Operating Modes
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
Baumüller Nürnberg GmbH
518
3.8
121.3
Negative SW limit switch
This parameter limits the permitted traversing range with active software limit switch mon-
itoring in the negative direction (= negative output speed).
It indicates the lowest target position that can be approached in operating mode position
target entry.
In operating modes manual operation and position control, a stop occurs immediately if
there is a drop below the value with the adjusted stop delay (
).
121.4
Positive SW limit switch
This parameter limits the permitted traversing range with active software limit switch mon-
itoring in the positive direction (= positive output speed).
It indicates the greatest target position that can be approached in operating mode position
target entry.
In operating modes manual operation and position control, a stop occurs immediately if
the value is exceeded with the adjusted stop delay (
).
121.5
Positioning window
Operating mode position target specification (= 1) and spindle positioning (= -6): If the
drive reaches a window around the new target position, the "Position target reached" bit
will be set in the status word. The positioning window is symmetrical surrounding the tar-
get position and is determined with this parameter.
Operating mode reference run (= 6): The positioning window for standstill recognition is
used with Set Home Position.
Additionally the parameter is used in all position controlled operating modes for generat-
ing the "In Position" message (bit 6 in
Status). If the absolute value of
Position error rev+angle is less than the positioning window, the drive generates the mes-
sage "In Postion".
121.6
Positioning window time
This parameter is used to prevent that the "Position target reached" bit is set when the
briefly moving across the positioning window. The time during which the drive must be
located in the positioning window before "Position target reached" is set must be deter-
mined.
If the drive is pushed out of the positioning window again, such as through the load, "Po-
sitioning target reached" will be deleted again. The next dip into the positioning window
will restart time monitoring.
Содержание b maXX BM5800
Страница 10: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 10 of 814 Contents ...
Страница 724: ...Monitoring Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 724 of 814 3 11 ...
Страница 756: ...Error descriptions Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 756 of 814 4 5 ...
Страница 800: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 800 of 814 ...
Страница 808: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 808 of 814 ...
Страница 814: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 814 of 814 Notes ...
Страница 815: ......