the pilot ignition position). The main burner should now light. Depress the control knob
slightly to release from the ‘HIGH’ position and turn back (clockwise) to ‘LOW’. While
turning, the burner flames should gradually become lower but remain alight. Depress
the control knob slightly to release from the ‘LOW’ position and turn back (clockwise)
to the Pilot ignition position. The main burner should extinguish but the pilot should
remain alight. Depress the control knob slightly and turn back (clockwise) to turn OFF.
This will extinguish the pilot.
14.2 Check for spillage.
1.
Close all doors and windows in the room
containing the appliance.
2.
Light the appliance and set the control to the
‘High’ position.
3.
Leave the appliance on for five minutes.
4.
The smoke match should be placed horizontally
into the hotbox at the right hand side (See figure
25).
The installation is satisfactory if the smoke is drawn
into the appliance.
If the smoke is not drawn into the appliance leave
the appliance alight at the maximum setting for a
further ten minutes and then repeat the test. If the
smoke is still not drawn into the appliance inspect
the sealing to the fireplace surround. If the sealing
is satisfactory but the appliance is installed with the
flue restrictor (See section 9 point 6) remove the
restrictor, reseal the appliance and retest. If smoke
is still not drawn into the appliance
disconnect the appliance and seek expert advice.
5.
If the above test is satisfactory open all internal connecting doors, hatches, etc. in the
room. Keep all doors and windows that open to the outside of the building closed.
Recheck for spillage as above. If an extractor fan is installed in the same room as the
appliance or a connecting room, check that spillage does not occur with the fan
operating and all doors and other openings between the fan and the appliance open.
If the smoke is drawn into the appliance, continue with the installation. If the test is not
satisfactory
disconnect the appliance and advise the customer of the cause of
failure
.
Page 26
INSTALLER GUIDE
©
Baxi Heating U.K. Limited 2007.
Figure 25. Smoke match tube
position (Fascia may differ from
that shown)
A spillage check must be made before leaving the installed appliance with the
customer. Make this with all the ceramic fuel effect pieces in position
.