background image

en

United Kingdom

These instructions are to be left with the user. 

The Assure Vertical SHRU should only be installed by a competent 

plumber who has the expertise to be guided by this manual.

Please read the entire manual before commencing the installation process.

Assure Vertical SHRU

Installation & Maintenance Manual

Waste Water Heat Recovery Unit

Содержание Assure Vertical SHRU

Страница 1: ...sure Vertical SHRU should only be installed by a competent plumber who has the expertise to be guided by this manual Please read the entire manual before commencing the installation process Assure Vertical SHRU Installation Maintenance Manual Waste Water Heat Recovery Unit ...

Страница 2: ...2 Vert SHRU Contents Section Page 1 0 Introduction 3 2 0 Technical Data 4 3 0 Installation Preparation 5 4 0 Installation 8 5 0 Maintenance 10 6 0 Warranty 10 ...

Страница 3: ... with in conjunction with a system design checklist and an installation checklist and certificate of installation supplied with this document and available at www ncm pcdb org uk sap 4 The system should be installed by a suitably qualified plumber with system design consideration being equally important to a correct installation For recognition of the Assure SHRU within SAP a system design checkli...

Страница 4: ... 8 6 110 mm 5 Baxi Assure SHRU Installation SAP Label 1 Product Body 2 Tee Piece 45 3 Cap Cleaning Access Ø50 4 45 Elbow Ø50 2 off 5 Adaptor Ø50 to Ø43 2 off 6 Reducer Male 3 4 to Female 1 2 inc cap 2 off 7 90 Elbow Female Ø50 Female Ø50 8 Mounting Bracket 2 off 9 Installation Maintenance Manual 10 SAP Label In addition it is strongly recommended to obtain two suitable isolation valves to be insta...

Страница 5: ...er supply to the shower mixer valve is pre heated System B configuration or the pre heated mains water from the unit is only connected to the combination boiler or hot water cylinder System C configuration the efficiency of the SHRU will decrease by at least 15 System A Fig 2 SHRU outlet connects to water heater inlet AND shower cold inlet System B Fig 3 SHRU outlet connects to shower cold inlet O...

Страница 6: ...RU installed the cold water inlet temperature will increase slowly because it will be warmed from the heat transferred from the waste water via the SHRU heat exchanger 2 If a non thermostatically controlled showerhead is fitted continued adjustment of the valve will be required to avoid hotter water temperatures from the shower Therefore it is required that a thermostatically controlled showerhead...

Страница 7: ...r C configuration been selected 8 Is the plumbing design configured in order to prevent connection of hot water take off points such as taps from the SHRU preheated water outlet 9 Is an installation location specified for the SHRU that does not normally exceed 25 C 10 Can the SHRU be installed within a tolerance of 20mm of vertical 11 If shut off valves are specified for SHRU inlet and or outlet a...

Страница 8: ...g the two holes It is not necessary to plug a wooden structure Fig 7 3 Fit the fixing clamps to the wall and mount the SHRU body in them with the waste water discharge at the bottom Ensure the body is vertical in all planes Fig 8 tighten the clamps 4 Take the 45 fork and determine the correct orientation Fig 9 then using a suitable adhesive fix it in place 5 Fit the 45 waste water inlet connectors...

Страница 9: ...50 to Ø43 adaptor connect the waste water outlet to the waste system of the property Fig 12 7 Connect the pre heated cold outlet Fig 13 mains cold water inlet Fig 14 pipework It is strongly recommended that this pipework incorporates suitable isolation valves as shown Fig 12 Fig 13 Fig 14 ...

Страница 10: ...on for leaks etc 6 0 Warranty 1 The Assure Vertical SHRU warranty is valid for 2 years after installation date 2 During the warranty period if the product has a defect in design material or workmanship it must be returned to the place of purchase 3 The warranty will be invalidated if product failures are caused by the following Installed with cold inlet pressure above 10 bar Use of the system with...

Страница 11: ...Vert SHRU 11 ...

Страница 12: ...scriptions and illustrations provided in this document have been carefully prepared but we reserve the right to make changes and improvements in our products which may affect the accuracy of the information contained in this leaflet All goods are sold subject to our standard Conditions of Sale which are available on request ...

Отзывы: