5.0 Care of the Boiler

8

© Baxi Heating UK Ltd 2013

5.1

Cleaning the Outer case

The painted panels should be wiped with a damp cloth and
then dried completely. 

DO NOT USE ABRASIVE

CLEANING AGENTS.

5.2

Protection & Precaution

1. The boiler incorporates an integral frost protection feature
that will operate in both modes. If the boiler temperature falls
below 5° C, then the boiler will operate until the water
temperature has been raised.

2. If a system frost thermostat has been fitted (your installer
will be able to advise you), then to operate correctly and
protect your system, the gas and electricity must be left on and
the appliance set in the central heating mode.

3. The boiler incorporates an integral pump protection feature
which continually monitors the time since the pump last
operated. To prevent seizure, the pump will operate for
approximately 1 minute if it has not run in the last 24 hours.

5.3

Fault Indication

1. If a fault occurs on the boiler an error code may be shown
on the facia display.

2. The codes are either two or three digit, preceded by the
letter 'E'. For example, code E133 will be displayed by 'E1'
alternating with '33'. E50 is shown as 'E' then '50'.

3. E20, E28, E50 & E160 indicate faulty components. You
should make a note of the displayed error code and contact
your installer or service engineer.

4. If E110 is displayed overheat of the primary water or flue
system has occurred. Turn the selector switch to the reset
position and hold for at least 5 seconds. If the boiler does not
relight, or the code is displayed regularly contact your installer
or service engineer.

5. E119 is displayed when the primary water pressure is less
than 0.5 bar. After repressurising the system the boiler should
operate. Your installer will be able to advise you about the
method of repressurising. See page 6 for further details. 

6. E133 indicates that the gas supply has been interrupted,
ignition has failed or the flame has not been detected. Ensure
that the gas supply has not been turned off, and turn the
selector switch to the reset position and hold for at least 5
seconds. If the boiler does not relight, or the code is displayed
regularly contact your installer or service engineer.

 Central Heating NTC Fault
PCB Fault
Hot Water NTC Fault 
Safety Thermostat Operated
Water Pressure Switch Not Operated
Interruption Of Gas Supply or Flame Failure
Fan or Fan Wiring Fault

E20
E28
E50
E110
E119
E133
E160

Table of Error Codes

Reset

bar

0

1

2

3

4

Display

Then

Fig. 5

Содержание Main System 24 Eco Elite

Страница 1: ...Baxi Heating UK Ltd 2013 User s Guide and Important Warranty Information System Eco Elite Range Please keep these instructions in a safe place If you move house please hand them over to the next occupier ...

Страница 2: ...rooks House Coventry Road Warwick CV34 4LL Full acknowledgement of author and source must be given WARNING Any person who does any unauthorised act in relation to a copyright work may be liable to criminal prosecution and civil claims for damages 1 0 Quick Reference Guide 3 2 0 Troubleshooting 4 3 0 Repressurising System 6 4 0 Clearances 7 5 0 Care of the Boiler 8 6 0 Legislation 9 7 0 Notes 10 8 ...

Страница 3: ...ator will illuminate when the boiler is in the central heating mode Burner On Indicator The indicator will illuminate when the burner has fired and is heating your central heating or domestic hot water Boiler Output Temperature In either the central heating or domestic hot water position the display will illuminate showing the current boiler temperature in degrees centigrade Central Heating System...

Страница 4: ...switched on Reset Is the display lit Display Central Heating Indicator Burner On Indicator Boiler operating satisfactorily bar 0 1 2 3 4 Is the Central Heating System Pressure between 1 and 2 5 bar If the reading falls below 1 bar repressurise the system as described in section 3 1 Does the display show an error code e g E133 E110 Boiler not working NO NO YES YES YES NO Turn the ON OFF Reset Selec...

Страница 5: ...fitted set high enough 15 10 5 20 2 5 15 10 5 20 2 5 Turn Room Thermostat to maximum setting typical example shown If you don t know what you need to do to get the boiler to light or need help with the system and controls contact your installer as soon as possible YES NO CONTACTYOUR INSTALLER OR SERVICE ENGINEER YES 12 1 2 3 4 5 6 7 8 9 1 0 11 CH ON CH OFF Typical examples of external timer NO ...

Страница 6: ...u are unsure of its position or cannot identify it consult the installer who fitted the boiler 4 The filling loop consists of two taps and a separate copper pipe with connection fittings 5 Only when repressurising should the copper pipe be connected between the two taps Ensure that the nuts on the pipe ends are tightened onto the taps 6 Fully open one of the taps first and then while watching the ...

Страница 7: ...inimum clearances for Safety and Maintenance Figs 3 4 Top 200mm 300mm for 80 125mm flueing system Bottom 200mm Left side 5mm Right Side 5mm Front 5mm In Operation 450mm For Servicing 7 If your boiler is installed in a compartment do not use it for storage purposes Do not obstruct any purpose provided ventilation openings 8 Flammable materials must not be stored in close proximity to your boiler 9 ...

Страница 8: ... with 33 E50 is shown as E then 50 3 E20 E28 E50 E160 indicate faulty components You should make a note of the displayed error code and contact your installer or service engineer 4 If E110 is displayed overheat of the primary water or flue system has occurred Turn the selector switch to the reset position and hold for at least 5 seconds If the boiler does not relight or the code is displayed regul...

Страница 9: ...ciency requirements for new hot water boilers fired with liquid or gaseous fuels Type test for purpose of Regulation 5 certified by Notified Body 0087 Product Production certified by Notified Bodies 0086 For GB IE only 6 2 Benchmark Commissioning Checklist 1 Please ensure that the installer has fully completed the Benchmark Checklist on the inside back pages of the installation instructions suppli...

Страница 10: ...7 0 Notes 10 Baxi Heating UK Ltd 2013 ...

Страница 11: ...ning their taps to the right towards the wall Fig 6 3 Call your Installer or Service Engineer as soon as possible If you smell gas Do not operate light switches Do not operate any electrical equipment Do not use a telephone in the hazardous area Extinguish any naked flame and do not smoke Open windows and doors in the hazardous area Turn off the gas supply at the meter Warn any other occupants and...

Страница 12: ...and Bank Holidays 8 30am 2pm excluding Christmas Day and New Years Day When calling heateam it would be helpful if you could have the following information to hand 1 Boiler serial number see opposite 2 Boiler make and model number 3 Your installer name and address details 4 Proof of purchase if you do not have the boiler serial number What this warranty covers Free of charge repair or replacement ...

Отзывы: