checklist.

3. This product should be serviced regularly to optimise its
safety, efficiency and performance. The service engineer should
complete the relevant Service Record on the Benchmark
Checklist after each service.

4. The Benchmark Checklist may be required in the event of
any warranty work.

Содержание Main System 24 Eco Elite

Страница 1: ...Baxi Heating UK Ltd 2013 User s Guide and Important Warranty Information System Eco Elite Range Please keep these instructions in a safe place If you move house please hand them over to the next occupier ...

Страница 2: ...rooks House Coventry Road Warwick CV34 4LL Full acknowledgement of author and source must be given WARNING Any person who does any unauthorised act in relation to a copyright work may be liable to criminal prosecution and civil claims for damages 1 0 Quick Reference Guide 3 2 0 Troubleshooting 4 3 0 Repressurising System 6 4 0 Clearances 7 5 0 Care of the Boiler 8 6 0 Legislation 9 7 0 Notes 10 8 ...

Страница 3: ...ator will illuminate when the boiler is in the central heating mode Burner On Indicator The indicator will illuminate when the burner has fired and is heating your central heating or domestic hot water Boiler Output Temperature In either the central heating or domestic hot water position the display will illuminate showing the current boiler temperature in degrees centigrade Central Heating System...

Страница 4: ...switched on Reset Is the display lit Display Central Heating Indicator Burner On Indicator Boiler operating satisfactorily bar 0 1 2 3 4 Is the Central Heating System Pressure between 1 and 2 5 bar If the reading falls below 1 bar repressurise the system as described in section 3 1 Does the display show an error code e g E133 E110 Boiler not working NO NO YES YES YES NO Turn the ON OFF Reset Selec...

Страница 5: ...fitted set high enough 15 10 5 20 2 5 15 10 5 20 2 5 Turn Room Thermostat to maximum setting typical example shown If you don t know what you need to do to get the boiler to light or need help with the system and controls contact your installer as soon as possible YES NO CONTACTYOUR INSTALLER OR SERVICE ENGINEER YES 12 1 2 3 4 5 6 7 8 9 1 0 11 CH ON CH OFF Typical examples of external timer NO ...

Страница 6: ...u are unsure of its position or cannot identify it consult the installer who fitted the boiler 4 The filling loop consists of two taps and a separate copper pipe with connection fittings 5 Only when repressurising should the copper pipe be connected between the two taps Ensure that the nuts on the pipe ends are tightened onto the taps 6 Fully open one of the taps first and then while watching the ...

Страница 7: ...inimum clearances for Safety and Maintenance Figs 3 4 Top 200mm 300mm for 80 125mm flueing system Bottom 200mm Left side 5mm Right Side 5mm Front 5mm In Operation 450mm For Servicing 7 If your boiler is installed in a compartment do not use it for storage purposes Do not obstruct any purpose provided ventilation openings 8 Flammable materials must not be stored in close proximity to your boiler 9 ...

Страница 8: ... with 33 E50 is shown as E then 50 3 E20 E28 E50 E160 indicate faulty components You should make a note of the displayed error code and contact your installer or service engineer 4 If E110 is displayed overheat of the primary water or flue system has occurred Turn the selector switch to the reset position and hold for at least 5 seconds If the boiler does not relight or the code is displayed regul...

Страница 9: ...ciency requirements for new hot water boilers fired with liquid or gaseous fuels Type test for purpose of Regulation 5 certified by Notified Body 0087 Product Production certified by Notified Bodies 0086 For GB IE only 6 2 Benchmark Commissioning Checklist 1 Please ensure that the installer has fully completed the Benchmark Checklist on the inside back pages of the installation instructions suppli...

Страница 10: ...7 0 Notes 10 Baxi Heating UK Ltd 2013 ...

Страница 11: ...ning their taps to the right towards the wall Fig 6 3 Call your Installer or Service Engineer as soon as possible If you smell gas Do not operate light switches Do not operate any electrical equipment Do not use a telephone in the hazardous area Extinguish any naked flame and do not smoke Open windows and doors in the hazardous area Turn off the gas supply at the meter Warn any other occupants and...

Страница 12: ...and Bank Holidays 8 30am 2pm excluding Christmas Day and New Years Day When calling heateam it would be helpful if you could have the following information to hand 1 Boiler serial number see opposite 2 Boiler make and model number 3 Your installer name and address details 4 Proof of purchase if you do not have the boiler serial number What this warranty covers Free of charge repair or replacement ...