Description/inspection of the safety and monitoring systems
Operating Instructions CANsync-Master Option Module for BM4-O-PLC BM4-O-CAN-06
Document No.: 5.02056.01A
Baumüller Nürnberg Electronic GmbH & Co. KG
30
6.3
6.3
Description/inspection of the safety and monitoring systems
Before you commission the CANsync-Master option module for b maXX, you must elim-
inate any errors/error messages that may be present on the b maXX 4400 unit. These er-
rors may be due to faulty assembly (e.g. defective cables) or faulty installation (e.g. no
power supply). You must not continue with commissioning until you have eliminated the
errors.
6.4
Description and inspection of the controls and displays
6.4.1
Sample Configuration
Figure 10:
b maXX with CANsync-Master in option slot G and PLC in option slot H
6.4.2
LEDs
RJ45 socket X1 has two LEDs (one green and one red); from now on, they will be referred
to as H1 and H2. The LEDs have different meanings during initialization and during oper-