background image

Safety First.

Baxi Fires Division fires are CE Approved and designed to meet the appropriate British

Standards and Safety Marks.

Quality and Excellence.

All Baxi Fires Division fires are manufactured to the highest standards of quality and

excellence and are manufactured under a BS EN ISO 9001 quality system accepted by

the British Standards Institute.

The Highest Standards

Baxi Fires Division is a member of the Society of British Gas Industries which works to

ensure high standards of safety, quality and performance.

Careful Installation

Baxi Fires Division is a CORGI registered company. All our gas fires must be

installed by a competent CORGI Registered Installer in accordance

with our Installer Guide and should not be fitted directly on to a

carpet or floor of combustible material.

Page 3

OWNER GUIDE

© 

Baxi Heating U.K. Limited 2006.

Содержание 750

Страница 1: ... appliance to be operated and maintained satisfactorily However if further information is required our Baxi Fires Division Technical Helpline will be pleased to help Telephone 08706 061 065 National call rates apply in the United Kingdom In the Republic of Ireland Telephone 0044 8706 061 065 This guide is intended to help you care for your Baxi Fires Division gas fire Please read thoroughly before...

Страница 2: ...ess The Company Secretary Baxi Heating UK Limited Pentagon House Sir Frank Whittle Road Derby DE21 4XA Warning Any person who does any unauthorised act in relation to a copyright work may be liable to criminal prosecution and civil claims for damages Baxi Fires Division Erdington Birmingham B24 9QP www firesandstoves co uk Because our policy is one of constant development and improvement details m...

Страница 3: ...y the British Standards Institute The Highest Standards Baxi Fires Division is a member of the Society of British Gas Industries which works to ensure high standards of safety quality and performance Careful Installation Baxi Fires Division is a CORGI registered company All our gas fires must be installed by a competent CORGI Registered Installer in accordance with our Installer Guide and should n...

Страница 4: ...eramic fuel effect and rear wall 9 Burner 10 CERAMIC FUEL EFFECT REFITTING 10 MAINTENANCE 10 Regular maintenance 10 Servicing 11 USEFUL TELEPHONE NUMBERS 11 This gas fire is designed to meet the most stringent quality performance and safety requirements to provide you with many years trouble free service This guide aims to improve your understanding and appreciation of your gas fire by providing s...

Страница 5: ...od or other combustible material where the shelf is not more than 150mm deep For a shelf deeper than 150mm add 12 5mm to the clearance for every 25mm of additional shelf depth See graph1 Do always use a fireguard complying with BS 8423 for the protection of young children the elderly the infirm or pet animals Do wait three minutes before attempting to relight if the fire is switched off or the Pag...

Страница 6: ...you are altering the room Don t hang clothing towels or any other fabrics over the fire Don t put more ceramic fuel effect pieces on the fire than the number given in this guide or use any ceramic fuel effect pieces other than those authorised for this fire Incorrect combustion could result Don t put paper or other materials onto your fire Don t use the fire with damaged base ceramics Don t place ...

Страница 7: ... The device will also automatically shut off the gas supply to the fire if the pilot flame goes out due to lack of oxygen or for any other reason If this device starts to repeatedly shut off the gas get expert advice This device incorporates a probe which senses that the heat from the pilot flame is correct If this probe is cool the device will prevent any gas flow unless the control knob is kept ...

Страница 8: ...es and then repeat the ignition procedure Lighting the main burner Once the pilot light is established the main burner can be lit by depressing and turning the control knob anticlockwise to the High position Selecting the heat setting In order to change from one setting to another depress the control knob slightly and turn the knob to the required position Any setting from Low to High may be selec...

Страница 9: ...urther use Metal parts Clean the metal parts with a slightly damp lint free non abrasive cloth and then dry Do not use abrasive cleaners as these will scratch the fire surface Fascia Clean the metal parts with a slightly damp cloth and then dry If this does not work apply a very small amount of baby oil to a lint free non abrasive cloth and wipe over the surface Use a clean cloth to wipe off the o...

Страница 10: ...llowed correctly If replacing the ceramic fuel effect where a new guide is supplied follow the installer and owner guide supplied with the replacement fuel effect Keep the replacement installer and owner guide with this owner guide for future reference MAINTENANCE Regular maintenance In order to achieve and maintain high levels of personal safety and performance efficiency it is essential that the...

Страница 11: ...e available nationwide via the interpart stockist network For your local stockist consult Yellow pages under Central Heating When fitting replacement parts it is important that only approved parts are used for maximum safety USEFUL TELEPHONE NUMBERS General advice about gas and your gas fire BAXI FIRES DIVISION TECHNICAL HELPLINE 08706 061 065 To report faults or arrange for your fire to be servic...

Отзывы: