![Baumuller b maXX BM5800 Скачать руководство пользователя страница 578](http://html.mh-extra.com/html/baumuller/b-maxx-bm5800/b-maxx-bm5800_parameter-manual_2711380578.webp)
Operating Modes
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
Baumüller Nürnberg GmbH
578
3.8
120.4
Homing method
Selection of the homing method.
This parameter determines the procedure for the reference run. This includes the start di-
rection of the home position and evaluation of the reference initiator.
Value
Meaning
-10
Approaching the mechanical stop with zero pulse or encoder zero angle,
counterclockwise turn
-9
Approaching the mechanical stop with zero pulse or encoder zero angle,
clockwise turn
-8
Approaching the mechanical stop, counterclockwise turn
-7
Approaching the mechanical stop, clockwise turn
-6
Approaching the next encoder zero angle
-5
Approaching the positive limit switch (= 18)
-4
Approaching the negative limit switch (= 17)
-3
Setting the home position (= 35)
-2
Approaching the encoder zero angle or zero pulse with counterclockwise
turn (= 33)
-1
Approaching the encoder zero angle or zero pulse with clockwise turn (= 34)
0
Reserved
1
Negative limit switch with zero pulse or encoder zero angle
2
Positive limit switch with zero pulse or encoder zero angle
3
Positive zero point changeover switch with zero pulse or encoder zero angle,
counterclockwise turn
4
Positive zero point changeover switch with zero pulse or encoder zero angle,
clockwise turn
5
Negative zero point changeover switch with zero pulse or encoder zero
angle, clockwise turn
6
Negative zero point changeover switch with zero pulse or encoder zero
angle, counterclockwise turn
7
Zero point switch, left of Edge A, with zero pulse or encoder zero angle,
clockwise turn
8
Zero point switch, right of Edge A, with zero pulse or encoder zero angle,
clockwise turn
9
Zero point switch, left of Edge B, with zero pulse or encoder zero angle,
clockwise turn
10
Zero point switch, right of Edge B, with zero pulse or encoder zero angle,
clockwise turn
11
Zero point switch, right of Edge B, with zero pulse or encoder zero angle,
counterclockwise turn
Содержание b maXX BM5800
Страница 10: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 10 of 814 Contents ...
Страница 724: ...Monitoring Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 724 of 814 3 11 ...
Страница 756: ...Error descriptions Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 756 of 814 4 5 ...
Страница 800: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 800 of 814 ...
Страница 808: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 808 of 814 ...
Страница 814: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 814 of 814 Notes ...
Страница 815: ......