CERAMIC FUEL EFFECT REFITTING
The installer and owner guide for the ceramic fuel effect is separate from this guide. The
installer may have attached it to this guide or placed it inside. It is important that the
installer and owner guide for the ceramic fuel effect is followed correctly. If replacing
the ceramic fuel effect, where a new guide is supplied, follow the installer and owner
guide supplied with the replacement fuel effect.
Keep the replacement installer and owner guide with this owner guide for future
reference.
MAINTENANCE
Battery replacement.
The igniter unit uses a 9V PP3 battery. To replace the
battery remove the firefront casting / front cover
casting.
1. Remove and discard the battery from the ignition
block located below the burner tray at the left side.
2. Fit the replacement battery to the ignition block.
(See figure 4). The positive terminal (+) is to the top
as you insert.
3. Replace the firefront casting / front cover casting.
Regular maintenance.
In order to achieve and maintain high levels of personal safety and performance
efficiency, it is essential that the opening at the back of the fire and the flue are kept
clear of any form of obstruction. It is possible that deposits of mortar or soot could fall
and accumulate causing the flue to be blocked or restricted and so preventing proper
clearance of dangerous exhaust fumes.
In the United Kingdom it is the law that a landlord must have any gas appliance, flue
and pipework which is situated in a tenant’s premises checked for safety at least every
twelve months by a competent person (In the U.K, a CORGI registered installer).
We recommend that all gas appliances and their flues, wherever situated, are checked
annually.
Page 9
OWNER GUIDE
Figure 4. Fitting the battery