Annex B: Electrically controlled wiring diagram
3-phase 12/16kW
&$3
&1
&1
&1
&1
&1
&1
,&
&1
&1
',6
&1
&1
5
5
&$3
&1
&1
*1'B
&1
&1
&1
/¶
/¶
/¶
&1
&1
&1
&1
&1
&1
&1
&1
*1'B
POWER & FIL
TER
BOARD
MAIN CONTROL
BOARD
89
:
&1
&1
3
11B
&1
IPM MODULE
=5
IC201
&1
&1
1
&1
/
&1
/
&1
/
7UDQVIRUPHU
Note
Threading direction
Note
Threading direction
I+
NOTE
External load current is needed less than 0.5A, if the load current is greater than 0.5A,the load must be controlled through
AC contactor
. Each external load current is needed less than 0.5A
Equipment must be grounded.
All high-voltage external load, if it is metal or a grounded port, must be grounded.
"AHS1" "AHS2", "A1" "A2", "R1" "R1" and "DTF1" "DTF2" wiring terminal ports provide only the switch signal.
&1
&203
.
U
V
W
0*
+352
%%%3
=
67)
69
+($
7
&1
69
&1
TRANS OUT
&1
TRANS IN
&1
ON/OFF
&1
&1
FS
&1
&1
POWER
&1
POWER
&1
&1
&1
'()5267
PRO_HYD
6
6
&1
SOLAR SIGNAL
&1
PUMP_I
&1
&1
&1
&1
ROOM
THERMOST
AT
;
&1
TBH_FB
IBH2
&1
IBH1
TBH
&1
IBH1/ 2_FB
HEA
T
P_S
ALARM
P_
R
P_
G
P_
F
SV2
SV1
SV3
RUN
AHS
;7
;7
;7
&1
&1
&1
&1
&1
A
BX
Y
E
P
Q
E
M1
M2
SL1
SL2
C
TBH
N
1ON
1OFF
P_o
N
HT
N
3ON
H
L1
N
P_c
N
Sv2
N
IBH1
N
P_s
N
3OFF
&1
R1
R2
AHS1
AHS2
P_d
N
DTF1
DTF2
&1
&1
12
3
4
5
67
8
9
10
1
23
4
5
6
7
89
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
30
31
32
29
;7
(
<
3
(
4
HY
DR
O-
BO
X C
ON
TR
OL
B
OA
RD
PUMP_i
&1
75$16
&1
7
7%
7:LQ
7:RXW
&1
&1
$
$
$
REACT
OR
REACT
OR
REACT
OR
REACTOR
&$3
&$3
&$3
R4
R5
R3
XT1
05
OUTDOOR UNIT POWER SUPPL
Y
37&
37&
T
T
;7
;7
$
$
$
$
$
$
&1
&1
&1
&1
7
7
;3
;6
;3
;6
7
+35(6
7
&1
L-PRO
XS6
XP6
XS5
XP5
&1
((9
)$1'2:1
)$183
6:
ON
32
1
6:
ON
2
1
05
05
.0
.0
&7
L
ea
ka
ge P
ro
te
ct
io
n S
w
itc
h
m
us
t b
e i
ns
ta
lle
d t
o t
he p
ow
er
su
pp
ly
o
f t
he
u
ni
t.
Equipment must be grounded.
EL
EC
TRI
CH
EA
TIN
G
PO
WE
R
SU
PP
LY
&7
05
(;B7
;7
)6B7
(9B7
TCO
ATCO
L2
2
L2
1
N1
2
N1
1
1 3 5 21
2 4 6 22
KM1
XT5
,%+
,%
+
,%
+
I>
I>
CB
I>
L1
L2
L3
KM4
1 3 5 21
2 4 6 22
L1
L2
L3
XT1
1
LP
S
AB
C
7%
7
7
6
',6
',3
21
',3
21
05
L
ea
ka
ge P
ro
te
ct
io
n S
w
itc
h
m
us
t b
e i
ns
ta
lle
d t
o t
he
p
ow
er
s
up
pl
y o
f t
he
e
le
ct
ri
c h
ea
tin
g.
Equipment must be grounded.
&1
7D
6*(98
&1
+7&20&/
&1
5220
7+(50267$7
/2:92/7$*(
60$57
*5,'
/2:92/7$*(
&1
&1
N
L3
L2
L1
FUSE
LPS
L1
L2
L3
N
BACKUP HEATER(OPTIONAL)
05
05
05
05
05
Содержание Assure Mono 12
Страница 4: ...This product is a MCS register product under BAXI brand ...