![Baumuller b maXX BM5800 Скачать руководство пользователя страница 64](http://html.mh-extra.com/html/baumuller/b-maxx-bm5800/b-maxx-bm5800_parameter-manual_2711380064.webp)
Configuration
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
Baumüller Nürnberg GmbH
64
3.4
3.4.1.3 Description of the Parameters
129.3
Hardware Id
The hardware identifier has the format:
33.YYNN.BBA01
Example: 33.0815.02D04
130.1
Heat sink temperature
FLOAT
0
1000
0
°C
1:1
X
130.2
Interior temperature
FLOAT
0
1000
0
°C
1:1
X
130.3
DC link actual voltage
FLOAT
10
1000
10
V
1:1
X
130.8
Mains voltage
FLOAT
0.0e+0
1000
0.0e+0
V
1:1
X
130.9
Fan mode
UINT
0x0000
0x3
0x0001
1:1
X
130.10
Mode
UINT
0x0000
0xFFFF
0x0000
1:1
X
130.12
Heatsink temperature
warning threshold
UINT
0
0xFFFF
75
°C
1:1
X
130.13
Interior temperature
warning threshold
UINT
0
0xFFFF
55
°C
1:1
X
130.15
PWM frequency
UINT
2
16
8
kHz
1:1
X
X
130.18
I offset phase U
FLOAT
-2.56e+02
2.56e+02
0.0
A
1:1.414 X
130.19
I offset phase V
FLOAT
-2.56e+02
2.56e+02
0.0
A
1:1.414 X
130.20
I offset phase W
FLOAT
-2.56e+02
2.56e+02
0.0
A
1:1.414 X
130.24
Phase error delay time
UINT
0
65535
0
ms
1:1
X
130.25
Mains failure delay
UINT
0
6000
0
ms
1:1
X
130.28
Actual ground fault cur-
rent
FLOAT
0
100
0
A
1:1
X
130.29
Chopper threshold
FLOAT
300
780
780
V
1:1
X
X
130.34
Status STO module
UINT
0
0xFFFF
0
1:1
X
130.37
Udc threshold for mains
failure
FLOAT
10
1000
450
V
1:1
X
X
130.38
Udc hysteresis for
mains failure
FLOAT
10
500
50
V
1:1
X
X
130.40
Operation time
UDINT
0
0xFFFFFFFF 0
s
1:1
X
130.41
Actual PWM frequency
UINT
2
16
8
kHz
1:1
X
175.3
Max. device control
cabin temperature
UINT
0
55
40
Grad
C
1:1
X
X
175.4
Max. device altitude
UINT
0
5000
1000
m
1:1
X
X
175.5
Max. device mains volt-
age
UINT
0
530
400
V
1:1
X
X
175.6
Max. device DC link
voltage
UINT
0
760
540
V
1:1
X
X
175.7
PU max.continuous cur-
rent actual value
FLOAT
0
1000
4
A
1:1
X
175.8
PU I2t max. continuous
current actual value
FLOAT
0
1000
4
A
1:1
X
Содержание b maXX BM5800
Страница 10: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 10 of 814 Contents ...
Страница 724: ...Monitoring Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 724 of 814 3 11 ...
Страница 756: ...Error descriptions Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 756 of 814 4 5 ...
Страница 800: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 800 of 814 ...
Страница 808: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 808 of 814 ...
Страница 814: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 814 of 814 Notes ...
Страница 815: ......