PTW-983IR
Outdoor 23X Optical Zoom Long Range Day / Night
IR PTZ Dome Camera
Notice: Read this Manual carefully before installation and keep it for future reference.
User Manual
Precautions:
Non-technician is forbidden to operate this dome device before reading this manual thoroughly.
Cut the power supply off before operating the dome device to avoid damage caused by improper operation.
Interior of the dome device are precision optical and electrical device. Heavy pressure, shock and other incorrect operations
should be prevented. Otherwise, may cause damage on product.
Please do not remove and disassemble any internal parts of dome video camera by self in order to avoid normal usage being
impacted. There is no part inside the device, which can be repaired by users themselves.
All the wiring of the dome device should be conducted strictly according to the wiring instruction. When necessary,
thunder-proof, surge-proof and other protecting measures should be carried out.
Please do not use the product under the situations of exceeding specified temperature, humidity or power supply specifications.
1.
2.
3.
4.
5.
6.
Chapter 3 Menu Setting
2.9
Complete the Test (Summary)
3.1
Operation Instructions
3.2
Main Menu
3.3
Dome information
3.4
Display Options
3.5
Control Options
3.4.1
Camera Name Setup
3.5.1
Dome Add Setup
3.5.2
Control Option Operation
3.6
Camera Options
If you have achieved control of the dome device as described in section 2.7 above, the system is basically normal. Do not change
the wiring or the applied settings to prevent from failure and loss.
If the dome does not respond to the command or only partial functionality is achieved, verify the wiring connections (section 2.1
and 2.4) and communication setting (section 2.2, 2.3 and 2.6) carefully.
To make a selection, move the joystick in the Up or Down direction. The on-screen arrow points to the selected option. Using the
joystick to the Left or Right position you can change the value of your selection or enter the submenu for the selected option. Press
the button CLOSE on the keyboard controller to exit the menu or return to the previous menu(one layer up)
Number setup.
95+SHOT+ACK to enter the main menu of the dome as illustrated down
Set the display of dome info or function
Set Auto Flip
、
Auto Focus
、
Auto AE, etc Move the joystick left / right or press
OPEN to enter control options
Move the cursor to select Auto Flip / Proportional Speed / Pan Reverse / Tilt Reverse / Vector Scan Still /
Vector Scan AF/+2 Tilt Limit / Speed Limit.
Move the joystick left / right or press OPEN to Display on / off / PTZ / Z / OFF
1. Auto Flip: If the camera lens auto rotates pan 180° then tilt 10° to auto track forward when the lens goes down tilt 90°.
2. Auto AE: If the camera is AE when the dome device changes its pan or tilt or zoom.
3. Vector Scan AF: If the camera AF when vector scan is running.
4. Speed Limit: the moving speed of dome device matching the video ratio to lower the speed.
Set the camera name
1. Joystick Left or Right when programming to select preset.
2. Press OPEN to confirm, open and display the number selection cursor
3. Joystick Left or Right to select the number to be entered
4. Press OPEN to confirm selection. The selected number is displayed on the corresponding data bit.
5. Number of respective data bits are input as above.
6. Press CLOSE to exit or return to the previous menu level when programming is done.
Menu operation instruction
Impedance Matching Setting
Protocol Setting
Baud Rate Setting
On / Off dip switch
1.1
Chapter 1 Product Overview
Chapter 2 Basic Configuration
Performance Instructions
2.2
Setting Protocol and Baud Rate of Dome Device
2.3
Setting Dome Device Address
2.5
Camera Installation
2.4
Impedance Matching Setting
2.6
Startup the Power Supply of the Dome Device
1.2
Feature Functions Instruction
2.1
Integrated Connection of Multiple Dome
DOME #1
DOME #2
DOME #N
RS - 485
Display
Display
Display
CONTROLLER / DVR / DVS.etc
AC24V POWER
AC24V POWER
AC24V POWER
RS485
RS - 485
RS - 485
On / Off Status
2nd digit
3rd digit
4th digit
5th digit
6th digit
7th digit
Protocol Type
PELCO-D
PELCO-P
Auto Detect
ON
OFF
OFF
ON
OFF
OFF
OFF
ON
OFF
**
**
**
OFF
OFF
OFF
**
**
**
Address of dome device is from 0 - 255. The number (address) of dome device in the control system is setup by the hardware (8 - digit on
and off switch) of dome device.
Integrated multi-protocol and auto protocol differentiation. Note: The dome device only auto differentiate controller of the first communication.
Pan 360 degree continuous scanning.
