3.8
3.8.6
Operating mode Position control
The cyclic synchronous position set value specification is activated through operating
mode
= -4. In this operating mode, the position set value that is transferred in
every fieldbus cycle is interpolated in the control cycle. The interpolated set value is the
position set value for the position control.
The major functions are:
m
Selection between two input channels for the position set value to be interpolated:
–
Set value in the format 16 Bit revolutions and 16 Bit angle
–
Set value in the format 32 Bit angle
m
Each of the two input channels has one offset input additionally:
–
Position offset in the format 16 Bit revolutions and 16 Bit angle
–
Angle offset in the format 32 Bit angle
m
and its positioning offset
can pass an additional
function block (
mode bit 6 = 1). In the following this function block refers to as
"Weighting" and contains these functions:
– Weighting function
The set value can be weighted by the
Rotation position resolution.
– Load gear
Furthermore an available load gear can be regarded by the parameters
Input revolutions and
Output revolutions.
– Modulo position set value
The set value can be used as modulo positioning set value. This function is activated
by
Modulo revolutions > 0.
For details refer to
Mode with bit 6 and
m
Additional input as offset speed
. The function can thereby be tested without
cyclical set value specifications through the fieldbus.
m
Optional speed actual value synchronization when activating the operating mode.
m
Optional extrapolation during set value failure.
m
Evaluation of software limit switches possible
Activation, refer to
.
m
Evaluation of hardware limit switches possible
Activation, refer to
m
Stop possible through control word bit 8 of the drive manager.
m
Set values can be blocked through the control word bit 11 of the drive manager.
m
Display of current output set values: Acceleration, speed and position.
m
Bipolar limiting of output speed through Parameter
.
m
Interpolation of the fieldbus set value for the cycle of the position control (
cycle time).
m
The set fieldbus cycle time
is used as the interpolation interval.
m
The interpolation interval can be extended through the factor in Parameter
Mode in bit 12 and 13. The following applies:
Interpolation interval = Factor * Fieldbus cycle.
Factors 1, 2, 4 and 8 are possible. From the factor value 2 onward the
divi-
sion ratio fieldbus task must have been set to 1!
m
PT
1
filter for smoothing the transferred position set value
m
An external, cyclical specification of the speed and acceleration feedforward values
takes place. For details see
,
and
.
Содержание b maXX BM5800
Страница 10: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 10 of 814 Contents ...
Страница 724: ...Monitoring Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 724 of 814 3 11 ...
Страница 756: ...Error descriptions Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 756 of 814 4 5 ...
Страница 800: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 800 of 814 ...
Страница 808: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 808 of 814 ...
Страница 814: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 814 of 814 Notes ...
Страница 815: ......