Product information
PD-TaD 80
22 / 74
822-188-3
3.6.2
Connection cables
PD-TaD 80 integrated in the cable test van
Figure
Cable
Length Function
Protective earthing cable
Cross section: 16 mm
2
1.5 m
Is used to connect the PD-TaD to the protective earth
HV connection cables
(2 pcs)
0.7 m /
1.2 m
Are used to connect the PD-TaD to the test object
PoE cable (on hand
cable drum)
50 m /
80 m
Is used for the supply of power to the PD-TaD and for
data transmission
For the PD testing:
Calibrator connection
cables
Used to connect the calibrator to the PD test circuit
For the dissipation factor measurement:
tan-
δ cable (on hand
cable drum)
50 m /
80 m
Is used for data transmission during dissipation factor
measurements
VSE cables with 2
connection clips
(2 pcs)
1.5 m
Are used for the connection between the phases to be
tested at the far end (on the protective ring) and the
adjacent de-energised phase for the return of leakage
currents
VSE cables with Ø 4 mm
connector and a
connection clip
(2 pcs)
3 m
Is used for connections at the near end:
between PD-TaD and the phase to be tested (on
the protective ring)
between PD-TaD and the adjacent de-energised
phase for the return of leakage currents
Содержание PD-TaD 80
Страница 27: ...PD TaD 80 Technical data 822 188 3 27 74 4 TECHNICAL DATA ...
Страница 72: ...Index PD TaD 80 72 74 822 188 3 W Warranty and After Sales 65 ...
Страница 73: ......