Tilt 90 degree action plus 2 degree angle adjustment. Plus the 2 degree adjustment, the view angle can be 90 or 92 degree.
Pan manual operation speed can be 0.1 to 150 degree per second.
Tilt manual operation speed can be 0.1 to 55 degree per second.
128 pre shot positions.(A fixed position that aimed by the dome camera, which can be set and revised by user arbitrarily)
The maximum running speed when pre shot is being called can reach 240 degree per second with accuracy of ± 0.1 degree.
Power supply: AC 24V / 3A.
Easy installation interface.
Pass environmental protection grade IP66 (outdoor type).
Adopts long distance RS-485 transmission mode.
Transmission speed, i.e. Baud rate is selectable. (Set by the sixth and seventh bit of the on and off switch of the dome device.2400bps - 19200bps)
1.
2.
3
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
English and Chinese operation menu and function display.
Camera name and operation position and angle display. (The name of the camera can be edited and the coordinate angle of the
dome device can be displayed on the screen.)
Operation crosshair function. (Enable this option, the target can be captured more effectively with crosshair on the screen.)
Three PTZ tours operation with 8 minutes record of each tour. (Can real-time monitor and record the action of manual operation)
Six group of programmable vector scans.(including scan speed, dwell time, pre shot and interruption between tours)
Auto flip function with 10 degree move up.
24 sectors of programmable sectional mask. (Can mask part of the sectors of camera, which differs depending on different types of camera)
8 sectors of programmable sectional display. (Can display the name and nature of concrete position shooting by the camera)
Auto enter function running after self-test of the dome device and auto enter function running when there is no transmission.
(Dwell time can be set from 5 to 999 seconds)
Freeze video picture function. (frozen picture function)
Operation return function. (after executing operation return, the dome device will return to the previous operation)
Intelligent manual scan function. (execute this function in manual pan operation, you can adjust the manual pan operation)
Intelligent power off real time memory. (If power is cut off when a certain function is in operation, the dome device can resume
working at where the power is cut off.)
High efficient 3-dimension scan.
Camera zoom in speed limit function. (When it is zooming in, the speed of the dome device will auto slow down.)
Remote setting of dome address.
Utilizes the world's most advanced high-power infrared LED technology.
a. Infrared LEDs have a high energy-conversion efficiency, low heat, long life, low power consumption of less than 5 watts,
overcoming the LED limitation of fading.
b. Variable angle infrared LEDs were developed utilizing its single point high power characteristic to act as a spot light source. Angle
will be adjusted according to the change in camera angle. This ensures that no infrared light is wasted and eliminates torch effect to
maximize the utilization of infrared lights, overcoming the tradition of the need to use large infrared LEDs of higher power
consumption for long distances.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
When system connection for multiple domes is performed, lightning arresters, video matrix, DVR video recorder, alarm, and other additional
devices can be embedded as per user’s actual situation, to realize system integration.
AC24V: Power supply of dome (power supply of 110V / 60HZ or 220V/50HZ input converted to 24V AC output)
RS-485Bus: The output of control signal (RS-485 signals) from the controller connected to the corresponding input of the dome
Video: The video output signal of dome (1Vp-p75 ohm)
(The output signal can be directly connected to video device such as display terminals or video matrix. Take the caution in the
impedance matching)
Wiring Diagram for multiple domes:
Before installation and use, the unique address for each dome and the communication protocol including transmission speed
(baud rate) should be set to correspond with the chosen control system. The dome must be power cycled after each change.
Setting method: The sum of switch numbers at ON position is the address of dome device.
Note
: 1. Make sure the proper connection of flat flex ribbon that connects the camera module to the dome device.
2. Different camera models may have different secured positions of the hole.
Self-detecting of the dome device (rotating) and the camera (displaying dome info) starts when startup the power supply.
Note: The dome device will firstly make tilt action for around 2-5 seconds when start self-detecting, then be blocked and
make a “click” sound that is normal as the dome is performing vertical positioning.
2.7
Controller Setting
2.8
Start Testing
Set the protocol, baud rate, and address of the keyboard controller to match the settings on the dome. (For instructions of
how to set the keyboard communication settings please refer to keyboard controller manual).
Attention: If the protocol setting of the dome is set to auto detection, the protocol of keyboard controller can be set
arbitrarily. But its baud rate should be set identical with that of the dome device.
(Please refer to the section on Camera Installation for more details on this operation)
When all of the above settings are completed you can start testing dome functionality.
