Controllers
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
Baumüller Nürnberg GmbH
482
3.7
114.12
Minimal value reactive current
The output of the reactive current brake (
) can accept values between 0 and 1
and be limited by this parameter. With the value 0 the complete field current (
) can
be specified by the reactive current brake at synchronous machines; the reactive current
brake cannot apply any reactive current at value 1.