The main burner should extinguish but the pilot should remain alight. Depress the
control knob slightly and turn back (clockwise) to turn OFF.
This will extinguish the pilot.
11.4 Check inlet pressure.
The appliance is pre-set to give the correct heat input
at the inlet pressure shown in section 2 of this
manual. No adjustment is necessary.
1.
Check the inlet pressure by fitting a pressure
gauge at the test point. The test point is on the inlet
‘T’ connector (See figure 22). Check the pressure
with the appliance alight and set at maximum output.
2.
After checking, turn off the appliance. Remove
the pressure gauge and replace the test point sealing
screw.
3.
Relight the appliance. Turn to the maximum
output position and test around the sealing screw for
gas soundness with a suitable leak detection fluid.
12. FASCIA INSTALLATION
12.1 Fitting the fascia.
1.
Unpack the fascia. Carefully lift the fascia. Place the
fascia against the fireplace front surface so that the four
retaining plates at the back of the fascia are directly
above the four retaining brackets of the hotbox. There
are two at the top of the hotbox and two to the side of
the burner module. Do not lift the fascia too high as the
bottom of the fascia will foul against the control knob.
Lower the fascia unit making sure that the retaining
plates locate fully into the brackets on the hotbox (See
figure 23).
Page 24
INSTALLER GUIDE
©
Baxi Heating U.K. Limited 2007.
Figure 23. Fascia location
Figure 22. Pressure test point