On / Off Status
6th digit
7th digit
Baud Rate
2400
4800
9600
19200
OFF
OFF
ON
ON
OFF
ON
OFF
ON
This figure shows protocol of PELCO-D, Baud rate of 2400.
1. Move the joystick up / down to move the cursor to
2
4 1 6
ON
1 2 3 4 5 6 7 8
Matching numbers
(2+4+16=22) The address is 22
128
64
32
16
1
2
4
8
ON
1
2 3 4 5 6 7
8
Dome #N
RS 485
Dome device range: 0 - 255
The directions (up, down, left and right) of the
dome device can be controlled by using the
keyboard controller, as indicated in the figure.
Note: the working of dome device is normal
Zooming of the camera can be controlled by
zooming function Joystick or by using TELE (zoom
in) and WIDE (zoom out) buttons on the keyboard.
Note: The camera and dome device are normal
1. Direction control test of dome device
2. Zooming control test of camera
Up
Down
Right
Left
Joystick
Zoom in
Zoom out
J
o
y s ti
c
k
R
o
ta
te
IR-006
CAMERA : xxxx
PROTOCOL : xxxx
BAUDRATE : xxxx
DOME NO. : xxx
VERSION : xxx
IRIS CLOSE TO EXIT
1. Language Setup
Language: English and Chinese.
2. Dome Information
Joystick down to move the cursor to press OPEN or joystick left or right to move the
joystick to enter the menu.
3. Display Options
Display dome info or function.
4. Control Options
Set the pan or tilt of the dome manually or auto compatible with the entire control
system. User individualized operation setting.
5. Camera Options
Set camera function.
6. Function Programming
Program and execute PTZ and Vector Scan etc.
7. SYSTEM SETUP
System setup, Including restore defaulter setup clear memory, color system, dome reset
Joystick down to move the cursor to
press OPEN or joystick left or right to
move the joystick to enter the menu
Operation steps:
1. Joystick up / down to move the cursor to select Display Options
2. Joystick left / right to enter Display Option
3. Joystick up / down to select either one of the sub-menu
4. Joystick left / right to select ON / OFF
1. Joystick left / right to setup the add type. add type through Physic / Logic.
2. Joystick left / right to change the dome ID (only when add type selects logic).
3. Joystick left / right to setup the broadcast ID ON / OFF.
1.NAME
[1] Move the joystick up / down to move the cursor to select the Name.
[2] Move the joystick left / right or press OPEN to enter name editing menu.
[3] Move the joystick left / right to select “A - Z/0 - 9”, press “OPEN” to confirm,
press “CLOSE” to change or exit.
IR-006
1 CAMERA NAME SETUP
2 COORDINATES ON
3 START_UP SCR MSG ON
4 CROSSHAIRS ON
CAMERA NAME SETUP
1 NAME ___________
2 NAME DISPLAY OFF
PLEASE ENTER:
WELCOME________
ABCDEFGHIJKLMN
OPQRSTUVWXYZ
0123456789_
IRIS OPEN WHEN DONE
IRIS CLOSE TO EXIT
6 VECTORSCAN STILL OFF
7 AUTO FOCUS PTZ
8 AUTO AE PTZ
9 VECTORSCAN AF OFF
10 -2 TILT LIMIT OFF
11 SPEED LIMIT OFF
IR-006
1 LANGUAGE ENGLISH
2 DOME INFORMATION
3 DISPLAY OPTIONS
4 CONTROL OPTIONS
5 CAMERA OPTIONS
6 FUNCTION PROGRAMMING
7 SYSTEM SETUP
CONTROL OPTIONS
1 DOME ADDR STETUP
2 AUTO FLIP ON
3 PROPORTIONAL SPD ON
4 PAN REVERSE OFF
5 TILT REVERSE OFF
DOME ADDR SETUP
1 ADDR TYPE PHYSIC
2 DOME ID 1
3 BROADCAST ID OFF
5. Camera Options
Camera Identification Setting
To Open and Exit the Menu screen
Exposure Setting
WDR/BLC Setting
Brightness setting
SENS-UP setting
1. Press [EXIT]
2. Use [up] or [down] button to select the [EXIT] then use [left] or [right] button to select a
mode
• RET: Return to the previous.
• TOP: Return to the CAMERA SETTING menu screen.
• END: Exit the setup menu.
Note: The setup menu will disappear after saving the current settings.
The MENU screen appears on the monitor.
Check the current settings on the menu.
• You can use the camera identification (CAMERA ID) to assign a number to the camera.
• You can set the exposure options using the EXPOSURE menu.
• Use WDR/BLC option to set the options
for BLC or WDR camera.
Select [EXPOSURE] option on the [CAMERA SETTING] menu.
Press [EXIT] button and the EXPOSURE menu appears.
• You can set the brightness level. (0-100)
1. Select [BRIGHTNESS] option.
2. Use [left] or [right] button to set the bright level.
• AGC (Automatic Gain Control) setting
• If pictures are not clear due to darkness, use for increase the sensitivity of picture.
If the images are too dark, change the maximum [AGC] value to make the images lighter.
1. Select [WDR/BLC] option.
2. Use [left] or [right] button to select a mode then press [EXIT].
1. Select [CAMERA ID] option on the [CAMERA SETTING] menu.
2. Use [left] or [right] to select a CAMERA ID (OFF, 1-255).
• WDR: Set the WDR limit. - WDR LIMIT: LOW
←→
MIDDLE
←→
HIGH
• BLC: Set the BLC limit. - BLC LIMIT: LOW
←→
MIDDLE
←→
HIGH
• HSBLC: Use for adjusting brightness the specific area of picture.
- AREA SETTING: Use [left] or [right] button to select a area then use [up]or [down]
button to select a ON or OFF. Press [EXIT] to exit the Area setting menu.
- GRAY SCALE: Use [left] or [right] button to select a gray scale.
(GRAY
←→
D.GRAY
←→
BLACK).
- USER SCALE: Use [left] or [right] button to select a bright level.(5 level)
1. Select [AGC] option.
2. Use [left] or [right] button to select a mode.
(OFF
←→
LOW
←→
MIDDLE
←→
HIGH)
1. Use [up] or [down] button to select [SENS-UP] option.
2. Use [left] or [right] button to select a [AUTO].To setting the [AUTO] funtion, select the
[AUTO] on the [SHUTTER].
3. Press and use [left] or [right] button to set the SENS-UP limit (x2~x128).
Note: If you set to one of the SHUTTER options except AUTO on the
[SHUTTER] menu, the [SENS-UP] setting is not available and [---] mark is displayed.
• ATW (Auto-Tracing White Balance): The color temperature
range for the proper white balance is approximately 1700 - 11000K. Proper white
balance may not be obtained under the following conditions:
Setting the WB (White Balance) Mode
• You can select one of three modes for white balance adjustment.
1. Select [WHITE BAL] option.
2. Use [left] or [right] button to select one of three modes for white balance then press
[EXIT].
1) The color temperature is out of the 1700 - 11000K range.
2) When the scene contains mostly high color temperature objects, such as a blue sky
or sunset.
3) When the scene is dim.
• AWC
→
PUSH: If you select the AWC
→
PUSH mode, you will be able to set up the
White Balance automatically using [EXIT] button.
White Balance Setting
• MANUAL: You can set the white balance options manually.
- COLOR TEMP: Use [left] or [right] button to select a funtion.
(INDOOR: 3200, OUTDOOR: 5100)
- RED: Obtains the optimum amount of red gain.
- BLUE: Obtains the optimum amount of blue gain.It is a function of a color camera to delete
the filter with the IR Cut function in an illumination below the standard value so that it has a
better sensitivity.
• If you set the AGC to [OFF] or the SHUTTER is set to one of the SHUTTER options
except AUTO on the [EXPOSURE] menu, the AUTO mode of the DAY/NIGHT function
is not available and [---] mark is displayed.
• EXT : Switches between color picture and black-and-white picture ,when an external
day/night switching signal is received.
• DAY: Color mode enabled.
• NIGHT: Black-and-white mode enabled.
Note:
The motion detection detects the moving objects in the scene by monitoring changes
in brightness level. You can select the level of sensitivity for motion detection to 4
zone.
1. Select [MOTION DET] option.
2. Use [left] or [right] button to select a [ON] and press [EXIT] . The MOTION
DETECTION menu appears.
3. Use [left] or [right] button to select a zone number (AREA1~AREA4) on the
[ZONE NUMBER].
4. Use [left] or [right] button to set up the ON or OFF on the ZONE STATE.
5. Use [up] or [down] to select an option then use [left] or [right] button to adjust
the option.
Motion Detection Setting
Day/Night Setting
1. Select [DAY/NIGHT] option.
2. Use [left] or [right] button to select mode for day/night function.
• AUTO: You will be able to change the Day/Night mode automatically.
- LEVEL: Use [left] or [right] button to select a level. (LOW
←→
MIDDLE
←→
HIGH)
- DWELL TIME: Use or button to select a dwell time. (5, 10, 15 sec.)
• HEIGHT: Enlarge or decrease the vertical size of the mask.
