Commissioning
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
35
2
Altering motor
data
When using the Baumüller motor database, you will not find any discrepancies between
the motor data sheet and the data taken automatically from the database.
18
Click on "Motor" in the project tree.
Checking motor
data
19
You will find all the important motor data or parameters displayed in the Motor window
and the Synchronous Motor sub-window.
Check all data.
Figure 18:
ProDrive: Motor-General
NOTE
If you are using motors from third-party manufacturers, you can also include their
data in the motor database.