Description of the Software Modules and Parameters
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
353
3
3.6
Set Value Generators
3.6.1
Ramp function generator
The ramp function generator is used to generate rising or falling ramps in the Speed pre-
set 1 (
= 2) and Speed control (
= -3) speed-controlled operating
modes. Additionally, it is used for controlling braking procedures (Quick Stop, Drive Shut-
down, Inhibit Drive).
The ramp function generator has an input with separately adjustable ramp-up and ramp-
down times. Furthermore the ramp-down time for the Quick Stop function is separately
adjustable.
The input and output values for the ramp function generator are relative quantities
(±100 %) and are referred to the Maximum drive speed parameter (
).
The ramp slope for the acceleration and braking procedures is defined by the ramp-up
and ramp-down times. The times correspond to a 100 % change in the set value.
For additional rounding of the ramp-up or ramp-down ramps, a PT
1
element (smoothing)
with adjustable time constant is connected after the ramp function generator.
The ramp function generator provides the following control options via the control word
(
):
m
Inhibit ramp generator (set output permanently to 0, ramp-down at the current limit)
m
Stop ramp generator (freeze output value)
m
Inhibit ramp generator set value (set input internally to 0, ramp-down on the ramp-down
ramp)
The following options can additionally be selected via Ramp generator mode
:
m
Selection between a 16-bit parameter (
) or a 32-bit parameter (
input value for the ramp function generator.
m
Blocking of positive or negative set values.
m
Reversal of set value sign. The internal processing sequence is inhibit before sign re-
versal.
m
Switch-off of speed set value synchronization when activating the ramp function gen-
erator.
m
Adjustment of ramp shape:
n
Trapezoidal speed profile; stepped acceleration.
There is a possibility of smoothing the speed by means of a PT
1
element.
n
S-Curve with quadratic speed profile; trapezoidal acceleration.
m
Task selection to process the set values:
The set values of the ramp function generator can either be calculated in the RT1 task
(1 ms; default) or in the fieldbus task. The setting is made by bit 16 of the
mode.
m
Speed profile in zero-crossing at change of direction with or without rounding-off.
m
The set quick stop time
applies to
n
change of set value from 100% to 0%
Содержание b maXX BM5800
Страница 10: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 10 of 814 Contents ...
Страница 724: ...Monitoring Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 724 of 814 3 11 ...
Страница 756: ...Error descriptions Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 756 of 814 4 5 ...
Страница 800: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 800 of 814 ...
Страница 808: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 808 of 814 ...
Страница 814: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 814 of 814 Notes ...
Страница 815: ......