• WIDTH: Enlarge or decrease the horizontal size of the mask.
• MOVE X: Moves horizontal position of the mask.
• MOVE Y: Moves vertical position of the mask.
6. Use [SENSITIVITY] option to achieve the optimum detection level. This is used
to reduce picture noise when the environment is too bright.
3D-DNR Setting
1. Select [3D-DNR] option.
2. Use [left] or [right] button to select an option.
(OFF
←→
LOW
←→
MIDDLE
←→
HIGH)
Note: If you set the AGC to [OFF] on the [EXPOSURE] menu, the [3D-DNR]
function is not available and [---] mark is displayed.
Privacy Setting
• This function is used for blocking out designated regions for privacy protection.
User may select up to 8 regions of any size and location.
1. Select [PRIVACY] option.
2. Use [left] or [right] button to select [ON] and press [EXIT]. The PRIVACY SETUP
menu appears.
3. Use [left] or [right] button to select a mask (AREA1~AREA8) on the
[MASK NUMBER].
4. Use [left] or [right] button to set up the ON or OFF on the DISPLAY option.
5. Use [left] or [right] button to set up the GRAY, WHITE or BLACK on the COLOR option.
6. Use [up] or [down]select an option then use [left] or [right] button to adjust the option.
• HEIGHT: Enlarge or decrease the vertical size of the mask.
• WIDTH: Enlarge or decrease the horizontal size of the mask.
• MOVE X: Moves horizontal position of the mask.
• MOVE Y: Moves vertical position of the mask.
Special Menu Settings
D-ZOOM
• This menu lets you adjust and set up D-ZOOM, D-EFFECT, SHARPNESS, COLOR,
SYNC, USER TITLE, and LANGUAGE functions.
1. Select [SPECIAL] option.
2. Press [EXIT] button and the SPECIAL menu appears. Setting the D-ZOOM (Digital
Zoom ) level You can select the digital zoom level.
1. Select [D-ZOOM] option on the [SPECIAL] menu.
2. Use [left] or [right] button to select [ON] then press [EXIT] the DIGITAL ZOOM
menu appears.
3. Use [up]or [down] to select an option then use [left] or [right] button to select a
level.
D-EFFECT
SHARPNESS
• To setup DIGITAL EFFECT:
• To setup DIGITAL ZOOM:
1. Select [D-EFFECT] option on the [SPECIAL] menu
2. Use [left] or [right] button to select a digital effect.
• V-FLIP: Flip the picture vertically.
• MIRROR: Turn on the mirror effect.
• ROTATE: Rotate the picture. (180°)
• OFF: Turn off the digital effect.
• To setup SHARPNESS effect:
1. Select [SHARPNESS] option on the [SPECIAL] menu.
2. Use [left] or [right] button to change a adjust the option.
• ON: Color screen
• OFF: B/W (Black and White) screen
COLOR
• To setup COLOR effect:
1. Select [COLOR] option on the [SPECIAL] menu.
2. Use [left] or [right] button to change a color effect.
• INT: Selects for using the internal synchronization.
• LL (Line Lock): Selects for the operation of multi cameras ,because it
synchronizes the camera phase by using the external signal (AC Signal).
A little phase deviation for some sets may be aligned.
SYNC
• For Synchronization(SYNC), you may select sync (INT) mode or line-lock (LINE) mode.
This function is only available with AC power source.
1. Select [SYNC] option on the [SPECIAL] menu.
2. Use [left] or [right] button to select [INT] or [LL] (Line Lock).
1. Select [USER TITLE] option on the [SPECIAL] screen.
2. Use [left] or [right] button to select a [ON] then press [EXIT] .The USER TITLE
menu appears.
3. Use [up] or [down] , [left] or [right] button to select a character or number.
- CLR: If you enter the wrong code, select CLR then press [EXIT].
- POS: Use [up] or [down] , [left] or [right] button to move position of USER TITLE
on the screen.
- END: Confirm your selection.
- A(Blank): Inserts a space at the cursor position.
-
←
/
→
: Moves cursor to left or right.
USER TITLE
• User Title allows a camera ID to be assigned to each camera using numbers (0-9) and
characters (A-Z, a-z).
• The USER TITLE is displayed on the upper left of the screen.
To remove the user title display, select [OFF].
1. Select [LANGUAGE] option on the [SPECIAL] screen.
2. Press [left] or [right] button to select a language.
Language
• To select language for the Setup Menu and On-screen Display:
SW2
Please configure impedance matching settings
according to position 1 of the diagram on the left.