9 Settings
59
Setting
(read only)
Description
Value
AM016
Flow temperature
°C
AM018
Return temperature
°C
AM019
Actual water pressure in central heating system
bar
AM024
Current output of the boiler
0/100%
AM027
Outside temperature
°C
AM036
Flue gas temperature
°C
AM037
Status of the 3-way valve (0: Heating, 1: DHW)
0/1
AM040
Outgoing DHW temperature check
°C
AM091
Season mode (0: winter, 3: summer)
0/3
AM101
Internal set point
°C
BM000
DHW temperature
°C
CM030
Current room temperature for zone
°C
CM120
Current operating mode in the zone (0: Disabled, 1: Enabled)
0/1
CM190
Zone ambient set point
°C
CM210
Outside temperature in the zone
°C
CM280
Zone calculated set point
°C
DM001
Temperature of the DHW tank
°C
DM002
Outgoing DHW flow speed
l/min
DM005
Solar system DHW temperature
°C
DM009
Primary operating mode (0: Programming, 1: Manual, 2: Antifreeze/Holiday)
0/1/2
DM019
DHW mode active (1: Comfort, 2: Low, 3: Holiday, 4: Antifreeze
1/2/3/4
DM029
DHW temperature set point
°C
GM001
Actual fan RPM
rpm
GM002
Actual fan RPM setpoint
rpm
GM003
Flame detected (0: Not detected, 1: Detected)
0/1
GM004
Gas valve (0: Open, 1: Closed, 2: Off)
0/1/2
GM007
Start-up (0: Off, 1: On)
0/1
GM008
Actual flame current measured
μA
GM012
Contact release signal X16 (0: No; 1: Yes)
0/1
GM013
Boiler shutdown signal input (0: Open, 1: Closed)
0/1
GM044
Reason for shutdown checked (0: None)
1. Heating Stoppage
2. DHW Stoppage
3. Awaiting burner ignition
4. Heating flow temperature above maximum value
5. Heating flow temperature above the starting value
6. Heat exchanger temperature above the starting value
7. Average heating flow temperature value above the starting value
8. Heating flow temperature above the setpoint value
9. Temperature difference between flow and return too great
10. Heating flow temperature above the shutdown value
11. Heat request before the minimum wait time between two consecutive requests
12. Shutdown caused by flame value being too low
13. Solar temperature above the shutdown value
0/13
9.4.1
Statuses and sub-statuses
The STATUS is the operating phase of the boiler at the moment
of display. To view the status, select the parameter AM012. The
SUB-STATUS is the instantaneous operation the boiler is
performing at the moment of display. To view the sub-status,
select the parameter AM014.
Combi 2