background image

© Baxi Heating UK Ltd 2009

Ambiflo

TM 

Heat Pump System

7kW to 10.5kW Inclusive

Air to Water Heat Pump 

for

Outdoor Installation

User’s Operating Instructions

Содержание Ambiflo

Страница 1: ... Baxi Heating UK Ltd 2009 AmbifloTM Heat Pump System 7kW to 10 5kW Inclusive Air to Water Heat Pump for Outdoor Installation User s Operating Instructions ...

Страница 2: ...ps Baxi Heating UK Ltd 2009 All rights reserved No part of this publication may be reproduced or transmitted in any form or by any means or stored in any retrieval system of any nature including in any database in each case whether electronic mechanical recording or otherwise without the prior written permission of the copyright owner except for permitted fair dealing under Copyrights Designs and ...

Страница 3: ...3 Baxi Heating UK Ltd 2009 CONTENTS 1 0 General Information 4 2 0 Introduction 5 3 0 Operating the Appliance 6 4 0 Other Information 9 5 0 Notes 11 Section Page ...

Страница 4: ...of the unit and an explanation of the controller s icons and functions Defrosting of the Unit Occasionally frost will form on the rear of the unit across the finned heat exchanger This is a normal function of the Heat Pump s operation and should not cause concern to the user This function is performed automatically by the unit as and when necessary During the defrosting phase water vapour may be s...

Страница 5: ...re heating in your home For every unit of electrical energy used several units of heat are delivered So relating the energy purchased to the energy delivered heat pumps are extremely efficient 2 2 Domestic Hot Water 1 Please note that an auxiliary source of heat is required for your domestic hot water such as an electric immersion heater for example 2 3 Electrical Heater 1 When the outside tempera...

Страница 6: ...essure is below this top up the system using the filling point provided If you are unsure of its position or cannot identify it contact your installer who fitted the Heat Pump 3 2 Operating the Time and Temperature Controller 1 The Baxi AmbifloTM Heat Pump has been configured to work at its optimum efficiency by your commissioning engineer and the external settings should not be altered 2 The heat...

Страница 7: ...o be individually set as the timings cannot be copied across 7 If a second heating zone is part of the system turn the Aquaset dial to Z2 Fig 2 item 9 and repeat the above procedure for heating Zone 2 3 6 Adjustment of the Return Water Temperature to compensate for excessive heating or cooling 1 Turn the dial on the Aquaset controller to the OFF position Fig 2 item 6 2 Press and hold the and butto...

Страница 8: ... tiio on ns s a an nd d d do o n no ot t iin nd diic ca at te e a a f fa au ullt t A A f flla as sh hiin ng g d diis sp plla ay y w wiit th ho ou ut t a an n a alla ar rm m c co od de e iin nd diic ca at te es s t th ha at t t th he e w wa at te er r r re et tu ur rn n t te em mp pe er ra at tu ur re e iis s b be ello ow w t th he e m miin niim mu um m s sa af fe e v va allu ue e C Co on nt ta ac ...

Страница 9: ...nt of a fault 3 The pipework between the heat pump and the property can be hot The installer should have insulated these pipes This insulation is important for the safe operation of the unit so in the event of any damage contact your installer to arrange a repair Do not stand on the pipes around the Heat Pump unit as injury or damage may occur 4 If the electrical supply for the heat pump system is...

Страница 10: ...it will be necessary to show that the routine maintenance has been carried out in accordance with the requirements specified in the Installation Instructions Failure to maintain the system may invalidate your warranty 4 5 Disposal 1 This unit must not be crushed or incinerated 2 The Baxi AmbifloTM Heat Pump contains a number of components that must be disposed of under controlled conditions Under ...

Страница 11: ...11 5 0 Notes Baxi Heating UK Ltd 2009 ...

Страница 12: ...ements in our products which may affect the accuracy of the information contained in this leaflet All goods are sold subject to our standard Conditions of Sale which are available on request BAXI A Trading Division of Baxi Heating UK Ltd 3879156 A Division of Baxi Group Brooks House Coventry Road Warwick CV34 4LL Service support and Technical support 0844 871 1568 Website www baxi co uk e oe ...

Отзывы: