Description and inspection of the operation and display elements
Operation Manual
b maXX safe PLC
BMC-M-SAF-02
Document no.: 5.07020.04
Baumüller Nürnberg GmbH
64
11.7
Once the fourth address is confirmed, the address will be overtaken and will enter into
effect after the next restarting.
The entry is aborted if you stop pushing button S1 on channel 2 of the PLC and button S1
on the power supply. After a defined maximum time (10 seconds), the entry mode will be
exited and the address which was previously set will remain.
The position of the rotary switch need not correspond to the set station address at all
times, since a turn of the rotary switch outside of entry mode will not be overtaken.
As long as the entry mechanism is not activated, the current station address overtaken
will always scroll to the H5 7-segment display on channel 2 of the PLC with a brief inter-
ruption to recognize the initial position. In the process, the decimal point will always light
up at each second digit, so that sequential identical digits can be recognized at the turning
of the decimal point (for instance, 1.2 2.4 means 1224). Initial digits which are zero are
not displayed.
You can find additional information on the meaning of the station number and address/ID
allocation in the
>
Application Manual b maXX safe PLC
<
.
11.7 Description and inspection of the operation and display elements
11.7.1 LEDs for displaying the operation statuses of the BMC-M-SAF-02 (channel 1)
The display elements on the b maXX safe PLC module consist of twelve LEDs on channel
1: five green (H1, H3, H5, H7, H11), five red(H2, H4, H6, H8, H10), one blue (H9) and one
orange/green (H12) (see “F” in
The LEDs are used during the initialization (run-up phase) of the operation system of the
b maXX safe PLC.
During operation (after the operating system’s run-up phase), the LEDs can be used by
the user in the application program on the b maXX safe PLC (standard PLC).
After the power is turned on, all system components in the b maXX system will have to
have reached a certain internal operation status (global ready message) before they can
be addressed by the b maXX safe PLC.
Figure 15:
LEDs on the b maXX safe PLC of the BMC-M-SAF-02
LEDs
H1
⊗
green
⊗
red
⊗
green
H4
⊗
red
H5
⊗
green
⊗
red
⊗
green
H8
⊗
red
H9
⊗
blue
⊗
red
⊗
green
H12
⊗
/
⊗
green/
orange
Содержание b maXX BMC-M-SAF-02
Страница 8: ...Operation Manual b maXX safe PLC BMC M SAF 02 Document no 5 07020 04 Baumüller Nürnberg GmbH 8 of 118 ...
Страница 16: ...Operation Manual b maXX safe PLC BMC M SAF 02 Document no 5 07020 04 Baumüller Nürnberg GmbH 16 of 118 ...
Страница 58: ...Operation Manual b maXX safe PLC BMC M SAF 02 Document no 5 07020 04 Baumüller Nürnberg GmbH 58 of 118 ...
Страница 82: ...Operation Manual b maXX safe PLC BMC M SAF 02 Document no 5 07020 04 Baumüller Nürnberg GmbH 82 of 118 ...
Страница 90: ...Operation Manual b maXX safe PLC BMC M SAF 02 Document no 5 07020 04 Baumüller Nürnberg GmbH 90 of 118 ...
Страница 92: ...Operation Manual b maXX safe PLC BMC M SAF 02 Document no 5 07020 04 Baumüller Nürnberg GmbH 92 of 118 ...
Страница 100: ...Operation Manual b maXX safe PLC BMC M SAF 02 Document no 5 07020 04 Baumüller Nürnberg GmbH 100 of 118 A ...
Страница 119: ......