9
0510_2701
Figure 4.1
Fault warnings appear on the secondary display (figure 1
b
) alternating with the time, both of them
flashing (figure 4.1). It is not possible to reset malfunction warnings which appear on the secondary
display as the cause of the alarm has first to be removed.
All the faults are displayed in order of importance; if several faults occur simultaneously, the first to
be displayed is the one with highest priority. After the cause of the first fault has been removed, the
second one will be displayed, and so on.
If any given fault occurs frequently, contact the authorised Service Centre.
action required
call the authorised service centre.
call the authorised service centre.
call the authorised service centre.
press the reset key (for about 2 seconds: if this device is triggered
repeatedly, call the authorised service centre)
call the authorised service centre.
call the authorised service centre.
call the authorised service centre.
press the reset key (for about 2 seconds); if the fault persists, call the
authorised service centre)
switch off the electricity supply to the boiler for 10 seconds; if the fault
persists, call the authorised service centre)
press the key again (about 2 seconds)
Press and hold reset button (2 seconds approx.) then press again when
warning E153 appears
call the authorised service centre.
check that the system is at the rated pressure. (refer to the section on filling
the system). if the fault persists, call the authorised service centre.
Fault description
outdoor temperature probe sensor failure
ntc output sensor failure
domestic hot water ntc sensor failure
safety or flue gas thermostat tripped
loss of flame during operation (the ionization
current has fallen below the limit)
minimum fan speed limit is hurt
floor thermostat tripped
no gas
boiler circuit board error
the reset key has been pressed
inappropriately
internal error on boiler circuit module
fan speed threshold not reached
no hydraulic differential pressure
switch enabling signal
3-9. Fault warnings table
Fault
code
E10
E20
E50
E110
E128
E129
E132
E133
E151
E153
E154
E160
E164